CVE-2025-48014
Improper Restriction of Excessive Authentication Attempts
Mitigation
- Upgrade SEL-5056 Software-Defined Network Flow Controller to 2.16.0 or later.
Who should check
- Anyone running Schweitzer Engineering Laboratories SEL-5056 Software-Defined Network Flow Controller < 2.16.0
Vulnerability facts
- Affected
- Schweitzer Engineering Laboratories SEL-5056 Software-Defined Network Flow Controller < 2.16.0
- Fixed in
- Schweitzer Engineering Laboratories SEL-5056 Software-Defined Network Flow Controller 2.16.0
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, no login needed
- CVSS
- 7.5 (v3.1, CNA)CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:NOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Privileges required: None
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: High
- Integrity impact: None
- Availability impact: None
- EPSS
- 0.80% chance of exploitation in 30 days (percentile 53, 2026-11-26)
- CWE
- CWE-307
- Modified
Description
Password guessing limits could be bypassed when using LDAP authentication.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Schweitzer Engineering Laboratories SEL-5056 Software-Defined Network Flow Controller | < 2.16.0 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2025-48014. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2025-48014.md Affected: Schweitzer Engineering Laboratories SEL-5056 Software-Defined Network Flow Controller < 2.16.0 Fixed in: Schweitzer Engineering Laboratories SEL-5056 Software-Defined Network Flow Controller 2.16.0 Steps: 1. Search this machine and project for Schweitzer Engineering Laboratories SEL-5056 Software-Defined Network Flow Controller: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2025-48014 being exploited?
There is no confirmed exploitation: CVE-2025-48014 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.80% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2025-48014?
High: CVSS 7.5 (v3.1, scored by CNA). Remote, no login needed.
Which versions are affected by CVE-2025-48014?
Schweitzer Engineering Laboratories SEL-5056 Software-Defined Network Flow Controller < 2.16.0.
Is there a fix for CVE-2025-48014?
Yes. Fixed in Schweitzer Engineering Laboratories SEL-5056 Software-Defined Network Flow Controller 2.16.0. Upgrade SEL-5056 Software-Defined Network Flow Controller to 2.16.0 or later.
How do I check if I'm affected by CVE-2025-48014?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.