CVE-2025-41749

HIGH 7.1EPSS 32%

Reflected XSS vulnerability in port_util.php

Mitigation

  • Upgrade FL SWITCH 2005 to 3.50 or later.
  • Upgrade FL SWITCH 2008 to 3.50 or later.
  • Upgrade FL SWITCH 2016 to 3.50 or later.
  • Upgrade FL SWITCH 2105 to 3.50 or later.
  • Upgrade FL SWITCH 2108 to 3.50 or later.
  • Upgrade FL SWITCH 2116 to 3.50 or later.
  • Upgrade FL SWITCH 2204-2TC-2SFX to 3.50 or later.
  • Upgrade FL SWITCH 2205 to 3.50 or later.

Who should check

  • Anyone running Phoenix Contact FL SWITCH 2005 >= 0.0.0, < 3.50
  • Anyone running Phoenix Contact FL SWITCH 2008 >= 0.0.0, < 3.50
  • Anyone running Phoenix Contact FL SWITCH 2016 >= 0.0.0, < 3.50
  • Anyone running Phoenix Contact FL SWITCH 2105 >= 0.0.0, < 3.50
  • Anyone running Phoenix Contact FL SWITCH 2108 >= 0.0.0, < 3.50
  • Anyone running Phoenix Contact FL SWITCH 2116 >= 0.0.0, < 3.50
  • Anyone running Phoenix Contact FL SWITCH 2204-2TC-2SFX >= 0.0.0, < 3.50
  • Anyone running Phoenix Contact FL SWITCH 2205 >= 0.0.0, < 3.50

Vulnerability facts

Affected
Phoenix Contact FL SWITCH 2005 >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2008 >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2016 >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2105 >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2108 >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2116 >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2204-2TC-2SFX >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2205 >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2206-2FX >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2206-2FX SM >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2206-2FX SM ST >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2206-2FX ST >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2206-2SFX >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2206-2SFX PN >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2206C-2FX >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2207-FX >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2207-FX SM >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2208 >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2208 PN >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2208C >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2212-2TC-2SFX >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2214-2FX >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2214-2FX SM >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2214-2SFX >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2214-2SFX PN >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2216 >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2216 PN >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2304-2GC-2SFP >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2306-2SFP >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2306-2SFP PN >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2308 >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2308 PN >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2312-2GC-2SFP >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2314-2SFP >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2314-2SFP PN >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2316 >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2316 PN >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2404-2TC-2SFX >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2406-2SFX >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2406-2SFX PN >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2408 >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2408 PN >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2412-2TC-2SFX >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2414-2SFX >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2414-2SFX PN >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2416 >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2416 PN >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2504-2GC-2SFP >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2506-2SFP >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2506-2SFP PN >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2508 >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2508 PN >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2512-2GC-2SFP >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2514-2SFP >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2514-2SFP PN >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2516 >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2516 PN >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2608 >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2608 PN >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2708 >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2708 PN >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2303-8SP1 >= 0.0.0, < 3.50; Phoenix Contact FL NAT 2008 >= 0.0.0, < 3.50; Phoenix Contact FL NAT 2208 >= 0.0.0, < 3.50; Phoenix Contact FL NAT 2304-2GC-2SFP >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2008F >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2316/K1 >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2506-2SFP/K1 >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2508/K1 >= 0.0.0, < 3.50
Fixed in
Phoenix Contact FL SWITCH 2005 3.50, Phoenix Contact FL SWITCH 2008 3.50, Phoenix Contact FL SWITCH 2016 3.50, Phoenix Contact FL SWITCH 2105 3.50, Phoenix Contact FL SWITCH 2108 3.50, Phoenix Contact FL SWITCH 2116 3.50, Phoenix Contact FL SWITCH 2204-2TC-2SFX 3.50, Phoenix Contact FL SWITCH 2205 3.50, Phoenix Contact FL SWITCH 2206-2FX 3.50, Phoenix Contact FL SWITCH 2206-2FX SM 3.50, Phoenix Contact FL SWITCH 2206-2FX SM ST 3.50, Phoenix Contact FL SWITCH 2206-2FX ST 3.50, Phoenix Contact FL SWITCH 2206-2SFX 3.50, Phoenix Contact FL SWITCH 2206-2SFX PN 3.50, Phoenix Contact FL SWITCH 2206C-2FX 3.50, Phoenix Contact FL SWITCH 2207-FX 3.50, Phoenix Contact FL SWITCH 2207-FX SM 3.50, Phoenix Contact FL SWITCH 2208 3.50, Phoenix Contact FL SWITCH 2208 PN 3.50, Phoenix Contact FL SWITCH 2208C 3.50, Phoenix Contact FL SWITCH 2212-2TC-2SFX 3.50, Phoenix Contact FL SWITCH 2214-2FX 3.50, Phoenix Contact FL SWITCH 2214-2FX SM 3.50, Phoenix Contact FL SWITCH 2214-2SFX 3.50, Phoenix Contact FL SWITCH 2214-2SFX PN 3.50, Phoenix Contact FL SWITCH 2216 3.50, Phoenix Contact FL SWITCH 2216 PN 3.50, Phoenix Contact FL SWITCH 2304-2GC-2SFP 3.50, Phoenix Contact FL SWITCH 2306-2SFP 3.50, Phoenix Contact FL SWITCH 2306-2SFP PN 3.50, Phoenix Contact FL SWITCH 2308 3.50, Phoenix Contact FL SWITCH 2308 PN 3.50, Phoenix Contact FL SWITCH 2312-2GC-2SFP 3.50, Phoenix Contact FL SWITCH 2314-2SFP 3.50, Phoenix Contact FL SWITCH 2314-2SFP PN 3.50, Phoenix Contact FL SWITCH 2316 3.50, Phoenix Contact FL SWITCH 2316 PN 3.50, Phoenix Contact FL SWITCH 2404-2TC-2SFX 3.50, Phoenix Contact FL SWITCH 2406-2SFX 3.50, Phoenix Contact FL SWITCH 2406-2SFX PN 3.50, Phoenix Contact FL SWITCH 2408 3.50, Phoenix Contact FL SWITCH 2408 PN 3.50, Phoenix Contact FL SWITCH 2412-2TC-2SFX 3.50, Phoenix Contact FL SWITCH 2414-2SFX 3.50, Phoenix Contact FL SWITCH 2414-2SFX PN 3.50, Phoenix Contact FL SWITCH 2416 3.50, Phoenix Contact FL SWITCH 2416 PN 3.50, Phoenix Contact FL SWITCH 2504-2GC-2SFP 3.50, Phoenix Contact FL SWITCH 2506-2SFP 3.50, Phoenix Contact FL SWITCH 2506-2SFP PN 3.50, Phoenix Contact FL SWITCH 2508 3.50, Phoenix Contact FL SWITCH 2508 PN 3.50, Phoenix Contact FL SWITCH 2512-2GC-2SFP 3.50, Phoenix Contact FL SWITCH 2514-2SFP 3.50, Phoenix Contact FL SWITCH 2514-2SFP PN 3.50, Phoenix Contact FL SWITCH 2516 3.50, Phoenix Contact FL SWITCH 2516 PN 3.50, Phoenix Contact FL SWITCH 2608 3.50, Phoenix Contact FL SWITCH 2608 PN 3.50, Phoenix Contact FL SWITCH 2708 3.50, Phoenix Contact FL SWITCH 2708 PN 3.50, Phoenix Contact FL SWITCH 2303-8SP1 3.50, Phoenix Contact FL NAT 2008 3.50, Phoenix Contact FL NAT 2208 3.50, Phoenix Contact FL NAT 2304-2GC-2SFP 3.50, Phoenix Contact FL SWITCH 2008F 3.50, Phoenix Contact FL SWITCH 2316/K1 3.50, Phoenix Contact FL SWITCH 2506-2SFP/K1 3.50, Phoenix Contact FL SWITCH 2508/K1 3.50
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Remote, no login needed
CVSS
7.1 (v3.1, CNA)CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:LOpen in CVSS calculator
Show all 8 CVSS metrics
  • Attack vector: Network
  • Attack complexity: Low
  • Privileges required: None
  • User interaction: Required
  • Scope: Changed (impact reaches other components)
  • Confidentiality impact: Low
  • Integrity impact: Low
  • Availability impact: Low
EPSS
0.46% chance of exploitation in 30 days (percentile 32, 2026-11-26)
CWE
CWE-79
Published
Modified

Description

An XSS vulnerability in port_util.php can be used by an unauthenticated remote attacker to trick an authenticated user to click on the link provided by the attacker in order to change parameters available via web based management (WBM). The vulnerability does not provide access to system-level resources such as operating system internals or privileged functions. Access is limited to device configuration parameters that are available in the context of the web application. The session cookie is secured by the httpOnly Flag. Therefore an attacker is not able to take over the session of an authenticated user.

Affected and fixed versions

Package / productAffectedFixedSource
Phoenix Contact FL SWITCH 2005>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2008>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2016>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2105>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2108>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2116>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2204-2TC-2SFX>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2205>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2206-2FX>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2206-2FX SM>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2206-2FX SM ST>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2206-2FX ST>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2206-2SFX>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2206-2SFX PN>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2206C-2FX>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2207-FX>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2207-FX SM>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2208>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2208 PN>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2208C>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2212-2TC-2SFX>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2214-2FX>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2214-2FX SM>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2214-2SFX>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2214-2SFX PN>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2216>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2216 PN>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2304-2GC-2SFP>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2306-2SFP>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2306-2SFP PN>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2308>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2308 PN>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2312-2GC-2SFP>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2314-2SFP>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2314-2SFP PN>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2316>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2316 PN>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2404-2TC-2SFX>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2406-2SFX>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2406-2SFX PN>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2408>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2408 PN>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2412-2TC-2SFX>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2414-2SFX>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2414-2SFX PN>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2416>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2416 PN>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2504-2GC-2SFP>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2506-2SFP>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2506-2SFP PN>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2508>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2508 PN>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2512-2GC-2SFP>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2514-2SFP>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2514-2SFP PN>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2516>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2516 PN>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2608>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2608 PN>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2708>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2708 PN>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2303-8SP1>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL NAT 2008>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL NAT 2208>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL NAT 2304-2GC-2SFP>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2008F>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2316/K1>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2506-2SFP/K1>= 0.0.0, < 3.50—cvelist
Phoenix Contact FL SWITCH 2508/K1>= 0.0.0, < 3.50—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2025-41749. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2025-41749.md
Affected: Phoenix Contact FL SWITCH 2005 >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2008 >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2016 >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2105 >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2108 >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2116 >= 0.0.0, < 3.50; Phoen…
Fixed in: Phoenix Contact FL SWITCH 2005 3.50, Phoenix Contact FL SWITCH 2008 3.50, Phoenix Contact FL SWITCH 2016 3.50, Phoenix Contact FL SWITCH 2105 3.50, Phoenix Contact FL SWITCH 2108 3.50, Phoenix Contact FL SWITCH 2116 3.50, Phoenix Contact FL SWITCH 2204-2TC-2SFX 3.50, Phoenix Contact FL SWITCH 2205 …

Steps:
1. Search this machine and project for Phoenix Contact FL SWITCH 2005, Phoenix Contact FL SWITCH 2008, Phoenix Contact FL SWITCH 2016, Phoenix Contact FL SWITCH 2105, Phoenix Contact FL SWITCH 2108, Phoenix Contact FL SWITCH 2116: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2025-41749 being exploited?

There is no confirmed exploitation: CVE-2025-41749 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.46% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2025-41749?

High: CVSS 7.1 (v3.1, scored by CNA). Remote, no login needed. A user has to take an action, such as opening a link, for the attack to work.

Which versions are affected by CVE-2025-41749?

Phoenix Contact FL SWITCH 2005 >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2008 >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2016 >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2105 >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2108 >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2116 >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2204-2TC-2SFX >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2205 >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2206-2FX >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2206-2FX SM >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2206-2FX SM ST >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2206-2FX ST >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2206-2SFX >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2206-2SFX PN >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2206C-2FX >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2207-FX >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2207-FX SM >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2208 >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2208 PN >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2208C >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2212-2TC-2SFX >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2214-2FX >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2214-2FX SM >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2214-2SFX >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2214-2SFX PN >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2216 >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2216 PN >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2304-2GC-2SFP >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2306-2SFP >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2306-2SFP PN >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2308 >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2308 PN >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2312-2GC-2SFP >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2314-2SFP >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2314-2SFP PN >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2316 >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2316 PN >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2404-2TC-2SFX >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2406-2SFX >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2406-2SFX PN >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2408 >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2408 PN >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2412-2TC-2SFX >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2414-2SFX >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2414-2SFX PN >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2416 >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2416 PN >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2504-2GC-2SFP >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2506-2SFP >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2506-2SFP PN >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2508 >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2508 PN >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2512-2GC-2SFP >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2514-2SFP >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2514-2SFP PN >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2516 >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2516 PN >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2608 >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2608 PN >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2708 >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2708 PN >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2303-8SP1 >= 0.0.0, < 3.50; Phoenix Contact FL NAT 2008 >= 0.0.0, < 3.50; Phoenix Contact FL NAT 2208 >= 0.0.0, < 3.50; Phoenix Contact FL NAT 2304-2GC-2SFP >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2008F >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2316/K1 >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2506-2SFP/K1 >= 0.0.0, < 3.50; Phoenix Contact FL SWITCH 2508/K1 >= 0.0.0, < 3.50.

Is there a fix for CVE-2025-41749?

Yes. Fixed in Phoenix Contact FL SWITCH 2005 3.50, Phoenix Contact FL SWITCH 2008 3.50, Phoenix Contact FL SWITCH 2016 3.50, Phoenix Contact FL SWITCH 2105 3.50, Phoenix Contact FL SWITCH 2108 3.50, Phoenix Contact FL SWITCH 2116 3.50, Phoenix Contact FL SWITCH 2204-2TC-2SFX 3.50, Phoenix Contact FL SWITCH 2205 3.50, Phoenix Contact FL SWITCH 2206-2FX 3.50, Phoenix Contact FL SWITCH 2206-2FX SM 3.50, Phoenix Contact FL SWITCH 2206-2FX SM ST 3.50, Phoenix Contact FL SWITCH 2206-2FX ST 3.50, Phoenix Contact FL SWITCH 2206-2SFX 3.50, Phoenix Contact FL SWITCH 2206-2SFX PN 3.50, Phoenix Contact FL SWITCH 2206C-2FX 3.50, Phoenix Contact FL SWITCH 2207-FX 3.50, Phoenix Contact FL SWITCH 2207-FX SM 3.50, Phoenix Contact FL SWITCH 2208 3.50, Phoenix Contact FL SWITCH 2208 PN 3.50, Phoenix Contact FL SWITCH 2208C 3.50, Phoenix Contact FL SWITCH 2212-2TC-2SFX 3.50, Phoenix Contact FL SWITCH 2214-2FX 3.50, Phoenix Contact FL SWITCH 2214-2FX SM 3.50, Phoenix Contact FL SWITCH 2214-2SFX 3.50, Phoenix Contact FL SWITCH 2214-2SFX PN 3.50, Phoenix Contact FL SWITCH 2216 3.50, Phoenix Contact FL SWITCH 2216 PN 3.50, Phoenix Contact FL SWITCH 2304-2GC-2SFP 3.50, Phoenix Contact FL SWITCH 2306-2SFP 3.50, Phoenix Contact FL SWITCH 2306-2SFP PN 3.50, Phoenix Contact FL SWITCH 2308 3.50, Phoenix Contact FL SWITCH 2308 PN 3.50, Phoenix Contact FL SWITCH 2312-2GC-2SFP 3.50, Phoenix Contact FL SWITCH 2314-2SFP 3.50, Phoenix Contact FL SWITCH 2314-2SFP PN 3.50, Phoenix Contact FL SWITCH 2316 3.50, Phoenix Contact FL SWITCH 2316 PN 3.50, Phoenix Contact FL SWITCH 2404-2TC-2SFX 3.50, Phoenix Contact FL SWITCH 2406-2SFX 3.50, Phoenix Contact FL SWITCH 2406-2SFX PN 3.50, Phoenix Contact FL SWITCH 2408 3.50, Phoenix Contact FL SWITCH 2408 PN 3.50, Phoenix Contact FL SWITCH 2412-2TC-2SFX 3.50, Phoenix Contact FL SWITCH 2414-2SFX 3.50, Phoenix Contact FL SWITCH 2414-2SFX PN 3.50, Phoenix Contact FL SWITCH 2416 3.50, Phoenix Contact FL SWITCH 2416 PN 3.50, Phoenix Contact FL SWITCH 2504-2GC-2SFP 3.50, Phoenix Contact FL SWITCH 2506-2SFP 3.50, Phoenix Contact FL SWITCH 2506-2SFP PN 3.50, Phoenix Contact FL SWITCH 2508 3.50, Phoenix Contact FL SWITCH 2508 PN 3.50, Phoenix Contact FL SWITCH 2512-2GC-2SFP 3.50, Phoenix Contact FL SWITCH 2514-2SFP 3.50, Phoenix Contact FL SWITCH 2514-2SFP PN 3.50, Phoenix Contact FL SWITCH 2516 3.50, Phoenix Contact FL SWITCH 2516 PN 3.50, Phoenix Contact FL SWITCH 2608 3.50, Phoenix Contact FL SWITCH 2608 PN 3.50, Phoenix Contact FL SWITCH 2708 3.50, Phoenix Contact FL SWITCH 2708 PN 3.50, Phoenix Contact FL SWITCH 2303-8SP1 3.50, Phoenix Contact FL NAT 2008 3.50, Phoenix Contact FL NAT 2208 3.50, Phoenix Contact FL NAT 2304-2GC-2SFP 3.50, Phoenix Contact FL SWITCH 2008F 3.50, Phoenix Contact FL SWITCH 2316/K1 3.50, Phoenix Contact FL SWITCH 2506-2SFP/K1 3.50, Phoenix Contact FL SWITCH 2508/K1 3.50. Upgrade FL SWITCH 2005 to 3.50 or later. Upgrade FL SWITCH 2008 to 3.50 or later. Upgrade FL SWITCH 2016 to 3.50 or later. Upgrade FL SWITCH 2105 to 3.50 or later. Upgrade FL SWITCH 2108 to 3.50 or later. Upgrade FL SWITCH 2116 to 3.50 or later. Upgrade FL SWITCH 2204-2TC-2SFX to 3.50 or later. Upgrade FL SWITCH 2205 to 3.50 or later.

How do I check if I'm affected by CVE-2025-41749?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors