CVE-2025-40892
Stored Cross-Site Scripting (XSS) in Reports in Guardian/CMC before 25.5.0
Mitigation
- Upgrade Guardian to 25.5.0 or later.
- Upgrade CMC to 25.5.0 or later.
- Vendor workaround: Use internal firewall features to limit access to the web management interface.
Who should check
- Anyone running Nozomi Networks Guardian < 25.5.0
- Anyone running Nozomi Networks CMC < 25.5.0
Vulnerability facts
- Affected
- Nozomi Networks Guardian < 25.5.0; Nozomi Networks CMC < 25.5.0
- Fixed in
- Nozomi Networks Guardian 25.5.0, Nozomi Networks CMC 25.5.0
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, login needed
- CVSS
- 7.1 (v4.0, CNA)CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:L/VI:H/VA:H/SC:L/SI:L/SA:LOpen in CVSS calculator
Show all 11 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Attack requirements: None
- Privileges required: Low
- User interaction: Passive
- Confidentiality impact: Low
- Integrity impact: High
- Availability impact: High
- Confidentiality impact on other systems: Low
- Integrity impact on other systems: Low
- Availability impact on other systems: Low
- EPSS
- 0.49% chance of exploitation in 30 days (percentile 35, 2026-11-26)
- CWE
- CWE-79
- Modified
Description
A Stored Cross-Site Scripting vulnerability was discovered in the Reports functionality due to improper validation of an input parameter. An authenticated user with report privileges can define a malicious report containing a JavaScript payload, or a victim can be socially engineered to import a malicious report template. When the victim views or imports the report, the XSS executes in their browser context, allowing the attacker to perform unauthorized actions as the victim, such as modify application data, disrupt application availability, and access limited sensitive information.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Nozomi Networks Guardian | < 25.5.0 | — | cvelist |
| Nozomi Networks CMC | < 25.5.0 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2025-40892. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2025-40892.md Affected: Nozomi Networks Guardian < 25.5.0; Nozomi Networks CMC < 25.5.0 Fixed in: Nozomi Networks Guardian 25.5.0, Nozomi Networks CMC 25.5.0 Steps: 1. Search this machine and project for Nozomi Networks Guardian, Nozomi Networks CMC: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
Vendor advisories
FAQ
Is CVE-2025-40892 being exploited?
There is no confirmed exploitation: CVE-2025-40892 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.49% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2025-40892?
High: CVSS 7.1 (v4.0, scored by CNA). Remote, login needed. A user has to take an action, such as opening a link, for the attack to work.
Which versions are affected by CVE-2025-40892?
Nozomi Networks Guardian < 25.5.0; Nozomi Networks CMC < 25.5.0.
Is there a fix for CVE-2025-40892?
Yes. Fixed in Nozomi Networks Guardian 25.5.0, Nozomi Networks CMC 25.5.0. Upgrade Guardian to 25.5.0 or later. Upgrade CMC to 25.5.0 or later. Vendor workaround: Use internal firewall features to limit access to the web management interface.
How do I check if I'm affected by CVE-2025-40892?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.