# CVE-2025-40800: A vulnerability has been identified in COMOS V10.6 (All versions \< V10.6.1), COMOS V10.6 (All versions \< V10.6.1), NX V…

> Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

- **Severity:** CRITICAL 9.1
- **CVSS:** 9.1 (v4.0, CNA) `CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N`
- **CVSS metrics:** Attack vector: Network; Attack complexity: Low; Attack requirements: Present; Privileges required: None; User interaction: None; Confidentiality impact: High; Integrity impact: High; Availability impact: None; Confidentiality impact on other systems: None; Integrity impact on other systems: None; Availability impact on other systems: None
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** None known
- **Remote exploitation:** Remote, no login needed
- **EPSS:** 0.29% (percentile 14, 2026-11-26)
- **CWE:** CWE-295
- **Published:** 2025-12-09T10:44:23.488Z
- **Modified:** 2026-10-07T11:10:00.153Z

## Who should check

- Anyone running Siemens COMOS V10.6 \< V10.6.1
- Anyone running Siemens NX V2412 \< V2412.8700
- Anyone running Siemens NX V2506 \< V2506.6000
- Anyone running Siemens Simcenter 3D \< V2506.6000
- Anyone running Siemens Simcenter Femap \< V2506.0002
- Anyone running Siemens Solid Edge SE2025 \< V225.0 Update 10
- Anyone running Siemens Solid Edge SE2026 \< V226.0 Update 1

## Description

A vulnerability has been identified in COMOS V10.6 (All versions \< V10.6.1), COMOS V10.6 (All versions \< V10.6.1), NX V2412 (All versions \< V2412.8700), NX V2506 (All versions \< V2506.6000), Simcenter 3D (All versions \< V2506.6000), Simcenter Femap (All versions \< V2506.0002), Solid Edge SE2025 (All versions \< V225.0 Update 10), Solid Edge SE2026 (All versions \< V226.0 Update 1). The IAM client in affected products is missing server certificate validation while establishing TLS connections to the authorization server. This could allow an attacker to perform a man-in-the-middle attack.

## Affected and fixed versions

- Siemens COMOS V10.6: \< V10.6.1 (cvelist)
- Siemens COMOS V10.6: \< V10.6.1 (cvelist)
- Siemens NX V2412: \< V2412.8700 (cvelist)
- Siemens NX V2506: \< V2506.6000 (cvelist)
- Siemens Simcenter 3D: \< V2506.6000 (cvelist)
- Siemens Simcenter Femap: \< V2506.0002 (cvelist)
- Siemens Solid Edge SE2025: \< V225.0 Update 10 (cvelist)
- Siemens Solid Edge SE2026: \< V226.0 Update 1 (cvelist)

## Mitigation

- No fix listed yet: follow the vendor advisory.

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2025-40800. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2025-40800.md
Affected: Siemens COMOS V10.6 < V10.6.1; Siemens COMOS V10.6 < V10.6.1; Siemens NX V2412 < V2412.8700; Siemens NX V2506 < V2506.6000; Siemens Simcenter 3D < V2506.6000; Siemens Simcenter Femap < V2506.0002; Siemens Solid Edge SE2025 < V225.0 Update 10; Siemens Solid Edge SE2026 < V226.0 Update 1
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Siemens COMOS V10.6, Siemens NX V2412, Siemens NX V2506, Siemens Simcenter 3D, Siemens Simcenter Femap, Siemens Solid Edge SE2025: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2025-40800 being exploited?

There is no confirmed exploitation: CVE-2025-40800 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.29% chance of exploitation in the next 30 days (as of 2026-11-26).

### How serious is CVE-2025-40800?

Critical: CVSS 9.1 (v4.0, scored by CNA). Remote, no login needed.

### Which versions are affected by CVE-2025-40800?

Siemens COMOS V10.6 \< V10.6.1; Siemens COMOS V10.6 \< V10.6.1; Siemens NX V2412 \< V2412.8700; Siemens NX V2506 \< V2506.6000; Siemens Simcenter 3D \< V2506.6000; Siemens Simcenter Femap \< V2506.0002; Siemens Solid Edge SE2025 \< V225.0 Update 10; Siemens Solid Edge SE2026 \< V226.0 Update 1.

### Is there a fix for CVE-2025-40800?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

### How do I check if I'm affected by CVE-2025-40800?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- other: <https://cert-portal.siemens.com/productcert/html/ssa-868571.html>
- other: <https://cert-portal.siemens.com/productcert/html/ssa-212953.html>

## Attribution

- CVE Program: CVE® is a registered trademark of The MITRE Corporation. CVE records © 1999–2026 The MITRE Corporation. <https://www.cve.org/Legal/TermsOfUse>
- NVD: This product uses data from the NVD API but is not endorsed or certified by the NVD. <https://nvd.nist.gov/vuln/detail/CVE-2025-40800>

HTML: <https://flawdb.com/CVE-2025-40800> · JSON: <https://flawdb.com/api/v1/entries/CVE-2025-40800>