# CVE-2025-40743: A vulnerability has been identified in SINUMERIK 828D PPU.4 (All versions \< V4.95 SP5), SINUMERIK 828D PPU.5 (All versi…

> Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

- **Severity:** HIGH 8.7
- **CVSS:** 8.7 (v4.0, CNA) `CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N`
- **CVSS metrics:** Attack vector: Adjacent network; Attack complexity: Low; Attack requirements: None; Privileges required: None; User interaction: None; Confidentiality impact: High; Integrity impact: High; Availability impact: Low; Confidentiality impact on other systems: None; Integrity impact on other systems: None; Availability impact on other systems: None
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** None known
- **Remote exploitation:** Not remotely exploitable (local or adjacent access needed)
- **EPSS:** 0.42% (percentile 28, 2026-11-26)
- **CWE:** CWE-288
- **Published:** 2025-08-12T11:17:03.997Z
- **Modified:** 2026-06-17T09:22:03.957Z

## Who should check

- Anyone running Siemens SINUMERIK 828D PPU.4 \< V4.95 SP5
- Anyone running Siemens SINUMERIK 828D PPU.5 \< V5.25 SP1
- Anyone running Siemens SINUMERIK 840D sl \< V4.95 SP5
- Anyone running Siemens SINUMERIK MC \< V1.25 SP1
- Anyone running Siemens SINUMERIK MC V1.15 \< V1.15 SP5
- Anyone running Siemens SINUMERIK ONE \< V6.25 SP1
- Anyone running Siemens SINUMERIK ONE V6.15 \< V6.15 SP5

## Description

A vulnerability has been identified in SINUMERIK 828D PPU.4 (All versions \< V4.95 SP5), SINUMERIK 828D PPU.5 (All versions \< V5.25 SP1), SINUMERIK 840D sl (All versions \< V4.95 SP5), SINUMERIK MC (All versions \< V1.25 SP1), SINUMERIK MC V1.15 (All versions \< V1.15 SP5), SINUMERIK ONE (All versions \< V6.25 SP1), SINUMERIK ONE V6.15 (All versions \< V6.15 SP5). The affected application improperly validates authentication for its VNC access service, allowing access with insufficient password verification.
This could allow an attacker to gain unauthorized remote access and potentially compromise system confidentiality, integrity, or availability.

## Affected and fixed versions

- Siemens SINUMERIK 828D PPU.4: \< V4.95 SP5 (cvelist)
- Siemens SINUMERIK 828D PPU.5: \< V5.25 SP1 (cvelist)
- Siemens SINUMERIK 840D sl: \< V4.95 SP5 (cvelist)
- Siemens SINUMERIK MC: \< V1.25 SP1 (cvelist)
- Siemens SINUMERIK MC V1.15: \< V1.15 SP5 (cvelist)
- Siemens SINUMERIK ONE: \< V6.25 SP1 (cvelist)
- Siemens SINUMERIK ONE V6.15: \< V6.15 SP5 (cvelist)

## Mitigation

- No fix listed yet: follow the vendor advisory.

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2025-40743. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2025-40743.md
Affected: Siemens SINUMERIK 828D PPU.4 < V4.95 SP5; Siemens SINUMERIK 828D PPU.5 < V5.25 SP1; Siemens SINUMERIK 840D sl < V4.95 SP5; Siemens SINUMERIK MC < V1.25 SP1; Siemens SINUMERIK MC V1.15 < V1.15 SP5; Siemens SINUMERIK ONE < V6.25 SP1; Siemens SINUMERIK ONE V6.15 < V6.15 SP5
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Siemens SINUMERIK 828D PPU.4, Siemens SINUMERIK 828D PPU.5, Siemens SINUMERIK 840D sl, Siemens SINUMERIK MC, Siemens SINUMERIK MC V1.15, Siemens SINUMERIK ONE: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2025-40743 being exploited?

There is no confirmed exploitation: CVE-2025-40743 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.42% chance of exploitation in the next 30 days (as of 2026-11-26).

### How serious is CVE-2025-40743?

High: CVSS 8.7 (v4.0, scored by CNA). Not remotely exploitable (local or adjacent access needed).

### Which versions are affected by CVE-2025-40743?

Siemens SINUMERIK 828D PPU.4 \< V4.95 SP5; Siemens SINUMERIK 828D PPU.5 \< V5.25 SP1; Siemens SINUMERIK 840D sl \< V4.95 SP5; Siemens SINUMERIK MC \< V1.25 SP1; Siemens SINUMERIK MC V1.15 \< V1.15 SP5; Siemens SINUMERIK ONE \< V6.25 SP1; Siemens SINUMERIK ONE V6.15 \< V6.15 SP5.

### Is there a fix for CVE-2025-40743?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

### How do I check if I'm affected by CVE-2025-40743?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- other: <https://cert-portal.siemens.com/productcert/html/ssa-177847.html>

## Attribution

- CVE Program: CVE® is a registered trademark of The MITRE Corporation. CVE records © 1999–2026 The MITRE Corporation. <https://www.cve.org/Legal/TermsOfUse>
- NVD: This product uses data from the NVD API but is not endorsed or certified by the NVD. <https://nvd.nist.gov/vuln/detail/CVE-2025-40743>

HTML: <https://flawdb.com/CVE-2025-40743> · JSON: <https://flawdb.com/api/v1/entries/CVE-2025-40743>