# CVE-2025-40584: A vulnerability has been identified in SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions),…

> Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

- **Severity:** MEDIUM 6.8
- **CVSS:** 6.8 (v4.0, CNA) `CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N`
- **CVSS metrics:** Attack vector: Local; Attack complexity: Low; Attack requirements: None; Privileges required: None; User interaction: Passive; Confidentiality impact: High; Integrity impact: None; Availability impact: None; Confidentiality impact on other systems: None; Integrity impact on other systems: None; Availability impact on other systems: None
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** None known
- **Remote exploitation:** Not remotely exploitable (local or adjacent access needed)
- **EPSS:** 0.29% (percentile 14, 2026-11-26)
- **CWE:** CWE-611
- **Published:** 2025-08-12T11:17:02.605Z
- **Modified:** 2026-06-17T09:21:47.453Z

## Who should check

- Anyone running Siemens SIMOTION SCOUT TIA V5.4 \< \*
- Anyone running Siemens SIMOTION SCOUT TIA V5.5 \< \*
- Anyone running Siemens SIMOTION SCOUT TIA V5.6 \< V5.6 SP1 HF7
- Anyone running Siemens SIMOTION SCOUT TIA V5.7 \< V5.7 SP1 HF1
- Anyone running Siemens SIMOTION SCOUT V5.4 \< \*
- Anyone running Siemens SIMOTION SCOUT V5.5 \< \*
- Anyone running Siemens SIMOTION SCOUT V5.6 \< V5.6 SP1 HF7
- Anyone running Siemens SIMOTION SCOUT V5.7 \< V5.7 SP1 HF1

## Description

A vulnerability has been identified in SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions \< V5.6 SP1 HF7), SIMOTION SCOUT TIA V5.7 (All versions \< V5.7 SP1 HF1), SIMOTION SCOUT V5.4 (All versions), SIMOTION SCOUT V5.5 (All versions), SIMOTION SCOUT V5.6 (All versions \< V5.6 SP1 HF7), SIMOTION SCOUT V5.7 (All versions \< V5.7 SP1 HF1), SINAMICS STARTER V5.5 (All versions), SINAMICS STARTER V5.6 (All versions), SINAMICS STARTER V5.7 (All versions \< V5.7 HF2). The affected application contains a XML External Entity Injection (XXE) vulnerability while parsing specially crafted XML files. This could allow an attacker to read arbitrary files in the system.

## Affected and fixed versions

- Siemens SIMOTION SCOUT TIA V5.4: \< \* (cvelist)
- Siemens SIMOTION SCOUT TIA V5.5: \< \* (cvelist)
- Siemens SIMOTION SCOUT TIA V5.6: \< V5.6 SP1 HF7 (cvelist)
- Siemens SIMOTION SCOUT TIA V5.7: \< V5.7 SP1 HF1 (cvelist)
- Siemens SIMOTION SCOUT V5.4: \< \* (cvelist)
- Siemens SIMOTION SCOUT V5.5: \< \* (cvelist)
- Siemens SIMOTION SCOUT V5.6: \< V5.6 SP1 HF7 (cvelist)
- Siemens SIMOTION SCOUT V5.7: \< V5.7 SP1 HF1 (cvelist)
- Siemens SINAMICS STARTER V5.5: \< \* (cvelist)
- Siemens SINAMICS STARTER V5.6: \< \* (cvelist)
- Siemens SINAMICS STARTER V5.7: \< V5.7 HF2 (cvelist)

## Mitigation

- No fix listed yet: follow the vendor advisory.

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2025-40584. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2025-40584.md
Affected: Siemens SIMOTION SCOUT TIA V5.4 < *; Siemens SIMOTION SCOUT TIA V5.5 < *; Siemens SIMOTION SCOUT TIA V5.6 < V5.6 SP1 HF7; Siemens SIMOTION SCOUT TIA V5.7 < V5.7 SP1 HF1; Siemens SIMOTION SCOUT V5.4 < *; Siemens SIMOTION SCOUT V5.5 < *; Siemens SIMOTION SCOUT V5.6 < V5.6 SP1 HF7; Siemens SIMOTION SC…
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Siemens SIMOTION SCOUT TIA V5.4, Siemens SIMOTION SCOUT TIA V5.5, Siemens SIMOTION SCOUT TIA V5.6, Siemens SIMOTION SCOUT TIA V5.7, Siemens SIMOTION SCOUT V5.4, Siemens SIMOTION SCOUT V5.5: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2025-40584 being exploited?

There is no confirmed exploitation: CVE-2025-40584 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.29% chance of exploitation in the next 30 days (as of 2026-11-26).

### How serious is CVE-2025-40584?

Medium: CVSS 6.8 (v4.0, scored by CNA). Not remotely exploitable (local or adjacent access needed). A user has to take an action, such as opening a link, for the attack to work.

### Which versions are affected by CVE-2025-40584?

Siemens SIMOTION SCOUT TIA V5.4 \< \*; Siemens SIMOTION SCOUT TIA V5.5 \< \*; Siemens SIMOTION SCOUT TIA V5.6 \< V5.6 SP1 HF7; Siemens SIMOTION SCOUT TIA V5.7 \< V5.7 SP1 HF1; Siemens SIMOTION SCOUT V5.4 \< \*; Siemens SIMOTION SCOUT V5.5 \< \*; Siemens SIMOTION SCOUT V5.6 \< V5.6 SP1 HF7; Siemens SIMOTION SCOUT V5.7 \< V5.7 SP1 HF1; Siemens SINAMICS STARTER V5.5 \< \*; Siemens SINAMICS STARTER V5.6 \< \*; Siemens SINAMICS STARTER V5.7 \< V5.7 HF2.

### Is there a fix for CVE-2025-40584?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

### How do I check if I'm affected by CVE-2025-40584?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- other: <https://cert-portal.siemens.com/productcert/html/ssa-186293.html>

## Attribution

- CVE Program: CVE® is a registered trademark of The MITRE Corporation. CVE records © 1999–2026 The MITRE Corporation. <https://www.cve.org/Legal/TermsOfUse>
- NVD: This product uses data from the NVD API but is not endorsed or certified by the NVD. <https://nvd.nist.gov/vuln/detail/CVE-2025-40584>

HTML: <https://flawdb.com/CVE-2025-40584> · JSON: <https://flawdb.com/api/v1/entries/CVE-2025-40584>