# CVE-2025-40570: A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions \< V10.0), SIPROTEC 5 6MD85 (CP300) (All v…

> Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

- **Severity:** LOW 2.4
- **CVSS:** 2.4 (v4.0, CNA) `CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N`
- **CVSS metrics:** Attack vector: Physical; Attack complexity: Low; Attack requirements: None; Privileges required: None; User interaction: None; Confidentiality impact: None; Integrity impact: None; Availability impact: Low; Confidentiality impact on other systems: None; Integrity impact on other systems: None; Availability impact on other systems: None
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** None known
- **Remote exploitation:** Not remotely exploitable (local or adjacent access needed)
- **EPSS:** 0.34% (percentile 20, 2026-11-26)
- **CWE:** CWE-770
- **Published:** 2025-08-12T11:17:01.195Z
- **Modified:** 2026-06-17T09:21:45.657Z

## Who should check

- Anyone running Siemens SIPROTEC 5 6MD84 (CP300) \< V10.0
- Anyone running Siemens SIPROTEC 5 6MD85 (CP300) \>= V7.80, \< V10.0
- Anyone running Siemens SIPROTEC 5 6MD86 (CP300) \>= V7.80, \< V10.0
- Anyone running Siemens SIPROTEC 5 6MD89 (CP300) \>= V7.80, \< V10.0
- Anyone running Siemens SIPROTEC 5 6MU85 (CP300) \>= V7.80, \< V10.0
- Anyone running Siemens SIPROTEC 5 7KE85 (CP300) \>= V7.80, \< V10.0
- Anyone running Siemens SIPROTEC 5 7SA82 (CP150) \< V10.0
- Anyone running Siemens SIPROTEC 5 7SA86 (CP300) \>= V7.80, \< V10.0

## Description

A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions \< V10.0), SIPROTEC 5 6MD85 (CP300) (All versions \>= V7.80 \< V10.0), SIPROTEC 5 6MD86 (CP300) (All versions \>= V7.80 \< V10.0), SIPROTEC 5 6MD89 (CP300) (All versions \>= V7.80 \< V10.0), SIPROTEC 5 6MU85 (CP300) (All versions \>= V7.80 \< V10.0), SIPROTEC 5 7KE85 (CP300) (All versions \>= V7.80 \< V10.0), SIPROTEC 5 7SA82 (CP150) (All versions \< V10.0), SIPROTEC 5 7SA86 (CP300) (All versions \>= V7.80 \< V10.0), SIPROTEC 5 7SA87 (CP300) (All versions \>= V7.80 \< V10.0), SIPROTEC 5 7SD82 (CP150) (All versions \< V10.0), SIPROTEC 5 7SD86 (CP300) (All versions \>= V7.80 \< V10.0), SIPROTEC 5 7SD87 (CP300) (All versions \>= V7.80 \< V10.0), SIPROTEC 5 7SJ81 (CP150) (All versions \< V10.0), SIPROTEC 5 7SJ82 (CP150) (All versions \< V10.0), SIPROTEC 5 7SJ85 (CP300) (All versions \>= V7.80 \< V10.0), SIPROTEC 5 7SJ86 (CP300) (All versions \>= V7.80 \< V10.0), SIPROTEC 5 7SK82 (CP150) (All versions \< V10.0), SIPROTEC 5 7SK85 (CP300) (All versions \>= V7.80 \< V10.0), SIPROTEC 5 7SL82 (CP150) (All versions \< V10.0), SIPROTEC 5 7SL86 (CP300) (All versions \>= V7.80 \< V10.0), SIPROTEC 5 7SL87 (CP300) (All versions \>= V7.80 \< V10.0), SIPROTEC 5 7SS85 (CP300) (All versions \>= V7.80 \< V10.0), SIPROTEC 5 7ST85 (CP300) (All versions \< V10.0), SIPROTEC 5 7ST86 (CP300) (All versions \< V10.0), SIPROTEC 5 7SX82 (CP150) (All versions \< V10.0), SIPROTEC 5 7SX85 (CP300) (All versions \< V10.0), SIPROTEC 5 7SY82 (CP150) (All versions \< V10.0), SIPROTEC 5 7UM85 (CP300) (All versions \>= V7.80 \< V10.0), SIPROTEC 5 7UT82 (CP150) (All versions \< V10.0), SIPROTEC 5 7UT85 (CP300) (All versions \>= V7.80 \< V10.0), SIPROTEC 5 7UT86 (CP300) (All versions \>= V7.80 \< V10.0), SIPROTEC 5 7UT87 (CP300) (All versions \>= V7.80 \< V10.0), SIPROTEC 5 7VE85 (CP300) (All versions \>= V7.80 \< V10.0), SIPROTEC 5 7VK87 (CP300) (All versions \>= V7.80 \< V10.0), SIPROTEC 5 7VU85 (CP300) (All versions \< V10.0), SIPROTEC 5 Compact 7SX800 (CP050) (All versions \< V10.0). Affected devices do not properly limit the bandwidth for incoming network packets over their local USB port. This could allow an attacker with physical access to send specially crafted packets with high bandwidth to the affected devices thus forcing them to exhaust their memory and stop responding to any network traffic via the local USB port. Affected devices reset themselves automatically after a successful attack. The protection function is not affected of this vulnerability.

## Affected and fixed versions

- Siemens SIPROTEC 5 6MD84 (CP300): \< V10.0 (cvelist)
- Siemens SIPROTEC 5 6MD85 (CP300): \>= V7.80, \< V10.0 (cvelist)
- Siemens SIPROTEC 5 6MD86 (CP300): \>= V7.80, \< V10.0 (cvelist)
- Siemens SIPROTEC 5 6MD89 (CP300): \>= V7.80, \< V10.0 (cvelist)
- Siemens SIPROTEC 5 6MU85 (CP300): \>= V7.80, \< V10.0 (cvelist)
- Siemens SIPROTEC 5 7KE85 (CP300): \>= V7.80, \< V10.0 (cvelist)
- Siemens SIPROTEC 5 7SA82 (CP150): \< V10.0 (cvelist)
- Siemens SIPROTEC 5 7SA86 (CP300): \>= V7.80, \< V10.0 (cvelist)
- Siemens SIPROTEC 5 7SA87 (CP300): \>= V7.80, \< V10.0 (cvelist)
- Siemens SIPROTEC 5 7SD82 (CP150): \< V10.0 (cvelist)
- Siemens SIPROTEC 5 7SD86 (CP300): \>= V7.80, \< V10.0 (cvelist)
- Siemens SIPROTEC 5 7SD87 (CP300): \>= V7.80, \< V10.0 (cvelist)
- Siemens SIPROTEC 5 7SJ81 (CP150): \< V10.0 (cvelist)
- Siemens SIPROTEC 5 7SJ82 (CP150): \< V10.0 (cvelist)
- Siemens SIPROTEC 5 7SJ85 (CP300): \>= V7.80, \< V10.0 (cvelist)
- Siemens SIPROTEC 5 7SJ86 (CP300): \>= V7.80, \< V10.0 (cvelist)
- Siemens SIPROTEC 5 7SK82 (CP150): \< V10.0 (cvelist)
- Siemens SIPROTEC 5 7SK85 (CP300): \>= V7.80, \< V10.0 (cvelist)
- Siemens SIPROTEC 5 7SL82 (CP150): \< V10.0 (cvelist)
- Siemens SIPROTEC 5 7SL86 (CP300): \>= V7.80, \< V10.0 (cvelist)
- Siemens SIPROTEC 5 7SL87 (CP300): \>= V7.80, \< V10.0 (cvelist)
- Siemens SIPROTEC 5 7SS85 (CP300): \>= V7.80, \< V10.0 (cvelist)
- Siemens SIPROTEC 5 7ST85 (CP300): \< V10.0 (cvelist)
- Siemens SIPROTEC 5 7ST86 (CP300): \< V10.0 (cvelist)
- Siemens SIPROTEC 5 7SX82 (CP150): \< V10.0 (cvelist)
- Siemens SIPROTEC 5 7SX85 (CP300): \< V10.0 (cvelist)
- Siemens SIPROTEC 5 7SY82 (CP150): \< V10.0 (cvelist)
- Siemens SIPROTEC 5 7UM85 (CP300): \>= V7.80, \< V10.0 (cvelist)
- Siemens SIPROTEC 5 7UT82 (CP150): \< V10.0 (cvelist)
- Siemens SIPROTEC 5 7UT85 (CP300): \>= V7.80, \< V10.0 (cvelist)
- Siemens SIPROTEC 5 7UT86 (CP300): \>= V7.80, \< V10.0 (cvelist)
- Siemens SIPROTEC 5 7UT87 (CP300): \>= V7.80, \< V10.0 (cvelist)
- Siemens SIPROTEC 5 7VE85 (CP300): \>= V7.80, \< V10.0 (cvelist)
- Siemens SIPROTEC 5 7VK87 (CP300): \>= V7.80, \< V10.0 (cvelist)
- Siemens SIPROTEC 5 7VU85 (CP300): \< V10.0 (cvelist)
- Siemens SIPROTEC 5 Compact 7SX800 (CP050): \< V10.0 (cvelist)

## Mitigation

- No fix listed yet: follow the vendor advisory.

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2025-40570. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2025-40570.md
Affected: Siemens SIPROTEC 5 6MD84 (CP300) < V10.0; Siemens SIPROTEC 5 6MD85 (CP300) >= V7.80, < V10.0; Siemens SIPROTEC 5 6MD86 (CP300) >= V7.80, < V10.0; Siemens SIPROTEC 5 6MD89 (CP300) >= V7.80, < V10.0; Siemens SIPROTEC 5 6MU85 (CP300) >= V7.80, < V10.0; Siemens SIPROTEC 5 7KE85 (CP300) >= V7.80, < V10.…
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Siemens SIPROTEC 5 6MD84 (CP300), Siemens SIPROTEC 5 6MD85 (CP300), Siemens SIPROTEC 5 6MD86 (CP300), Siemens SIPROTEC 5 6MD89 (CP300), Siemens SIPROTEC 5 6MU85 (CP300), Siemens SIPROTEC 5 7KE85 (CP300): dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2025-40570 being exploited?

There is no confirmed exploitation: CVE-2025-40570 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.34% chance of exploitation in the next 30 days (as of 2026-11-26).

### How serious is CVE-2025-40570?

Low: CVSS 2.4 (v4.0, scored by CNA). Not remotely exploitable (local or adjacent access needed).

### Which versions are affected by CVE-2025-40570?

Siemens SIPROTEC 5 6MD84 (CP300) \< V10.0; Siemens SIPROTEC 5 6MD85 (CP300) \>= V7.80, \< V10.0; Siemens SIPROTEC 5 6MD86 (CP300) \>= V7.80, \< V10.0; Siemens SIPROTEC 5 6MD89 (CP300) \>= V7.80, \< V10.0; Siemens SIPROTEC 5 6MU85 (CP300) \>= V7.80, \< V10.0; Siemens SIPROTEC 5 7KE85 (CP300) \>= V7.80, \< V10.0; Siemens SIPROTEC 5 7SA82 (CP150) \< V10.0; Siemens SIPROTEC 5 7SA86 (CP300) \>= V7.80, \< V10.0; Siemens SIPROTEC 5 7SA87 (CP300) \>= V7.80, \< V10.0; Siemens SIPROTEC 5 7SD82 (CP150) \< V10.0; Siemens SIPROTEC 5 7SD86 (CP300) \>= V7.80, \< V10.0; Siemens SIPROTEC 5 7SD87 (CP300) \>= V7.80, \< V10.0; Siemens SIPROTEC 5 7SJ81 (CP150) \< V10.0; Siemens SIPROTEC 5 7SJ82 (CP150) \< V10.0; Siemens SIPROTEC 5 7SJ85 (CP300) \>= V7.80, \< V10.0; Siemens SIPROTEC 5 7SJ86 (CP300) \>= V7.80, \< V10.0; Siemens SIPROTEC 5 7SK82 (CP150) \< V10.0; Siemens SIPROTEC 5 7SK85 (CP300) \>= V7.80, \< V10.0; Siemens SIPROTEC 5 7SL82 (CP150) \< V10.0; Siemens SIPROTEC 5 7SL86 (CP300) \>= V7.80, \< V10.0; Siemens SIPROTEC 5 7SL87 (CP300) \>= V7.80, \< V10.0; Siemens SIPROTEC 5 7SS85 (CP300) \>= V7.80, \< V10.0; Siemens SIPROTEC 5 7ST85 (CP300) \< V10.0; Siemens SIPROTEC 5 7ST86 (CP300) \< V10.0; Siemens SIPROTEC 5 7SX82 (CP150) \< V10.0; Siemens SIPROTEC 5 7SX85 (CP300) \< V10.0; Siemens SIPROTEC 5 7SY82 (CP150) \< V10.0; Siemens SIPROTEC 5 7UM85 (CP300) \>= V7.80, \< V10.0; Siemens SIPROTEC 5 7UT82 (CP150) \< V10.0; Siemens SIPROTEC 5 7UT85 (CP300) \>= V7.80, \< V10.0; Siemens SIPROTEC 5 7UT86 (CP300) \>= V7.80, \< V10.0; Siemens SIPROTEC 5 7UT87 (CP300) \>= V7.80, \< V10.0; Siemens SIPROTEC 5 7VE85 (CP300) \>= V7.80, \< V10.0; Siemens SIPROTEC 5 7VK87 (CP300) \>= V7.80, \< V10.0; Siemens SIPROTEC 5 7VU85 (CP300) \< V10.0; Siemens SIPROTEC 5 Compact 7SX800 (CP050) \< V10.0.

### Is there a fix for CVE-2025-40570?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

### How do I check if I'm affected by CVE-2025-40570?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- other: <https://cert-portal.siemens.com/productcert/html/ssa-894058.html>

## Attribution

- CVE Program: CVE® is a registered trademark of The MITRE Corporation. CVE records © 1999–2026 The MITRE Corporation. <https://www.cve.org/Legal/TermsOfUse>
- NVD: This product uses data from the NVD API but is not endorsed or certified by the NVD. <https://nvd.nist.gov/vuln/detail/CVE-2025-40570>

HTML: <https://flawdb.com/CVE-2025-40570> · JSON: <https://flawdb.com/api/v1/entries/CVE-2025-40570>