CVE-2025-40569
A vulnerability has been identified in RUGGEDCOM RST2428P (6GK6242-6PA00) (All versions < V3.2), SCALANCE XCH328 (6GK53…
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Siemens RUGGEDCOM RST2428P < V3.2
- Anyone running Siemens SCALANCE XCH328 < V3.2
- Anyone running Siemens SCALANCE XCM324 < V3.2
- Anyone running Siemens SCALANCE XCM328 < V3.2
- Anyone running Siemens SCALANCE XCM332 < V3.2
- Anyone running Siemens SCALANCE XRH334 (24 V DC, 8xFO, CC) < V3.2
- Anyone running Siemens SCALANCE XRM334 (230 V AC, 12xFO) < V3.2
- Anyone running Siemens SCALANCE XRM334 (230 V AC, 8xFO) < V3.2
Vulnerability facts
- Affected
- Siemens RUGGEDCOM RST2428P < V3.2; Siemens SCALANCE XCH328 < V3.2; Siemens SCALANCE XCM324 < V3.2; Siemens SCALANCE XCM328 < V3.2; Siemens SCALANCE XCM332 < V3.2; Siemens SCALANCE XRH334 (24 V DC, 8xFO, CC) < V3.2; Siemens SCALANCE XRM334 (230 V AC, 12xFO) < V3.2; Siemens SCALANCE XRM334 (230 V AC, 8xFO) < V3.2; Siemens SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) < V3.2; Siemens SCALANCE XRM334 (24 V DC, 12xFO) < V3.2; Siemens SCALANCE XRM334 (24 V DC, 8xFO) < V3.2; Siemens SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) < V3.2; Siemens SCALANCE XRM334 (2x230 V AC, 12xFO) < V3.2; Siemens SCALANCE XRM334 (2x230 V AC, 8xFO) < V3.2; Siemens SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) < V3.2
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, login needed
- CVSS
- 5.9 (v4.0, CNA)CVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:P/VC:N/VI:H/VA:N/SC:N/SI:N/SA:NOpen in CVSS calculator
Show all 11 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Attack requirements: Present
- Privileges required: Low
- User interaction: Passive
- Confidentiality impact: None
- Integrity impact: High
- Availability impact: None
- Confidentiality impact on other systems: None
- Integrity impact on other systems: None
- Availability impact on other systems: None
- EPSS
- 0.42% chance of exploitation in 30 days (percentile 28, 2026-11-26)
- CWE
- CWE-362
- Modified
Description
A vulnerability has been identified in RUGGEDCOM RST2428P (6GK6242-6PA00) (All versions < V3.2), SCALANCE XCH328 (6GK5328-4TS01-2EC2) (All versions < V3.2), SCALANCE XCM324 (6GK5324-8TS01-2AC2) (All versions < V3.2), SCALANCE XCM328 (6GK5328-4TS01-2AC2) (All versions < V3.2), SCALANCE XCM332 (6GK5332-0GA01-2AC2) (All versions < V3.2), SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3) (All versions < V3.2), SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3) (All versions < V3.2), SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3) (All versions < V3.2), SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-4AR3) (All versions < V3.2). The "Load Configuration from Local PC" functionality in the web interface of affected products contains a race condition vulnerability. This could allow an authenticated remote attacker to make the affected product load an attacker controlled configuration instead of the legitimate one. Successful exploitation requires that a legitimate administrator invokes the functionality and the attacker wins the race condition.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Siemens RUGGEDCOM RST2428P | < V3.2 | — | cvelist |
| Siemens SCALANCE XCH328 | < V3.2 | — | cvelist |
| Siemens SCALANCE XCM324 | < V3.2 | — | cvelist |
| Siemens SCALANCE XCM328 | < V3.2 | — | cvelist |
| Siemens SCALANCE XCM332 | < V3.2 | — | cvelist |
| Siemens SCALANCE XRH334 (24 V DC, 8xFO, CC) | < V3.2 | — | cvelist |
| Siemens SCALANCE XRM334 (230 V AC, 12xFO) | < V3.2 | — | cvelist |
| Siemens SCALANCE XRM334 (230 V AC, 8xFO) | < V3.2 | — | cvelist |
| Siemens SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) | < V3.2 | — | cvelist |
| Siemens SCALANCE XRM334 (24 V DC, 12xFO) | < V3.2 | — | cvelist |
| Siemens SCALANCE XRM334 (24 V DC, 8xFO) | < V3.2 | — | cvelist |
| Siemens SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) | < V3.2 | — | cvelist |
| Siemens SCALANCE XRM334 (2x230 V AC, 12xFO) | < V3.2 | — | cvelist |
| Siemens SCALANCE XRM334 (2x230 V AC, 8xFO) | < V3.2 | — | cvelist |
| Siemens SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) | < V3.2 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2025-40569. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2025-40569.md Affected: Siemens RUGGEDCOM RST2428P < V3.2; Siemens SCALANCE XCH328 < V3.2; Siemens SCALANCE XCM324 < V3.2; Siemens SCALANCE XCM328 < V3.2; Siemens SCALANCE XCM332 < V3.2; Siemens SCALANCE XRH334 (24 V DC, 8xFO, CC) < V3.2; Siemens SCALANCE XRM334 (230 V AC, 12xFO) < V3.2; Siemens SCALANCE XRM334 (230 V AC,… Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Siemens RUGGEDCOM RST2428P, Siemens SCALANCE XCH328, Siemens SCALANCE XCM324, Siemens SCALANCE XCM328, Siemens SCALANCE XCM332, Siemens SCALANCE XRH334 (24 V DC, 8xFO, CC): dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2025-40569 being exploited?
There is no confirmed exploitation: CVE-2025-40569 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.42% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2025-40569?
Medium: CVSS 5.9 (v4.0, scored by CNA). Remote, login needed. A user has to take an action, such as opening a link, for the attack to work.
Which versions are affected by CVE-2025-40569?
Siemens RUGGEDCOM RST2428P < V3.2; Siemens SCALANCE XCH328 < V3.2; Siemens SCALANCE XCM324 < V3.2; Siemens SCALANCE XCM328 < V3.2; Siemens SCALANCE XCM332 < V3.2; Siemens SCALANCE XRH334 (24 V DC, 8xFO, CC) < V3.2; Siemens SCALANCE XRM334 (230 V AC, 12xFO) < V3.2; Siemens SCALANCE XRM334 (230 V AC, 8xFO) < V3.2; Siemens SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) < V3.2; Siemens SCALANCE XRM334 (24 V DC, 12xFO) < V3.2; Siemens SCALANCE XRM334 (24 V DC, 8xFO) < V3.2; Siemens SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) < V3.2; Siemens SCALANCE XRM334 (2x230 V AC, 12xFO) < V3.2; Siemens SCALANCE XRM334 (2x230 V AC, 8xFO) < V3.2; Siemens SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) < V3.2.
Is there a fix for CVE-2025-40569?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2025-40569?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.