# CVE-2025-36535: AutomationDirect MB-Gateway Missing Authentication for Critical Function

> Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

- **Severity:** CRITICAL 10.0
- **CVSS:** 10.0 (v4.0, CNA) `CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H`
- **CVSS metrics:** Attack vector: Network; Attack complexity: Low; Attack requirements: None; Privileges required: None; User interaction: None; Confidentiality impact: High; Integrity impact: High; Availability impact: High; Confidentiality impact on other systems: High; Integrity impact on other systems: High; Availability impact on other systems: High
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** None known
- **Remote exploitation:** Remote, no login needed
- **EPSS:** 1.41% (percentile 73, 2026-11-26)
- **CWE:** CWE-306
- **Published:** 2025-05-21T19:52:13.068Z
- **Modified:** 2026-06-17T09:14:46.617Z

## Who should check

- Anyone running AutomationDirect MB-Gateway All

## Description

The embedded web server lacks authentication and access controls, allowing unrestricted remote access. This could lead to configuration changes, operational disruption, or arbitrary code execution depending on the environment and exposed functionality.

## Affected and fixed versions

- AutomationDirect MB-Gateway: All (cvelist)

## Mitigation

- Vendor workaround: The hardware limitation of MB-Gateway does not provide for the implementation of proper access control update. AutomationDirect recommends that users plan for replacement of MB-Gateway with  EKI-1221-CE https://www.automationdirect.com/adc/shopping/catalog/communications/protocol\_gateways/modbus\_gateways/eki-1221-ce .
- 
- If an immediate replacement is not feasible, AutomationDirect recommends considering the following interim steps until the programming software can be updated:
- 
-   \*  Restrict network exposure: Ensure devices affected are not accessible from the Internet or untrusted networks. Place them behind firewalls.
-   \*  Use dedicated, secure internal networks or air-gapped systems for communication with programmable devices.
-   \*  Control Access: Restrict physical and logical access to authorized personnel only.
-   \*  Implement Whitelisting: Use application whitelisting to allow only pre-approved and trusted access. Block untrusted or unauthorized applications.
-   \*  Monitor and Log Activity: Enable logging and monitoring of system activities to detect potential anomalies or unauthorized actions. Regularly review logs for suspicious activity.
-   \*  Use Secure Backup and Recovery: Regularly back up the workstation and its configurations to a secure location. Test recovery procedures to ensure minimal downtime in the event of an incident.
-   \*  Plan for device replacement: Organizations should begin evaluating and migrating to supported hardware with active vendor support.

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2025-36535. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2025-36535.md
Affected: AutomationDirect MB-Gateway All
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for AutomationDirect MB-Gateway: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2025-36535 being exploited?

There is no confirmed exploitation: CVE-2025-36535 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 1.41% chance of exploitation in the next 30 days (as of 2026-11-26).

### How serious is CVE-2025-36535?

Critical: CVSS 10.0 (v4.0, scored by CNA). Remote, no login needed.

### Which versions are affected by CVE-2025-36535?

AutomationDirect MB-Gateway All.

### Is there a fix for CVE-2025-36535?

No fixed version is listed in the sources yet. Vendor workaround: The hardware limitation of MB-Gateway does not provide for the implementation of proper access control update. AutomationDirect recommends that users plan for replacement of MB-Gateway with  EKI-1221-CE https://www.automationdirect.com/adc/shopping/catalog/communications/protocol\_gateways/modbus\_gateways/eki-1221-ce .  If an immediate replacement is not feasible, AutomationDirect recommends considering the following interim steps until the programming software can be updated:    \*  Restrict network exposure: Ensure devices affected are not accessible from the Internet or untrusted networks. Place them behind firewalls.   \*  Use dedicated, secure internal networks or air-gapped systems for communication with programmable devices.   \*  Control Access: Restrict physical and logical access to authorized personnel only.   \*  Implement Whitelisting: Use application whitelisting to allow only pre-approved and trusted access. Block untrusted or unauthorized applications.   \*  Monitor and Log Activity: Enable logging and monitoring of system activities to detect potential anomalies or unauthorized actions. Regularly review logs for suspicious activity.   \*  Use Secure Backup and Recovery: Regularly back up the workstation and its configurations to a secure location. Test recovery procedures to ensure minimal downtime in the event of an incident.   \*  Plan for device replacement: Organizations should begin evaluating and migrating to supported hardware with active vendor support.

### How do I check if I'm affected by CVE-2025-36535?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- other: <https://www.cisa.gov/news-events/ics-advisories/icsa-25-140-09>
- other: <https://www.automationdirect.com/adc/shopping/catalog/communications/protocol_gateways/modbus_gateways/eki-1221-ce>

## Attribution

- CVE Program: CVE® is a registered trademark of The MITRE Corporation. CVE records © 1999–2026 The MITRE Corporation. <https://www.cve.org/Legal/TermsOfUse>
- NVD: This product uses data from the NVD API but is not endorsed or certified by the NVD. <https://nvd.nist.gov/vuln/detail/CVE-2025-36535>

HTML: <https://flawdb.com/CVE-2025-36535> · JSON: <https://flawdb.com/api/v1/entries/CVE-2025-36535>