CVE-2025-3606
Vestel AC Charger Exposure of Sensitive System Information to an Unauthorized Control Sphere
Mitigation
- Vendor workaround: Avoid using open network:
- * Use secure methods like virtual private networks (VPNs) for remote
- access. Regularly update VPNs to their latest versions and ensure that
- connected devices maintain strong security measures.
- * Reduce network exposure for applications and endpoints. Only make
- them accessible via the Internet if specifically designed for and
- required by their intended use.
- Login Credentials Management:
- * Force end user to revise the factory default set username and password of webconfig page.
- * Remove any printed documents such as installation guide, instruction
- book, quick start guide from web where login credentials are featured.
- Please refer to Vestel's advisory https://firebasestorage.googleapis.com/v0/b/vestel-shield.firebasestorage.app/o/PRODUCTION%2F1%2FVSA-1_R2.pdf for more information.
Who should check
- Anyone running Vestel AC Charger EVC04 3.75.0
Vulnerability facts
- Affected
- Vestel AC Charger EVC04 3.75.0
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, no login needed
- CVSS
- 8.7 (v4.0, CNA)CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:NOpen in CVSS calculator
Show all 11 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Attack requirements: None
- Privileges required: None
- User interaction: None
- Confidentiality impact: High
- Integrity impact: None
- Availability impact: None
- Confidentiality impact on other systems: None
- Integrity impact on other systems: None
- Availability impact on other systems: None
- EPSS
- 0.71% chance of exploitation in 30 days (percentile 49, 2026-11-26)
- CWE
- CWE-497
- Modified
Description
Vestel AC Charger version 3.75.0 contains a vulnerability that could enable an attacker to access files containing sensitive information, such as credentials which could be used to further compromise the device.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Vestel AC Charger EVC04 | 3.75.0 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2025-3606. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2025-3606.md Affected: Vestel AC Charger EVC04 3.75.0 Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Vestel AC Charger EVC04: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2025-3606 being exploited?
There is no confirmed exploitation: CVE-2025-3606 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.71% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2025-3606?
High: CVSS 8.7 (v4.0, scored by CNA). Remote, no login needed.
Which versions are affected by CVE-2025-3606?
Vestel AC Charger EVC04 3.75.0.
Is there a fix for CVE-2025-3606?
No fixed version is listed in the sources yet. Vendor workaround: Avoid using open network: * Use secure methods like virtual private networks (VPNs) for remote access. Regularly update VPNs to their latest versions and ensure that connected devices maintain strong security measures. * Reduce network exposure for applications and endpoints. Only make them accessible via the Internet if specifically designed for and required by their intended use. Login Credentials Management: * Force end user to revise the factory default set username and password of webconfig page. * Remove any printed documents such as installation guide, instruction book, quick start guide from web where login credentials are featured. Please refer to Vestel's advisory https://firebasestorage.googleapis.com/v0/b/vestel-shield.firebasestorage.app/o/PRODUCTION%2F1%2FVSA-1_R2.pdf for more information.
How do I check if I'm affected by CVE-2025-3606?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.