CVE-2025-34080
CONPROSYS HMI System (CHS) < 3.7.7 Reflected Cross-Site Scripting
Mitigation
- Upgrade CONPROSYS HMI System (CHS) to 3.7.7 or later.
Who should check
- Anyone running Contec Co.,Ltd. CONPROSYS HMI System (CHS) < 3.7.7
Vulnerability facts
- Affected
- Contec Co.,Ltd. CONPROSYS HMI System (CHS) < 3.7.7
- Fixed in
- Contec Co.,Ltd. CONPROSYS HMI System (CHS) 3.7.7
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, no login needed
- CVSS
- 5.1 (v4.0, CNA)CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:N/VA:N/SC:L/SI:L/SA:NOpen in CVSS calculator
Show all 11 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Attack requirements: None
- Privileges required: None
- User interaction: Active
- Confidentiality impact: None
- Integrity impact: None
- Availability impact: None
- Confidentiality impact on other systems: Low
- Integrity impact on other systems: Low
- Availability impact on other systems: None
- EPSS
- 1.39% chance of exploitation in 30 days (percentile 73, 2026-11-26)
- CWE
- CWE-79
- Modified
Description
The Contec Co.,Ltd. CONPROSYS HMI System (CHS) is vulnerable to Cross-Site Scripting (XSS) in the getqsetting.php functionality that could allow reflected execution of scripts in the browser on interaction.This issue affects CONPROSYS HMI System (CHS): before 3.7.7.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Contec Co.,Ltd. CONPROSYS HMI System (CHS) | < 3.7.7 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2025-34080. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2025-34080.md Affected: Contec Co.,Ltd. CONPROSYS HMI System (CHS) < 3.7.7 Fixed in: Contec Co.,Ltd. CONPROSYS HMI System (CHS) 3.7.7 Steps: 1. Search this machine and project for Contec Co.,Ltd. CONPROSYS HMI System (CHS): dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2025-34080 being exploited?
There is no confirmed exploitation: CVE-2025-34080 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 1.39% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2025-34080?
Medium: CVSS 5.1 (v4.0, scored by CNA). Remote, no login needed. A user has to take an action, such as opening a link, for the attack to work.
Which versions are affected by CVE-2025-34080?
Contec Co.,Ltd. CONPROSYS HMI System (CHS) < 3.7.7.
Is there a fix for CVE-2025-34080?
Yes. Fixed in Contec Co.,Ltd. CONPROSYS HMI System (CHS) 3.7.7. Upgrade CONPROSYS HMI System (CHS) to 3.7.7 or later.
How do I check if I'm affected by CVE-2025-34080?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.