# CVE-2025-32861: A vulnerability has been identified in TeleControl Server Basic (All versions \< V3.1.2.2). The affected application is…

> Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

- **Severity:** HIGH 8.7
- **CVSS:** 8.7 (v4.0, CNA) `CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N`
- **CVSS metrics:** Attack vector: Network; Attack complexity: Low; Attack requirements: None; Privileges required: Low; User interaction: None; Confidentiality impact: High; Integrity impact: High; Availability impact: High; Confidentiality impact on other systems: None; Integrity impact on other systems: None; Availability impact on other systems: None
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** None known
- **Remote exploitation:** Remote, login needed
- **EPSS:** 1.24% (percentile 69, 2026-11-26)
- **CWE:** CWE-89
- **Published:** 2025-04-16T17:38:44.533Z
- **Modified:** 2026-06-17T09:12:42.390Z

## Who should check

- Anyone running Siemens TeleControl Server Basic \< V3.1.2.2

## Description

A vulnerability has been identified in TeleControl Server Basic (All versions \< V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateTraceLevelSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

## Affected and fixed versions

- Siemens TeleControl Server Basic: \< V3.1.2.2 (cvelist)

## Mitigation

- No fix listed yet: follow the vendor advisory.

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2025-32861. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2025-32861.md
Affected: Siemens TeleControl Server Basic < V3.1.2.2
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Siemens TeleControl Server Basic: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2025-32861 being exploited?

There is no confirmed exploitation: CVE-2025-32861 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 1.24% chance of exploitation in the next 30 days (as of 2026-11-26).

### How serious is CVE-2025-32861?

High: CVSS 8.7 (v4.0, scored by CNA). Remote, login needed.

### Which versions are affected by CVE-2025-32861?

Siemens TeleControl Server Basic \< V3.1.2.2.

### Is there a fix for CVE-2025-32861?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

### How do I check if I'm affected by CVE-2025-32861?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- vendor: <https://cert-portal.siemens.com/productcert/html/ssa-443402.html>

## Attribution

- CVE Program: CVE® is a registered trademark of The MITRE Corporation. CVE records © 1999–2026 The MITRE Corporation. <https://www.cve.org/Legal/TermsOfUse>
- NVD: This product uses data from the NVD API but is not endorsed or certified by the NVD. <https://nvd.nist.gov/vuln/detail/CVE-2025-32861>

HTML: <https://flawdb.com/CVE-2025-32861> · JSON: <https://flawdb.com/api/v1/entries/CVE-2025-32861>
