CVE-2025-30421
Stack-based Buffer Overflow in DrObjectStorage::XML_Serialize() in NI Circuit Design Suite
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running NI Circuit Design Suite <= 14.3.0
Vulnerability facts
- Affected
- NI Circuit Design Suite <= 14.3.0
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Not remotely exploitable (local or adjacent access needed)
- CVSS
- 8.5 (v4.0, CNA)CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:NOpen in CVSS calculator
Show all 11 CVSS metrics
- Attack vector: Local
- Attack complexity: Low
- Attack requirements: None
- Privileges required: None
- User interaction: Passive
- Confidentiality impact: High
- Integrity impact: High
- Availability impact: High
- Confidentiality impact on other systems: None
- Integrity impact on other systems: None
- Availability impact on other systems: None
- EPSS
- 0.31% chance of exploitation in 30 days (percentile 16, 2026-11-26)
- CWE
- CWE-121
- Modified
Description
There is a memory corruption vulnerability due to a stack-based buffer overflow in DrObjectStorage::XML_Serialize() when using the SymbolEditor in NI Circuit Design Suite. This vulnerability may result in information disclosure or arbitrary code execution. Successful exploitation requires an attacker to get a user to open a specially crafted .sym file. This vulnerability affects NI Circuit Design Suite 14.3.0 and prior versions.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| NI Circuit Design Suite | <= 14.3.0 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2025-30421. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2025-30421.md Affected: NI Circuit Design Suite <= 14.3.0 Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for NI Circuit Design Suite: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2025-30421 being exploited?
There is no confirmed exploitation: CVE-2025-30421 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.31% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2025-30421?
High: CVSS 8.5 (v4.0, scored by CNA). Not remotely exploitable (local or adjacent access needed). A user has to take an action, such as opening a link, for the attack to work.
Which versions are affected by CVE-2025-30421?
NI Circuit Design Suite <= 14.3.0.
Is there a fix for CVE-2025-30421?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2025-30421?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.