Skip to content
FlawDB
Sign in
Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

CVE-2025-3020

MEDIUM 5.4EPSS 37%

Wiesemann & Theis: Multiple W&T Products are vulnerable to cross-site-scripting

Mitigation

  • Upgrade Web-Count 6x Digital to 3.79 or later.
  • Upgrade Web-IO Digital 12xIn, 12xOut to 4.08 or later.
  • Upgrade Web-IO Digital Logger 6xIn, 6xOut to 3.70 or later.

Who should check

  • Anyone running Wiesemann & Theis ERP-Gateway 12x Digital Input, 6x Digital Relais all
  • Anyone running Wiesemann & Theis ERP-Gateway 2x Digital Input, 2x Digital Output all
  • Anyone running Wiesemann & Theis ERP-Gateway 2x Digital PoE all
  • Anyone running Wiesemann & Theis Web-Alarm 6x6 DigitalWeb-Alarm 6x6 Digital all
  • Anyone running Wiesemann & Theis Web-Count 6x Digital < 3.79
  • Anyone running Wiesemann & Theis Web-Graph Air Quality all
  • Anyone running Wiesemann & Theis Web-IO 12x Digital Input, 6x Digital Relais all
  • Anyone running Wiesemann & Theis Web-IO Analog-In/Out 2x 0/4..20mA PoE all

Vulnerability facts

Affected
Wiesemann & Theis ERP-Gateway 12x Digital Input, 6x Digital Relais all; Wiesemann & Theis ERP-Gateway 2x Digital Input, 2x Digital Output all; Wiesemann & Theis ERP-Gateway 2x Digital PoE all; Wiesemann & Theis Web-Alarm 6x6 DigitalWeb-Alarm 6x6 Digital all; Wiesemann & Theis Web-Count 6x Digital < 3.79; Wiesemann & Theis Web-Graph Air Quality all; Wiesemann & Theis Web-IO 12x Digital Input, 6x Digital Relais all; Wiesemann & Theis Web-IO 12x Digital Input, 6x Digital Relais all; Wiesemann & Theis Web-IO 12x Digital Input, 6x Digital Relais all; Wiesemann & Theis Web-IO Analog-In/Out 2x 0/4..20mA PoE all; Wiesemann & Theis Web-IO Digital 12xIn, 12xOut all; Wiesemann & Theis Web-IO Digital 12xIn, 12xOut all; Wiesemann & Theis Web-IO Digital 12xIn, 12xOut < 4.08; Wiesemann & Theis Web-IO Digital 12xIn, 12xOut, 1xRS232 all; Wiesemann & Theis Web-IO Digital 12xIn, 12xOut, 1xRS232 all; Wiesemann & Theis Web-IO Digital 2xIn, 2xOut all; Wiesemann & Theis Web-IO Digital 2xIn, 2xOut all; Wiesemann & Theis Web-IO Digital 2xIn, 2xOut all; Wiesemann & Theis Web-IO Digital Logger 6xIn, 6xOut < 3.70; Wiesemann & Theis Web-Thermograph 2x all; Wiesemann & Theis Web-Thermograph 8x all; Wiesemann & Theis Web-Thermograph NTC all; Wiesemann & Theis Web-Thermograph NTC PoE all; Wiesemann & Theis Web-Thermograph Pt100 / Pt1000 all; Wiesemann & Theis Web-Thermograph Pt100 / Pt1000 PoE all; Wiesemann & Theis Web-Thermograph Relais all; Wiesemann & Theis Web-Thermo-Hygrobarograph all; Wiesemann & Theis Web-Thermo-Hygrograph all
Fixed in
Wiesemann & Theis Web-Count 6x Digital 3.79, Wiesemann & Theis Web-IO Digital 12xIn, 12xOut 4.08, Wiesemann & Theis Web-IO Digital Logger 6xIn, 6xOut 3.70
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Remote, no login needed
CVSS
5.4 (v3.1, CNA)CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:NOpen in CVSS calculator
Show all 8 CVSS metrics
  • Attack vector: Network
  • Attack complexity: Low
  • Privileges required: None
  • User interaction: Required
  • Scope: Unchanged
  • Confidentiality impact: Low
  • Integrity impact: Low
  • Availability impact: None
EPSS
0.51% chance of exploitation in 30 days (percentile 37, 2026-11-26)
CWE
CWE-79
Published
Modified

Description

An low privileged remote Attacker can execute arbitrary web scripts or HTML via a crafted payload injected into several fields of the configuration webpage with limited impact.

Affected and fixed versions

Package / productAffectedFixedSource
Wiesemann & Theis ERP-Gateway 12x Digital Input, 6x Digital Relaisall—cvelist
Wiesemann & Theis ERP-Gateway 2x Digital Input, 2x Digital Outputall—cvelist
Wiesemann & Theis ERP-Gateway 2x Digital PoEall—cvelist
Wiesemann & Theis Web-Alarm 6x6 DigitalWeb-Alarm 6x6 Digitalall—cvelist
Wiesemann & Theis Web-Count 6x Digital< 3.79—cvelist
Wiesemann & Theis Web-Graph Air Qualityall—cvelist
Wiesemann & Theis Web-IO 12x Digital Input, 6x Digital Relaisall—cvelist
Wiesemann & Theis Web-IO 12x Digital Input, 6x Digital Relaisall—cvelist
Wiesemann & Theis Web-IO 12x Digital Input, 6x Digital Relaisall—cvelist
Wiesemann & Theis Web-IO Analog-In/Out 2x 0/4..20mA PoEall—cvelist
Wiesemann & Theis Web-IO Digital 12xIn, 12xOutall—cvelist
Wiesemann & Theis Web-IO Digital 12xIn, 12xOutall—cvelist
Wiesemann & Theis Web-IO Digital 12xIn, 12xOut< 4.08—cvelist
Wiesemann & Theis Web-IO Digital 12xIn, 12xOut, 1xRS232all—cvelist
Wiesemann & Theis Web-IO Digital 12xIn, 12xOut, 1xRS232all—cvelist
Wiesemann & Theis Web-IO Digital 2xIn, 2xOutall—cvelist
Wiesemann & Theis Web-IO Digital 2xIn, 2xOutall—cvelist
Wiesemann & Theis Web-IO Digital 2xIn, 2xOutall—cvelist
Wiesemann & Theis Web-IO Digital Logger 6xIn, 6xOut< 3.70—cvelist
Wiesemann & Theis Web-Thermograph 2xall—cvelist
Wiesemann & Theis Web-Thermograph 8xall—cvelist
Wiesemann & Theis Web-Thermograph NTCall—cvelist
Wiesemann & Theis Web-Thermograph NTC PoEall—cvelist
Wiesemann & Theis Web-Thermograph Pt100 / Pt1000all—cvelist
Wiesemann & Theis Web-Thermograph Pt100 / Pt1000 PoEall—cvelist
Wiesemann & Theis Web-Thermograph Relaisall—cvelist
Wiesemann & Theis Web-Thermo-Hygrobarographall—cvelist
Wiesemann & Theis Web-Thermo-Hygrographall—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2025-3020. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2025-3020.md
Affected: Wiesemann & Theis ERP-Gateway 12x Digital Input, 6x Digital Relais all; Wiesemann & Theis ERP-Gateway 2x Digital Input, 2x Digital Output all; Wiesemann & Theis ERP-Gateway 2x Digital PoE all; Wiesemann & Theis Web-Alarm 6x6 DigitalWeb-Alarm 6x6 Digital all; Wiesemann & Theis Web-Count 6x Digital <…
Fixed in: Wiesemann & Theis Web-Count 6x Digital 3.79, Wiesemann & Theis Web-IO Digital 12xIn, 12xOut 4.08, Wiesemann & Theis Web-IO Digital Logger 6xIn, 6xOut 3.70

Steps:
1. Search this machine and project for Wiesemann & Theis ERP-Gateway 12x Digital Input, 6x Digital Relais, Wiesemann & Theis ERP-Gateway 2x Digital Input, 2x Digital Output, Wiesemann & Theis ERP-Gateway 2x Digital PoE, Wiesemann & Theis Web-Alarm 6x6 DigitalWeb-Alarm 6x6 Digital, Wiesemann & Theis Web-Count 6x Digital, Wiesemann & Thei…: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2025-3020 being exploited?

There is no confirmed exploitation: CVE-2025-3020 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.51% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2025-3020?

Medium: CVSS 5.4 (v3.1, scored by CNA). Remote, no login needed. A user has to take an action, such as opening a link, for the attack to work.

Which versions are affected by CVE-2025-3020?

Wiesemann & Theis ERP-Gateway 12x Digital Input, 6x Digital Relais all; Wiesemann & Theis ERP-Gateway 2x Digital Input, 2x Digital Output all; Wiesemann & Theis ERP-Gateway 2x Digital PoE all; Wiesemann & Theis Web-Alarm 6x6 DigitalWeb-Alarm 6x6 Digital all; Wiesemann & Theis Web-Count 6x Digital < 3.79; Wiesemann & Theis Web-Graph Air Quality all; Wiesemann & Theis Web-IO 12x Digital Input, 6x Digital Relais all; Wiesemann & Theis Web-IO 12x Digital Input, 6x Digital Relais all; Wiesemann & Theis Web-IO 12x Digital Input, 6x Digital Relais all; Wiesemann & Theis Web-IO Analog-In/Out 2x 0/4..20mA PoE all; Wiesemann & Theis Web-IO Digital 12xIn, 12xOut all; Wiesemann & Theis Web-IO Digital 12xIn, 12xOut all; Wiesemann & Theis Web-IO Digital 12xIn, 12xOut < 4.08; Wiesemann & Theis Web-IO Digital 12xIn, 12xOut, 1xRS232 all; Wiesemann & Theis Web-IO Digital 12xIn, 12xOut, 1xRS232 all; Wiesemann & Theis Web-IO Digital 2xIn, 2xOut all; Wiesemann & Theis Web-IO Digital 2xIn, 2xOut all; Wiesemann & Theis Web-IO Digital 2xIn, 2xOut all; Wiesemann & Theis Web-IO Digital Logger 6xIn, 6xOut < 3.70; Wiesemann & Theis Web-Thermograph 2x all; Wiesemann & Theis Web-Thermograph 8x all; Wiesemann & Theis Web-Thermograph NTC all; Wiesemann & Theis Web-Thermograph NTC PoE all; Wiesemann & Theis Web-Thermograph Pt100 / Pt1000 all; Wiesemann & Theis Web-Thermograph Pt100 / Pt1000 PoE all; Wiesemann & Theis Web-Thermograph Relais all; Wiesemann & Theis Web-Thermo-Hygrobarograph all; Wiesemann & Theis Web-Thermo-Hygrograph all.

Is there a fix for CVE-2025-3020?

Yes. Fixed in Wiesemann & Theis Web-Count 6x Digital 3.79, Wiesemann & Theis Web-IO Digital 12xIn, 12xOut 4.08, Wiesemann & Theis Web-IO Digital Logger 6xIn, 6xOut 3.70. Upgrade Web-Count 6x Digital to 3.79 or later. Upgrade Web-IO Digital 12xIn, 12xOut to 4.08 or later. Upgrade Web-IO Digital Logger 6xIn, 6xOut to 3.70 or later.

How do I check if I'm affected by CVE-2025-3020?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors