CVE-2025-27594
Unencrypted transmission of password hash
Mitigation
- Vendor workaround: Please make sure that you apply general security practices when operating the products. The following General Security Practices and Operating Guidelines could mitigate the associated security risk.
Who should check
- Anyone running SICK AG SICK DL100-2xxxxxxx all versions
Vulnerability facts
- Affected
- SICK AG SICK DL100-2xxxxxxx all versions
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, no login needed
- CVSS
- 7.5 (v3.1, CNA)CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:NOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Privileges required: None
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: High
- Integrity impact: None
- Availability impact: None
- EPSS
- 0.63% chance of exploitation in 30 days (percentile 44, 2026-11-26)
- CWE
- CWE-319
- Modified
Description
The device uses an unencrypted, proprietary protocol for communication. Through this protocol, configuration data is transmitted and device authentication is performed. An attacker can thereby intercept the authentication hash and use it to log into the device using a pass-the-hash attack.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| SICK AG SICK DL100-2xxxxxxx | all versions | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2025-27594. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2025-27594.md Affected: SICK AG SICK DL100-2xxxxxxx all versions Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for SICK AG SICK DL100-2xxxxxxx: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
Vendor advisories
Other
- https://sick.com/psirt
- https://cdn.sick.com/media/docs/1/11/411/Special_information_CYBERSECURITY_BY_SICK_en_IM0084411.PDF
- https://www.cisa.gov/resources-tools/resources/ics-recommended-practices
- https://www.first.org/cvss/calculator/3.1
- https://github.security.telekom.com/2025/03/multiple-vulnerabilities-in-sick-dl100.html
FAQ
Is CVE-2025-27594 being exploited?
There is no confirmed exploitation: CVE-2025-27594 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.63% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2025-27594?
High: CVSS 7.5 (v3.1, scored by CNA). Remote, no login needed.
Which versions are affected by CVE-2025-27594?
SICK AG SICK DL100-2xxxxxxx all versions.
Is there a fix for CVE-2025-27594?
No fixed version is listed in the sources yet. Vendor workaround: Please make sure that you apply general security practices when operating the products. The following General Security Practices and Operating Guidelines could mitigate the associated security risk.
How do I check if I'm affected by CVE-2025-27594?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.