CVE-2025-26856
Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in UD-LT2 firmw…
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running I-O DATA DEVICE, INC. UD-LT2 firmware Ver.1.00.008_SE and earlier
Vulnerability facts
- Affected
- I-O DATA DEVICE, INC. UD-LT2 firmware Ver.1.00.008_SE and earlier
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, login needed
- CVSS
- 7.2 (v3.0, CNA)CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Privileges required: High
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: High
- Integrity impact: High
- Availability impact: High
- EPSS
- 2.09% chance of exploitation in 30 days (percentile 82, 2026-11-26)
- CWE
- CWE-78
- Modified
Description
Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in UD-LT2 firmware Ver.1.00.008_SE and earlier. If an attacker logs in to the affected product with an administrative account and manipulates requests for a certain screen operation, an arbitrary OS command may be executed. This vulnerability was reported on a different screen operation from CVE-2025-20617.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| I-O DATA DEVICE, INC. UD-LT2 | firmware Ver.1.00.008_SE and earlier | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2025-26856. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2025-26856.md Affected: I-O DATA DEVICE, INC. UD-LT2 firmware Ver.1.00.008_SE and earlier Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for I-O DATA DEVICE, INC. UD-LT2: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2025-26856 being exploited?
There is no confirmed exploitation: CVE-2025-26856 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 2.09% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2025-26856?
High: CVSS 7.2 (v3.0, scored by CNA). Remote, login needed.
Which versions are affected by CVE-2025-26856?
I-O DATA DEVICE, INC. UD-LT2 firmware Ver.1.00.008_SE and earlier.
Is there a fix for CVE-2025-26856?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2025-26856?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.