CVE-2025-26389
A vulnerability has been identified in OZW672 (All versions < V8.0), OZW772 (All versions < V8.0). The web service in a…
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Siemens OZW672 < V8.0
- Anyone running Siemens OZW772 < V8.0
Vulnerability facts
- Affected
- Siemens OZW672 < V8.0; Siemens OZW772 < V8.0
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, no login needed
- CVSS
- 10.0 (v4.0, CNA)CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:HOpen in CVSS calculator
Show all 11 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Attack requirements: None
- Privileges required: None
- User interaction: None
- Confidentiality impact: High
- Integrity impact: High
- Availability impact: High
- Confidentiality impact on other systems: High
- Integrity impact on other systems: High
- Availability impact on other systems: High
- EPSS
- 1.66% chance of exploitation in 30 days (percentile 77, 2026-11-26)
- CWE
- CWE-78
- Modified
Description
A vulnerability has been identified in OZW672 (All versions < V8.0), OZW772 (All versions < V8.0). The web service in affected devices does not sanitize the input parameters required for the `exportDiagramPage` endpoint. This could allow an unauthenticated remote attacker to execute arbitrary code with root privileges.
Affected and fixed versions
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2025-26389. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2025-26389.md Affected: Siemens OZW672 < V8.0; Siemens OZW772 < V8.0 Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Siemens OZW672, Siemens OZW772: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
Vendor advisories
FAQ
Is CVE-2025-26389 being exploited?
There is no confirmed exploitation: CVE-2025-26389 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 1.66% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2025-26389?
Critical: CVSS 10.0 (v4.0, scored by CNA). Remote, no login needed.
Which versions are affected by CVE-2025-26389?
Siemens OZW672 < V8.0; Siemens OZW772 < V8.0.
Is there a fix for CVE-2025-26389?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2025-26389?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.