# CVE-2025-24481: FactoryTalk® View Site Edition - Incorrect Permission Assignment

> Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

- **Severity:** HIGH 7.0
- **CVSS:** 7.0 (v4.0, CNA) `CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:H/SC:N/SI:N/SA:N`
- **CVSS metrics:** Attack vector: Local; Attack complexity: Low; Attack requirements: None; Privileges required: None; User interaction: None; Confidentiality impact: Low; Integrity impact: Low; Availability impact: High; Confidentiality impact on other systems: None; Integrity impact on other systems: None; Availability impact on other systems: None
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** None known
- **Remote exploitation:** Not remotely exploitable (local or adjacent access needed)
- **EPSS:** 0.26% (percentile 11, 2026-11-26)
- **CWE:** CWE-732
- **Published:** 2025-01-28T20:55:54.833Z
- **Modified:** 2026-06-17T08:59:05.797Z

## Who should check

- Anyone running Rockwell Automation FactoryTalk® View Site Edition \<V15

## Description

An Incorrect Permission Assignment Vulnerability exists in the product and version listed above. The vulnerability is due to incorrect permissions being assigned to the remote debugger port and can allow for unauthenticated access to the system configuration.

## Affected and fixed versions

- Rockwell Automation FactoryTalk® View Site Edition: \<V15 (cvelist)

## Mitigation

- Vendor workaround: Protect physical access to the workstation & restrict access to port 8091 at the network or workstation.

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2025-24481. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2025-24481.md
Affected: Rockwell Automation FactoryTalk® View Site Edition <V15
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Rockwell Automation FactoryTalk® View Site Edition: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2025-24481 being exploited?

There is no confirmed exploitation: CVE-2025-24481 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.26% chance of exploitation in the next 30 days (as of 2026-11-26).

### How serious is CVE-2025-24481?

High: CVSS 7.0 (v4.0, scored by CNA). Not remotely exploitable (local or adjacent access needed).

### Which versions are affected by CVE-2025-24481?

Rockwell Automation FactoryTalk® View Site Edition \<V15.

### Is there a fix for CVE-2025-24481?

No fixed version is listed in the sources yet. Vendor workaround: Protect physical access to the workstation & restrict access to port 8091 at the network or workstation.

### How do I check if I'm affected by CVE-2025-24481?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- other: <https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1720.html>

## Attribution

- CVE Program: CVE® is a registered trademark of The MITRE Corporation. CVE records © 1999–2026 The MITRE Corporation. <https://www.cve.org/Legal/TermsOfUse>
- NVD: This product uses data from the NVD API but is not endorsed or certified by the NVD. <https://nvd.nist.gov/vuln/detail/CVE-2025-24481>

HTML: <https://flawdb.com/CVE-2025-24481> · JSON: <https://flawdb.com/api/v1/entries/CVE-2025-24481>