CVE-2025-14858
Semtech LR11xx Encrypted Firmware Disclosure
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Semtech LR1110 < TRX FW 0x0402
- Anyone running Semtech LR1120 < TRX FW 0x0202
- Anyone running Semtech LR1121 < TRX FW 0x0104
Vulnerability facts
- Affected
- Semtech LR1110 < TRX FW 0x0402; Semtech LR1120 < TRX FW 0x0202; Semtech LR1121 < TRX FW 0x0104
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Not remotely exploitable (local or adjacent access needed)
- CVSS
- 5.1 (v4.0, CNA)CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/AU:N/R:A/V:C/RE:MOpen in CVSS calculator
Show all 15 CVSS metrics
- Attack vector: Physical
- Attack complexity: Low
- Attack requirements: None
- Privileges required: None
- User interaction: None
- Confidentiality impact: High
- Integrity impact: None
- Availability impact: None
- Confidentiality impact on other systems: None
- Integrity impact on other systems: None
- Availability impact on other systems: None
- AU: N
- R: A
- V: C
- RE: M
- EPSS
- 0.14% chance of exploitation in 30 days (percentile 2, 2026-11-26)
- CWE
- CWE-226
- Modified
Description
The Semtech LR11xx LoRa transceivers running early versions of firmware contains an information disclosure vulnerability in its firmware validation functionality. When a host issues a firmware validity check command via the SPI interface, the device decrypts the provided encrypted firmware package block-by-block to validate its integrity. However, the last decrypted firmware block remains uncleared in memory after the validation process completes. An attacker with access to the SPI interface can subsequently issue memory read commands to retrieve the decrypted firmware contents from this residual memory, effectively bypassing the firmware encryption protection mechanism. The attack requires physical access to the device's SPI interface.
Affected and fixed versions
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2025-14858. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2025-14858.md Affected: Semtech LR1110 < TRX FW 0x0402; Semtech LR1120 < TRX FW 0x0202; Semtech LR1121 < TRX FW 0x0104 Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Semtech LR1110, Semtech LR1120, Semtech LR1121: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2025-14858 being exploited?
There is no confirmed exploitation: CVE-2025-14858 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.14% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2025-14858?
Medium: CVSS 5.1 (v4.0, scored by CNA). Not remotely exploitable (local or adjacent access needed).
Which versions are affected by CVE-2025-14858?
Semtech LR1110 < TRX FW 0x0402; Semtech LR1120 < TRX FW 0x0202; Semtech LR1121 < TRX FW 0x0104.
Is there a fix for CVE-2025-14858?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2025-14858?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.