CVE-2025-13605
Shell command injection in 3onedata GW1101-1D(RS-485)-TB-P modbus gateway
Mitigation
- Upgrade GW1101-1D(RS-485)-TB-P to 3.0.59B2024080600R4353 or later.
Who should check
- Anyone running 3onedata GW1101-1D(RS-485)-TB-P < 3.0.59B2024080600R4353
Vulnerability facts
- Affected
- 3onedata GW1101-1D(RS-485)-TB-P < 3.0.59B2024080600R4353
- Fixed in
- 3onedata GW1101-1D(RS-485)-TB-P 3.0.59B2024080600R4353
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Not remotely exploitable (local or adjacent access needed)
- CVSS
- 9.3 (v4.0, CNA)CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:HOpen in CVSS calculator
Show all 11 CVSS metrics
- Attack vector: Adjacent network
- Attack complexity: Low
- Attack requirements: None
- Privileges required: High
- User interaction: None
- Confidentiality impact: High
- Integrity impact: High
- Availability impact: High
- Confidentiality impact on other systems: High
- Integrity impact on other systems: High
- Availability impact on other systems: High
- EPSS
- 0.30% chance of exploitation in 30 days (percentile 16, 2026-11-26)
- CWE
- CWE-78
- Modified
Description
3onedata modbus gateway device model GW1101-1D(RS-485)-TB-P (hardware version V2.2.0) allows authenticated users to execute arbitrary shell commands in the context of the root user by providing payload in the "IP address" field of the diagnosis test tools. This issue has been resolved in firmware version 3.0.59B2024080600R4353
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| 3onedata GW1101-1D(RS-485)-TB-P | < 3.0.59B2024080600R4353 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2025-13605. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2025-13605.md Affected: 3onedata GW1101-1D(RS-485)-TB-P < 3.0.59B2024080600R4353 Fixed in: 3onedata GW1101-1D(RS-485)-TB-P 3.0.59B2024080600R4353 Steps: 1. Search this machine and project for 3onedata GW1101-1D(RS-485)-TB-P: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2025-13605 being exploited?
There is no confirmed exploitation: CVE-2025-13605 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.30% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2025-13605?
Critical: CVSS 9.3 (v4.0, scored by CNA). Not remotely exploitable (local or adjacent access needed).
Which versions are affected by CVE-2025-13605?
3onedata GW1101-1D(RS-485)-TB-P < 3.0.59B2024080600R4353.
Is there a fix for CVE-2025-13605?
Yes. Fixed in 3onedata GW1101-1D(RS-485)-TB-P 3.0.59B2024080600R4353. Upgrade GW1101-1D(RS-485)-TB-P to 3.0.59B2024080600R4353 or later.
How do I check if I'm affected by CVE-2025-13605?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.