# CVE-2025-1204: The "update" binary in the firmware of the affected product sends attempts to mount to a hard-coded, routable IP addres…

> Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

- **Severity:** HIGH 7.7
- **CVSS:** 7.7 (v4.0, CNA) `CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N`
- **CVSS metrics:** Attack vector: Network; Attack complexity: Low; Attack requirements: Present; Privileges required: None; User interaction: Passive; Confidentiality impact: High; Integrity impact: High; Availability impact: High; Confidentiality impact on other systems: None; Integrity impact on other systems: None; Availability impact on other systems: None
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** None known
- **Remote exploitation:** Remote, no login needed
- **EPSS:** 0.77% (percentile 52, 2026-11-26)
- **CWE:** CWE-912
- **Published:** 2025-02-25T17:00:16.133Z
- **Modified:** 2026-06-17T08:38:35.903Z

## Who should check

- Anyone running Contec Health CMS8000 Patient Monitor (versions: see the vendor advisory)

## Description

The "update" binary in the firmware of the affected product sends attempts to mount to a hard-coded, routable IP address, bypassing existing device network settings to do so. The function triggers if the 'C' button is pressed at a specific time during the boot process. If an attacker is able to control or impersonate this IP address, they could upload and overwrite files on the device.

## Affected and fixed versions

- Contec Health CMS8000 Patient Monitor: see vendor advisory (cvelist)

## Mitigation

- Vendor workaround: Per FDA recommendation, CISA recommends users remove any Contec CMS8000 devices from their networks.
- 
- If asset owners cannot remove the devices from their networks, users should block 202.114.4.0/24 from their networks, or block 202.114.4.119 and 202.114.4.120.

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2025-1204. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2025-1204.md
Affected: Contec Health CMS8000 Patient Monitor
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Contec Health CMS8000 Patient Monitor: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2025-1204 being exploited?

There is no confirmed exploitation: CVE-2025-1204 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.77% chance of exploitation in the next 30 days (as of 2026-11-26).

### How serious is CVE-2025-1204?

High: CVSS 7.7 (v4.0, scored by CNA). Remote, no login needed. A user has to take an action, such as opening a link, for the attack to work.

### Which versions are affected by CVE-2025-1204?

Contec Health CMS8000 Patient Monitor.

### Is there a fix for CVE-2025-1204?

No fixed version is listed in the sources yet. Vendor workaround: Per FDA recommendation, CISA recommends users remove any Contec CMS8000 devices from their networks.  If asset owners cannot remove the devices from their networks, users should block 202.114.4.0/24 from their networks, or block 202.114.4.119 and 202.114.4.120.

### How do I check if I'm affected by CVE-2025-1204?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- other: <https://claroty.com/team82/research/are-contec-cms8000-patient-monitors-infected-with-a-chinese-backdoor-the-reality-is-more-complicated?ref=vault33.org>
- other: <https://www.cisa.gov/news-events/ics-medical-advisories/icsma-25-030-01>

## Attribution

- CVE Program: CVE® is a registered trademark of The MITRE Corporation. CVE records © 1999–2026 The MITRE Corporation. <https://www.cve.org/Legal/TermsOfUse>
- NVD: This product uses data from the NVD API but is not endorsed or certified by the NVD. <https://nvd.nist.gov/vuln/detail/CVE-2025-1204>

HTML: <https://flawdb.com/CVE-2025-1204> · JSON: <https://flawdb.com/api/v1/entries/CVE-2025-1204>
