CVE-2025-10546
Cross-Site Scripting (XSS) Vulnerability in PPC XPON ONT Wi-Fi Router
Mitigation
- Vendor workaround: i. Disable remote management
- ii. Restrict admin access to trusted LAN devices only
- iii. Avoid accessing the management UI via untrusted links
Who should check
- Anyone running PPC Technologies PPC XPON ONT (Optical Network Terminal) 2K15X v2.3.15PPCL; v1.0.3
Vulnerability facts
- Affected
- PPC Technologies PPC XPON ONT (Optical Network Terminal) 2K15X v2.3.15PPCL; v1.0.3
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, no login needed
- CVSS
- 5.1 (v4.0, CNA)CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:L/VI:L/VA:N/SC:L/SI:L/SA:NOpen in CVSS calculator
Show all 11 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Attack requirements: None
- Privileges required: None
- User interaction: Active
- Confidentiality impact: Low
- Integrity impact: Low
- Availability impact: None
- Confidentiality impact on other systems: Low
- Integrity impact on other systems: Low
- Availability impact on other systems: None
- EPSS
- 0.70% chance of exploitation in 30 days (percentile 49, 2026-11-26)
- CWE
- CWE-79
- Modified
Description
This vulnerability exist in PPC 2K15X Router, due to improper input validation for the Common Gateway Interface (CGI) parameters at its web management portal. A remote attacker could exploit this vulnerability by injecting malicious JavaScript into the vulnerable parameter, leading to a reflected Cross-Site Scripting (XSS) attack on the targeted system.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| PPC Technologies PPC XPON ONT (Optical Network Terminal) 2K15X | v2.3.15PPCL; v1.0.3 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2025-10546. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2025-10546.md Affected: PPC Technologies PPC XPON ONT (Optical Network Terminal) 2K15X v2.3.15PPCL; v1.0.3 Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for PPC Technologies PPC XPON ONT (Optical Network Terminal) 2K15X: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2025-10546 being exploited?
There is no confirmed exploitation: CVE-2025-10546 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.70% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2025-10546?
Medium: CVSS 5.1 (v4.0, scored by CNA). Remote, no login needed. A user has to take an action, such as opening a link, for the attack to work.
Which versions are affected by CVE-2025-10546?
PPC Technologies PPC XPON ONT (Optical Network Terminal) 2K15X v2.3.15PPCL; v1.0.3.
Is there a fix for CVE-2025-10546?
No fixed version is listed in the sources yet. Vendor workaround: i. Disable remote management ii. Restrict admin access to trusted LAN devices only iii. Avoid accessing the management UI via untrusted links
How do I check if I'm affected by CVE-2025-10546?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.