CVE-2025-10150
Webserver crash caused by scanning on TCP port 80
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Softing Industrial Automation GmbH smartLink HW-PN >= 1.02, <= 1.03
- Anyone running Softing Industrial Automation GmbH smartLink HW-DP <= 1.31
Vulnerability facts
- Affected
- Softing Industrial Automation GmbH smartLink HW-PN >= 1.02, <= 1.03; Softing Industrial Automation GmbH smartLink HW-DP <= 1.31
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, no login needed
- CVSS
- 8.7 (v4.0, CNA)CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:L/AU:Y/R:U/RE:M/U:AmberOpen in CVSS calculator
Show all 15 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Attack requirements: None
- Privileges required: None
- User interaction: None
- Confidentiality impact: None
- Integrity impact: None
- Availability impact: High
- Confidentiality impact on other systems: None
- Integrity impact on other systems: None
- Availability impact on other systems: Low
- AU: Y
- R: U
- RE: M
- U: Amber
- EPSS
- 0.45% chance of exploitation in 30 days (percentile 31, 2026-11-26)
- CWE
- CWE-833
- Modified
Description
Webserver crash caused by scanning on TCP port 80 in Softing Industrial Automation GmbH gateways and switch.This issue affects smartLink HW-PN: from 1.02 through 1.03 smartLink HW-DP: 1.31
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Softing Industrial Automation GmbH smartLink HW-PN | >= 1.02, <= 1.03 | — | cvelist |
| Softing Industrial Automation GmbH smartLink HW-DP | <= 1.31 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2025-10150. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2025-10150.md Affected: Softing Industrial Automation GmbH smartLink HW-PN >= 1.02, <= 1.03; Softing Industrial Automation GmbH smartLink HW-DP <= 1.31 Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Softing Industrial Automation GmbH smartLink HW-PN, Softing Industrial Automation GmbH smartLink HW-DP: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2025-10150 being exploited?
There is no confirmed exploitation: CVE-2025-10150 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.45% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2025-10150?
High: CVSS 8.7 (v4.0, scored by CNA). Remote, no login needed.
Which versions are affected by CVE-2025-10150?
Softing Industrial Automation GmbH smartLink HW-PN >= 1.02, <= 1.03; Softing Industrial Automation GmbH smartLink HW-DP <= 1.31.
Is there a fix for CVE-2025-10150?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2025-10150?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.