Exposure of Private Personal Information to an Unauthorized Actor vulnerability in Contec Health CMS8000 Patient Monitor
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Contec Health CMS8000 Patient Monitor All versions
Vulnerability facts
- Affected
- Contec Health CMS8000 Patient Monitor All versions
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, no login needed
- CVSS
- 8.2 (v4.0, CNA)CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:NOpen in CVSS calculator
Show all 11 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Attack requirements: Present
- Privileges required: None
- User interaction: None
- Confidentiality impact: High
- Integrity impact: None
- Availability impact: None
- Confidentiality impact on other systems: None
- Integrity impact on other systems: None
- Availability impact on other systems: None
- EPSS
- 0.84% chance of exploitation in 30 days (percentile 55, 2026-11-26)
- CWE
- CWE-359
- Modified
Description
In its default configuration, Contec Health CMS8000 Patient Monitor transmits plain-text patient data to a hard-coded public IP address when a patient is hooked up to the monitor. This could lead to a leakage of confidential patient data to any device with that IP address or an attacker in a machine-in-the-middle scenario.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Contec Health CMS8000 Patient Monitor | All versions | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2025-0683. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2025-0683.md Affected: Contec Health CMS8000 Patient Monitor All versions Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Contec Health CMS8000 Patient Monitor: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
Other
- https://www.cisa.gov/news-events/ics-medical-advisories/icsma-25-030-01
- https://www.fda.gov/medical-devices/safety-communications/cybersecurity-vulnerabilities-certain-patient-monitors-contec-and-epsimed-fda-safety-communication
- https://www.cisa.gov/resources-tools/resources/contec-cms8000-contains-backdoor
- https://www.bleepingcomputer.com/news/security/backdoor-found-in-two-healthcare-patient-monitors-linked-to-ip-in-china/
FAQ
Is CVE-2025-0683 being exploited?
There is no confirmed exploitation: CVE-2025-0683 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.84% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2025-0683?
High: CVSS 8.2 (v4.0, scored by CNA). Remote, no login needed.
Which versions are affected by CVE-2025-0683?
Contec Health CMS8000 Patient Monitor All versions.
Is there a fix for CVE-2025-0683?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2025-0683?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.