# CVE-2025-0626: Hidden Functionality vulnerability in Contec Health CMS8000 Patient Monitor

> Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

- **Severity:** HIGH 7.7
- **CVSS:** 7.7 (v4.0, CNA) `CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N`
- **CVSS metrics:** Attack vector: Network; Attack complexity: Low; Attack requirements: Present; Privileges required: None; User interaction: Passive; Confidentiality impact: High; Integrity impact: High; Availability impact: High; Confidentiality impact on other systems: None; Integrity impact on other systems: None; Availability impact on other systems: None
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** None known
- **Remote exploitation:** Remote, no login needed
- **EPSS:** 0.95% (percentile 60, 2026-11-26)
- **CWE:** CWE-912
- **Published:** 2025-01-30T18:17:29.717Z
- **Modified:** 2026-06-17T08:26:51.603Z

## Who should check

- Anyone running Contec Health CMS8000 Patient Monitor All versions

## Description

The "monitor" binary in the firmware of the affected product attempts to mount to a hard-coded, routable IP address, bypassing existing device network settings to do so. The function also enables the network interface of the device if it is disabled. The function is triggered by attempting to update the device from the user menu. This could serve as a backdoor to the device, and could lead to a malicious actor being able to upload and overwrite files on the device.

## Affected and fixed versions

- Contec Health CMS8000 Patient Monitor: All versions (cvelist)

## Mitigation

- Vendor workaround: Per FDA recommendation, CISA recommends users remove any Contec CMS8000 devices from their networks.
- 
- If asset owners cannot remove the devices from their networks, users should block 202.114.4.0/24 from their networks, or block 202.114.4.119 and 202.114.4.120.
- 
- Please note that this device may be re-labeled and sold by resellers. For a list of known re-labeled devices, please refer to FDA's  safety communication https://www.fda.gov/medical-devices/safety-communications/cybersecurity-vulnerabilities-certain-patient-monitors-contec-and-epsimed-fda-safety-communication .

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2025-0626. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2025-0626.md
Affected: Contec Health CMS8000 Patient Monitor All versions
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Contec Health CMS8000 Patient Monitor: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2025-0626 being exploited?

There is no confirmed exploitation: CVE-2025-0626 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.95% chance of exploitation in the next 30 days (as of 2026-11-26).

### How serious is CVE-2025-0626?

High: CVSS 7.7 (v4.0, scored by CNA). Remote, no login needed. A user has to take an action, such as opening a link, for the attack to work.

### Which versions are affected by CVE-2025-0626?

Contec Health CMS8000 Patient Monitor All versions.

### Is there a fix for CVE-2025-0626?

No fixed version is listed in the sources yet. Vendor workaround: Per FDA recommendation, CISA recommends users remove any Contec CMS8000 devices from their networks.  If asset owners cannot remove the devices from their networks, users should block 202.114.4.0/24 from their networks, or block 202.114.4.119 and 202.114.4.120.  Please note that this device may be re-labeled and sold by resellers. For a list of known re-labeled devices, please refer to FDA's  safety communication https://www.fda.gov/medical-devices/safety-communications/cybersecurity-vulnerabilities-certain-patient-monitors-contec-and-epsimed-fda-safety-communication .

### How do I check if I'm affected by CVE-2025-0626?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- other: <https://www.cisa.gov/news-events/ics-medical-advisories/icsma-25-030-01>
- other: <https://www.fda.gov/medical-devices/safety-communications/cybersecurity-vulnerabilities-certain-patient-monitors-contec-and-epsimed-fda-safety-communication>
- other: <https://www.cisa.gov/resources-tools/resources/contec-cms8000-contains-backdoor>
- other: <https://www.bleepingcomputer.com/news/security/backdoor-found-in-two-healthcare-patient-monitors-linked-to-ip-in-china/>