# CVE-2025-0591: Out-of-bounds Read vulnerability in CX-Programmer

> Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

- **Severity:** HIGH 7.8
- **CVSS:** 7.8 (v3.1, CNA) `CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H`
- **CVSS metrics:** Attack vector: Local; Attack complexity: Low; Privileges required: None; User interaction: Required; Scope: Unchanged; Confidentiality impact: High; Integrity impact: High; Availability impact: High
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** None known
- **Remote exploitation:** Not remotely exploitable (local or adjacent access needed)
- **EPSS:** 0.29% (percentile 14, 2026-11-26)
- **CWE:** CWE-125
- **Published:** 2025-02-16T23:58:32.165Z
- **Modified:** 2026-06-17T08:26:46.520Z

## Who should check

- Anyone running OMRON Corporation FA Integrated Tool Package CX-One Ver.9.83 or lower

## Description

Out-of-bounds Read vulnerability (CWE-125) was found in CX-Programmer. Attackers may be able to read sensitive information or cause an application crash by abusing this vulnerability.

## Affected and fixed versions

- OMRON Corporation FA Integrated Tool Package CX-One: Ver.9.83 or lower (cvelist)

## Mitigation

- Vendor workaround: OMRON recommends that customers take the following mitigation measures to minimize the risk of exploitation of these vulnerabilities.
- 
- 1. Anti-virus protection Protect any PC with access to the control system against malware and ensure installation and maintenance of up-to-date commercial grade anti-virus software protection.
- 
- 2. Security measures to prevent unauthorized access
- - Minimize connection of control systems and equipment to open networks, so that untrusted devices will be unable to access them.
- - Implement firewalls (by shutting down unused communications ports, limiting communications hosts) and isolate them from the IT network.
- - Use a virtual private network (VPN) for remote access to control systems and equipment.
- - Use strong passwords and change them frequently.
- - Install physical controls so that only authorized personnel can access control systems and equipment.
- - Scan virus to ensure safety of any USB drives or similar devices before connecting them to systems and devices.
- - Enforce multifactor authentication to all devices with remote access to control systems and equipment whenever possible.
- 
- 3. Data input and output protection Validation processing such as backup and range check to cope with unintentional modification of input/output data to control systems and devices.
- 
- 4. Data recovery Periodical data backup and maintenance to prepare for data loss.

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2025-0591. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2025-0591.md
Affected: OMRON Corporation FA Integrated Tool Package CX-One Ver.9.83 or lower
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for OMRON Corporation FA Integrated Tool Package CX-One: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2025-0591 being exploited?

There is no confirmed exploitation: CVE-2025-0591 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.29% chance of exploitation in the next 30 days (as of 2026-11-26).

### How serious is CVE-2025-0591?

High: CVSS 7.8 (v3.1, scored by CNA). Not remotely exploitable (local or adjacent access needed). A user has to take an action, such as opening a link, for the attack to work.

### Which versions are affected by CVE-2025-0591?

OMRON Corporation FA Integrated Tool Package CX-One Ver.9.83 or lower.

### Is there a fix for CVE-2025-0591?

No fixed version is listed in the sources yet. Vendor workaround: OMRON recommends that customers take the following mitigation measures to minimize the risk of exploitation of these vulnerabilities.  1. Anti-virus protection Protect any PC with access to the control system against malware and ensure installation and maintenance of up-to-date commercial grade anti-virus software protection.  2. Security measures to prevent unauthorized access - Minimize connection of control systems and equipment to open networks, so that untrusted devices will be unable to access them. - Implement firewalls (by shutting down unused communications ports, limiting communications hosts) and isolate them from the IT network. - Use a virtual private network (VPN) for remote access to control systems and equipment. - Use strong passwords and change them frequently. - Install physical controls so that only authorized personnel can access control systems and equipment. - Scan virus to ensure safety of any USB drives or similar devices before connecting them to systems and devices. - Enforce multifactor authentication to all devices with remote access to control systems and equipment whenever possible.  3. Data input and output protection Validation processing such as backup and range check to cope with unintentional modification of input/output data to control systems and devices.  4. Data recovery Periodical data backup and maintenance to prepare for data loss.

### How do I check if I'm affected by CVE-2025-0591?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- other: <https://www.fa.omron.co.jp/product/security/assets/pdf/en/OMSR-2025-003_en.pdf>
- other: <https://www.fa.omron.co.jp/product/security/assets/pdf/ja/OMSR-2025-003_ja.pdf>

## Attribution

- CVE Program: CVE® is a registered trademark of The MITRE Corporation. CVE records © 1999–2026 The MITRE Corporation. <https://www.cve.org/Legal/TermsOfUse>
- NVD: This product uses data from the NVD API but is not endorsed or certified by the NVD. <https://nvd.nist.gov/vuln/detail/CVE-2025-0591>

HTML: <https://flawdb.com/CVE-2025-0591> · JSON: <https://flawdb.com/api/v1/entries/CVE-2025-0591>