# CVE-2024-8036: Unauthorized Modifications of Firmware and Configuration

> Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

- **Severity:** MEDIUM 4.6
- **CVSS:** 4.6 (v4.0, CNA) `CVSS:4.0/AV:A/AC:H/AT:P/PR:H/UI:P/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N/S:P/AU:N/R:I/V:D/RE:H/U:Amber`
- **CVSS metrics:** Attack vector: Adjacent network; Attack complexity: High; Attack requirements: Present; Privileges required: High; User interaction: Passive; Confidentiality impact: Low; Integrity impact: High; Availability impact: High; Confidentiality impact on other systems: None; Integrity impact on other systems: None; Availability impact on other systems: None; S: P; AU: N; R: I; V: D; RE: H; U: Amber
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** None known
- **Remote exploitation:** Not remotely exploitable (local or adjacent access needed)
- **EPSS:** 0.21% (percentile 7, 2026-11-26)
- **CWE:** CWE-347
- **Published:** 2024-10-25T16:57:31.114Z
- **Modified:** 2026-06-17T08:21:44.047Z

## Who should check

- Anyone running ABB Relion Protection Relays RE\_611 IEC \>= 1.0.0, \<= 1.0.4; \>= 2.0.0, \<= 2.0.4
- Anyone running ABB Relion Protection Relays REF615 IEC \>= 1.0.0, \<= 1.2.0
- Anyone running ABB Relion Protection Relays REF615 ANSI \>= 1.0.0, \<= 1.1.0
- Anyone running ABB Relion Protection Relays REX615 PCL1
- Anyone running ABB Relion Protection Relays REX610 1.1.1; 1.2.0
- Anyone running ABB Relion Protection Relays REX640 \>= 1.0.0, \<= 1.0.8; \>= 1.1.0, \<= 1.1.6; \>= 1.2.0, \<= 1.2.3; \>= 1.3.0, \<= 1.3.4
- Anyone running ABB Substation Merging Unit SMU615 \>= 1.0.0, \<= 1.0.3
- Anyone running ABB Smart Substation Control and Protection SSC600 1.0; 1.0 FP1; 1.0 FP2; 1.0 FP3; 1.0 FP4

## Description

ABB is aware of privately reported vulnerabilities in the product versions referenced in this CVE. An attacker could exploit these vulnerabilities by sending a specially crafted firmware or configuration to the system node, causing the node to stop, become inaccessible, or allowing the attacker to take control of the node.

## Affected and fixed versions

- ABB Relion Protection Relays RE\_611 IEC: \>= 1.0.0, \<= 1.0.4; \>= 2.0.0, \<= 2.0.4 (cvelist)
- ABB Relion Protection Relays REF615 IEC: \>= 1.0.0, \<= 1.2.0 (cvelist)
- ABB Relion Protection Relays REF615 ANSI: \>= 1.0.0, \<= 1.1.0 (cvelist)
- ABB Relion Protection Relays REX615: PCL1 (cvelist)
- ABB Relion Protection Relays REX610: 1.1.1; 1.2.0 (cvelist)
- ABB Relion Protection Relays REX640: \>= 1.0.0, \<= 1.0.8; \>= 1.1.0, \<= 1.1.6; \>= 1.2.0, \<= 1.2.3; \>= 1.3.0, \<= 1.3.4 (cvelist)
- ABB Substation Merging Unit SMU615: \>= 1.0.0, \<= 1.0.3 (cvelist)
- ABB Smart Substation Control and Protection SSC600: 1.0; 1.0 FP1; 1.0 FP2; 1.0 FP3; 1.0 FP4 (cvelist)
- ABB Relion Protection Relays REF615R ANSI: \>= 4.0.0, \<= 4.1.2 (cvelist)
- ABB Relion Protection Relays RED615 IEC: \>= 1.0.0, \<= 1.1.5 (cvelist)
- ABB Relion Protection Relays 615 series IEC: \>= 2.0.0, \<= 2.0.9; \>= 3.0.0, \<= 3.0.10; \>= 4.0.0, \<= 4.0.8; \>= 4.1.9, \<= 4.1.10; \>= 5.0.0, \<= 5.0.17; \>= 5.1.0, \<= 5.1.24 (cvelist)
- ABB Relion Protection Relays 615 series CN: \>= 2.0.0, \<= 2.0.9; \>= 3.0.0, \<= 3..0.7; \>= 3.1.0, \<= 3.1.10; \>= 4.1.0, \<= 4.1.9; \>= 5.1.0, \<= 5.1.4 (cvelist)
- ABB Relion Protection Relays 615 series ANSI: \>= 2.0.0, \<= 2.0.9; \>= 4.0.0, \<= 4.0.5; \>= 4.1.0, \<= 4.1.1; \>= 4.2.0, \<= 4.2.3; \>= 5.1.0, \<= 5.1.3 (cvelist)
- ABB Relion Protection Relays RER615: \>= 1.0.0, \<= 1.1.4; \>= 2.0.0, \<= 2.0.9 (cvelist)
- ABB Relion Protection Relays REC615: \>= 1.0.0, \<= 1.1.4; \>= 2.0.0, \<= 2.0.9 (cvelist)
- ABB RBX615: \>= 1.0.0, \<= 2.0.0 (cvelist)
- ABB RER620 ANSI: \>= 1.0.0, \<= 1.3 (cvelist)
- ABB 620 Series IEC/CN: \>= 2.0.0, \<= 2.0.13; \>= 2.1.0, \<= 2.1.16 (cvelist)
- ABB RE\_630: \>= 1.1.0, \<= 1.1.0 C5; \>= 1.2.0, \<= 1.2.0 B8; \>= 1.3.0, \<= 1.3.0 B1 (cvelist)
- ABB RIO600: \>= 1.0.0, \<= 1.8.8 (cvelist)
- ABB COM600: 3.3; 3.4; 3.5; 4.0; 4.1; 5.0; 5.1 (cvelist)
- ABB SPA ZC-400: Exx; Mxx; Sxx; xMx; Exxx; Mxxx; Sxxx; xMxx; xxxC (cvelist)
- ABB COM600F ANSI: 4.1; 5.0 (cvelist)
- ABB SPA ZC-402: Exxx; Mxxx; Sxxx; xMxx; xxxC (cvelist)
- ABB REF542plus: R1.0; R1.1; R2.0; R2.5; R2.5 ATEX; R2.5 SP3; R2.6; R3.0; R3.0 SP1; R3.0 SP3 (cvelist)
- ABB SUE 3000: 2.6 V4F07x; 3.0FP1 V4F11x; V4D02x; V4E0xx (cvelist)
- ABB ARG600/ARP600/ARR600/ARC600 single SIM: \>= 3.x.x, \<= 3.4.13 (cvelist)
- ABB ARG600/ARP600 dual SIM: \>= 2.x.x, \<= 3.4.13 (cvelist)
- ABB ARM600: \>= 4.x.x, \<= 5.0.3 (cvelist)
- ABB REC601/RER601: \>= 1.1, \<= 1.2 (cvelist)
- ABB REC603/RER603: \>= 1.1, \<= 1.2 (cvelist)

## Mitigation

- Vendor workaround: Please follow the guidelines in the following Product Advisory Note to improve the system security:
- 
- Guidelines to Prevent Unauthorized Modifications of Firmware and Configuration, ABB Digital
- Substation Products ( https://search.abb.com/library/Download.aspx?DocumentID=2NGA002288&LanguageCode=en&DocumentP... https://search.abb.com/library/Download.aspx )

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2024-8036. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2024-8036.md
Affected: ABB Relion Protection Relays RE_611 IEC >= 1.0.0, <= 1.0.4; >= 2.0.0, <= 2.0.4; ABB Relion Protection Relays REF615 IEC >= 1.0.0, <= 1.2.0; ABB Relion Protection Relays REF615 ANSI >= 1.0.0, <= 1.1.0; ABB Relion Protection Relays REX615 PCL1; ABB Relion Protection Relays REX610 1.1.1; 1.2.0; ABB Re…
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for ABB Relion Protection Relays RE_611 IEC, ABB Relion Protection Relays REF615 IEC, ABB Relion Protection Relays REF615 ANSI, ABB Relion Protection Relays REX615, ABB Relion Protection Relays REX610, ABB Relion Protection Relays REX640: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2024-8036 being exploited?

There is no confirmed exploitation: CVE-2024-8036 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.21% chance of exploitation in the next 30 days (as of 2026-11-26).

### How serious is CVE-2024-8036?

Medium: CVSS 4.6 (v4.0, scored by CNA). Not remotely exploitable (local or adjacent access needed). A user has to take an action, such as opening a link, for the attack to work. The attack needs conditions outside the attacker's control, which makes it harder.

### Which versions are affected by CVE-2024-8036?

ABB Relion Protection Relays RE\_611 IEC \>= 1.0.0, \<= 1.0.4; \>= 2.0.0, \<= 2.0.4; ABB Relion Protection Relays REF615 IEC \>= 1.0.0, \<= 1.2.0; ABB Relion Protection Relays REF615 ANSI \>= 1.0.0, \<= 1.1.0; ABB Relion Protection Relays REX615 PCL1; ABB Relion Protection Relays REX610 1.1.1; 1.2.0; ABB Relion Protection Relays REX640 \>= 1.0.0, \<= 1.0.8; \>= 1.1.0, \<= 1.1.6; \>= 1.2.0, \<= 1.2.3; \>= 1.3.0, \<= 1.3.4; ABB Substation Merging Unit SMU615 \>= 1.0.0, \<= 1.0.3; ABB Smart Substation Control and Protection SSC600 1.0; 1.0 FP1; 1.0 FP2; 1.0 FP3; 1.0 FP4; ABB Relion Protection Relays REF615R ANSI \>= 4.0.0, \<= 4.1.2; ABB Relion Protection Relays RED615 IEC \>= 1.0.0, \<= 1.1.5; ABB Relion Protection Relays 615 series IEC \>= 2.0.0, \<= 2.0.9; \>= 3.0.0, \<= 3.0.10; \>= 4.0.0, \<= 4.0.8; \>= 4.1.9, \<= 4.1.10; \>= 5.0.0, \<= 5.0.17; \>= 5.1.0, \<= 5.1.24; ABB Relion Protection Relays 615 series CN \>= 2.0.0, \<= 2.0.9; \>= 3.0.0, \<= 3..0.7; \>= 3.1.0, \<= 3.1.10; \>= 4.1.0, \<= 4.1.9; \>= 5.1.0, \<= 5.1.4; ABB Relion Protection Relays 615 series ANSI \>= 2.0.0, \<= 2.0.9; \>= 4.0.0, \<= 4.0.5; \>= 4.1.0, \<= 4.1.1; \>= 4.2.0, \<= 4.2.3; \>= 5.1.0, \<= 5.1.3; ABB Relion Protection Relays RER615 \>= 1.0.0, \<= 1.1.4; \>= 2.0.0, \<= 2.0.9; ABB Relion Protection Relays REC615 \>= 1.0.0, \<= 1.1.4; \>= 2.0.0, \<= 2.0.9; ABB RBX615 \>= 1.0.0, \<= 2.0.0; ABB RER620 ANSI \>= 1.0.0, \<= 1.3; ABB 620 Series IEC/CN \>= 2.0.0, \<= 2.0.13; \>= 2.1.0, \<= 2.1.16; ABB RE\_630 \>= 1.1.0, \<= 1.1.0 C5; \>= 1.2.0, \<= 1.2.0 B8; \>= 1.3.0, \<= 1.3.0 B1; ABB RIO600 \>= 1.0.0, \<= 1.8.8; ABB COM600 3.3; 3.4; 3.5; 4.0; 4.1; 5.0; 5.1; ABB SPA ZC-400 Exx; Mxx; Sxx; xMx; Exxx; Mxxx; Sxxx; xMxx; xxxC; ABB COM600F ANSI 4.1; 5.0; ABB SPA ZC-402 Exxx; Mxxx; Sxxx; xMxx; xxxC; ABB REF542plus R1.0; R1.1; R2.0; R2.5; R2.5 ATEX; R2.5 SP3; R2.6; R3.0; R3.0 SP1; R3.0 SP3; ABB SUE 3000 2.6 V4F07x; 3.0FP1 V4F11x; V4D02x; V4E0xx; ABB ARG600/ARP600/ARR600/ARC600 single SIM \>= 3.x.x, \<= 3.4.13; ABB ARG600/ARP600 dual SIM \>= 2.x.x, \<= 3.4.13; ABB ARM600 \>= 4.x.x, \<= 5.0.3; ABB REC601/RER601 \>= 1.1, \<= 1.2; ABB REC603/RER603 \>= 1.1, \<= 1.2.

### Is there a fix for CVE-2024-8036?

No fixed version is listed in the sources yet. Vendor workaround: Please follow the guidelines in the following Product Advisory Note to improve the system security:  Guidelines to Prevent Unauthorized Modifications of Firmware and Configuration, ABB Digital Substation Products ( https://search.abb.com/library/Download.aspx?DocumentID=2NGA002288&LanguageCode=en&DocumentP... https://search.abb.com/library/Download.aspx )

### How do I check if I'm affected by CVE-2024-8036?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- other: <https://search.abb.com/library/Download.aspx?DocumentID=2NGA001911&LanguageCode=en&DocumentPartId=&Action=Launch>

## Attribution

- CVE Program: CVE® is a registered trademark of The MITRE Corporation. CVE records © 1999–2026 The MITRE Corporation. <https://www.cve.org/Legal/TermsOfUse>
- NVD: This product uses data from the NVD API but is not endorsed or certified by the NVD. <https://nvd.nist.gov/vuln/detail/CVE-2024-8036>

HTML: <https://flawdb.com/CVE-2024-8036> · JSON: <https://flawdb.com/api/v1/entries/CVE-2024-8036>
