CVE-2024-7585
Tenda i22 apPortalAuth formApPortalWebAuth buffer overflow
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Tenda i22 1.0.0.3(4687)
Vulnerability facts
- Affected
- Tenda i22 1.0.0.3(4687)
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- Yes: see the exploit references below
- Remote exploitation
- Remote, login needed
- CVSS
- 8.7 (v4.0, CNA)CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:NOpen in CVSS calculator
Show all 11 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Attack requirements: None
- Privileges required: Low
- User interaction: None
- Confidentiality impact: High
- Integrity impact: High
- Availability impact: High
- Confidentiality impact on other systems: None
- Integrity impact on other systems: None
- Availability impact on other systems: None
- EPSS
- 2.14% chance of exploitation in 30 days (percentile 83, 2026-11-26)
- CWE
- CWE-120
- Modified
Description
A vulnerability has been found in Tenda i22 1.0.0.3(4687) and classified as critical. Affected by this vulnerability is the function formApPortalWebAuth of the file /goform/apPortalAuth. The manipulation of the argument webUserName/webUserPassword leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Tenda i22 | 1.0.0.3(4687) | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2024-7585. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2024-7585.md Affected: Tenda i22 1.0.0.3(4687) Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Tenda i22: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
Articles
FAQ
Is CVE-2024-7585 being exploited?
There is no confirmed exploitation: CVE-2024-7585 is not in the CISA Known Exploited Vulnerabilities catalog. Public exploit code or a proof of concept is available. EPSS estimates a 2.14% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2024-7585?
High: CVSS 8.7 (v4.0, scored by CNA). Remote, login needed.
Which versions are affected by CVE-2024-7585?
Tenda i22 1.0.0.3(4687).
Is there a fix for CVE-2024-7585?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2024-7585?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.