# CVE-2024-6796: Vulnerability in Baxter Connex Health Portal

> Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

- **Severity:** HIGH 8.2
- **CVSS:** 8.2 (v3.1, CNA) `CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:N`
- **CVSS metrics:** Attack vector: Network; Attack complexity: Low; Privileges required: None; User interaction: None; Scope: Unchanged; Confidentiality impact: Low; Integrity impact: High; Availability impact: None
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** None known
- **Remote exploitation:** Remote, no login needed
- **EPSS:** 0.63% (percentile 45, 2026-11-26)
- **CWE:** CWE-284
- **Published:** 2024-09-09T19:28:30.647Z
- **Modified:** 2026-06-17T08:18:43.907Z

## Who should check

- Anyone running Baxter Connex Health Portal \< 8/30/2024

## Description

In Baxter Connex health portal released before 8/30/2024, an improper access control vulnerability has been found that could allow an unauthenticated attacker to gain unauthorized access to Connex portal's database and/or modify content.

## Affected and fixed versions

- Baxter Connex Health Portal: \< 8/30/2024 (cvelist)

## Mitigation

- Upgrade Connex Health Portal to 8/30/2024 or later.

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2024-6796. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2024-6796.md
Affected: Baxter Connex Health Portal < 8/30/2024
Fixed in: Baxter Connex Health Portal 8/30/2024

Steps:
1. Search this machine and project for Baxter Connex Health Portal: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2024-6796 being exploited?

There is no confirmed exploitation: CVE-2024-6796 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.63% chance of exploitation in the next 30 days (as of 2026-11-26).

### How serious is CVE-2024-6796?

High: CVSS 8.2 (v3.1, scored by CNA). Remote, no login needed.

### Which versions are affected by CVE-2024-6796?

Baxter Connex Health Portal \< 8/30/2024.

### Is there a fix for CVE-2024-6796?

Yes. Fixed in Baxter Connex Health Portal 8/30/2024. Upgrade Connex Health Portal to 8/30/2024 or later.

### How do I check if I'm affected by CVE-2024-6796?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- other: <https://www.cisa.gov/news-events/ics-medical-advisories/icsma-24-249-01>

## Attribution

- CVE Program: CVE® is a registered trademark of The MITRE Corporation. CVE records © 1999–2026 The MITRE Corporation. <https://www.cve.org/Legal/TermsOfUse>
- NVD: This product uses data from the NVD API but is not endorsed or certified by the NVD. <https://nvd.nist.gov/vuln/detail/CVE-2024-6796>

HTML: <https://flawdb.com/CVE-2024-6796> · JSON: <https://flawdb.com/api/v1/entries/CVE-2024-6796>
