Skip to content
FlawDB
Sign in
Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

CVE-2024-6795

CRITICAL 10.0EPSS 59%

Vulnerability in Baxter Connex Health Portal

Mitigation

  • Upgrade Connex Health Portal to 8/30/2024 or later.

Who should check

  • Anyone running Baxter Connex Health Portal < 8/30/2024

Vulnerability facts

Affected
Baxter Connex Health Portal < 8/30/2024
Fixed in
Baxter Connex Health Portal 8/30/2024
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Remote, no login needed
CVSS
10.0 (v3.1, CNA)CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
  • Attack vector: Network
  • Attack complexity: Low
  • Privileges required: None
  • User interaction: None
  • Scope: Changed (impact reaches other components)
  • Confidentiality impact: High
  • Integrity impact: High
  • Availability impact: High
EPSS
0.92% chance of exploitation in 30 days (percentile 59, 2026-11-26)
CWE
CWE-89
Published
Modified

Description

In Connex health portal released before8/30/2024, SQL injection vulnerabilities were found that could have allowed an unauthenticated attacker to gain unauthorized access to Connex portal's database.  An attacker could have submitted a crafted payload to Connex portal that could have resulted in modification and disclosure of database content and/or perform administrative operations including shutting down the database.

Affected and fixed versions

Package / productAffectedFixedSource
Baxter Connex Health Portal< 8/30/2024—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2024-6795. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2024-6795.md
Affected: Baxter Connex Health Portal < 8/30/2024
Fixed in: Baxter Connex Health Portal 8/30/2024

Steps:
1. Search this machine and project for Baxter Connex Health Portal: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2024-6795 being exploited?

There is no confirmed exploitation: CVE-2024-6795 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.92% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2024-6795?

Critical: CVSS 10.0 (v3.1, scored by CNA). Remote, no login needed.

Which versions are affected by CVE-2024-6795?

Baxter Connex Health Portal < 8/30/2024.

Is there a fix for CVE-2024-6795?

Yes. Fixed in Baxter Connex Health Portal 8/30/2024. Upgrade Connex Health Portal to 8/30/2024 or later.

How do I check if I'm affected by CVE-2024-6795?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors