CVE-2024-56181
A vulnerability has been identified in SIMATIC Field PG M5 (All versions), SIMATIC IPC BX-21A (All versions < V31.01.07…
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Siemens SIMATIC Field PG M5 < *
- Anyone running Siemens SIMATIC IPC BX-21A < V31.01.07
- Anyone running Siemens SIMATIC IPC BX-32A < V29.01.07
- Anyone running Siemens SIMATIC IPC BX-39A < V29.01.07
- Anyone running Siemens SIMATIC IPC BX-59A < V32.01.04
- Anyone running Siemens SIMATIC IPC PX-32A < V29.01.07
- Anyone running Siemens SIMATIC IPC PX-39A < V29.01.07
- Anyone running Siemens SIMATIC IPC PX-39A PRO < V29.01.07
Vulnerability facts
- Affected
- Siemens SIMATIC Field PG M5 < *; Siemens SIMATIC IPC BX-21A < V31.01.07; Siemens SIMATIC IPC BX-32A < V29.01.07; Siemens SIMATIC IPC BX-39A < V29.01.07; Siemens SIMATIC IPC BX-59A < V32.01.04; Siemens SIMATIC IPC PX-32A < V29.01.07; Siemens SIMATIC IPC PX-39A < V29.01.07; Siemens SIMATIC IPC PX-39A PRO < V29.01.07; Siemens SIMATIC IPC RC-543A < V36.01.03; Siemens SIMATIC IPC RC-543B < V35.01.12; Siemens SIMATIC IPC RW-543A < V1.1.4; Siemens SIMATIC IPC RW-543B < V35.02.10; Siemens SIMATIC IPC127E < V27.01.11; Siemens SIMATIC IPC227E < *; Siemens SIMATIC IPC227G < V28.01.14; Siemens SIMATIC IPC277E < *; Siemens SIMATIC IPC277G < V28.01.14; Siemens SIMATIC IPC277G PRO < V28.01.14; Siemens SIMATIC IPC3000 SMART V3 < *; Siemens SIMATIC IPC327G < V28.01.14; Siemens SIMATIC IPC347G < *; Siemens SIMATIC IPC377G < V28.01.14; Siemens SIMATIC IPC427E < V21.01.21; Siemens SIMATIC IPC477E < V21.01.21; Siemens SIMATIC IPC477E PRO < V21.01.21; Siemens SIMATIC IPC527G < *; Siemens SIMATIC IPC627E < V25.02.15; Siemens SIMATIC IPC647E < V25.02.15; Siemens SIMATIC IPC677E < V25.02.15; Siemens SIMATIC IPC847E < V25.02.15; Siemens SIMATIC ITP1000 < *
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Not remotely exploitable (local or adjacent access needed)
- CVSS
- 8.4 (v4.0, CNA)CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:N/VI:H/VA:H/SC:H/SI:H/SA:HOpen in CVSS calculator
Show all 11 CVSS metrics
- Attack vector: Local
- Attack complexity: Low
- Attack requirements: None
- Privileges required: High
- User interaction: None
- Confidentiality impact: None
- Integrity impact: High
- Availability impact: High
- Confidentiality impact on other systems: High
- Integrity impact on other systems: High
- Availability impact on other systems: High
- EPSS
- 0.27% chance of exploitation in 30 days (percentile 12, 2026-11-26)
- CWE
- CWE-693
- Modified
Description
A vulnerability has been identified in SIMATIC Field PG M5 (All versions), SIMATIC IPC BX-21A (All versions < V31.01.07), SIMATIC IPC BX-32A (All versions < V29.01.07), SIMATIC IPC BX-39A (All versions < V29.01.07), SIMATIC IPC BX-59A (All versions < V32.01.04), SIMATIC IPC PX-32A (All versions < V29.01.07), SIMATIC IPC PX-39A (All versions < V29.01.07), SIMATIC IPC PX-39A PRO (All versions < V29.01.07), SIMATIC IPC RC-543A (All versions < V36.01.03), SIMATIC IPC RC-543B (All versions < V35.01.12), SIMATIC IPC RW-543A (All versions < V1.1.4), SIMATIC IPC RW-543B (All versions < V35.02.10), SIMATIC IPC127E (All versions < V27.01.11), SIMATIC IPC227E (All versions), SIMATIC IPC227G (All versions < V28.01.14), SIMATIC IPC277E (All versions), SIMATIC IPC277G (All versions < V28.01.14), SIMATIC IPC277G PRO (All versions < V28.01.14), SIMATIC IPC3000 SMART V3 (All versions), SIMATIC IPC327G (All versions < V28.01.14), SIMATIC IPC347G (All versions), SIMATIC IPC377G (All versions < V28.01.14), SIMATIC IPC427E (All versions < V21.01.21), SIMATIC IPC477E (All versions < V21.01.21), SIMATIC IPC477E PRO (All versions < V21.01.21), SIMATIC IPC527G (All versions), SIMATIC IPC627E (All versions < V25.02.15), SIMATIC IPC647E (All versions < V25.02.15), SIMATIC IPC677E (All versions < V25.02.15), SIMATIC IPC847E (All versions < V25.02.15), SIMATIC ITP1000 (All versions). The affected devices have insufficient protection mechanism for the EFI(Extensible Firmware Interface) variables stored on the device. This could allow an authenticated attacker to alter the secure boot configuration without proper authorization by directly communicate with the flash controller.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Siemens SIMATIC Field PG M5 | < * | — | cvelist |
| Siemens SIMATIC IPC BX-21A | < V31.01.07 | — | cvelist |
| Siemens SIMATIC IPC BX-32A | < V29.01.07 | — | cvelist |
| Siemens SIMATIC IPC BX-39A | < V29.01.07 | — | cvelist |
| Siemens SIMATIC IPC BX-59A | < V32.01.04 | — | cvelist |
| Siemens SIMATIC IPC PX-32A | < V29.01.07 | — | cvelist |
| Siemens SIMATIC IPC PX-39A | < V29.01.07 | — | cvelist |
| Siemens SIMATIC IPC PX-39A PRO | < V29.01.07 | — | cvelist |
| Siemens SIMATIC IPC RC-543A | < V36.01.03 | — | cvelist |
| Siemens SIMATIC IPC RC-543B | < V35.01.12 | — | cvelist |
| Siemens SIMATIC IPC RW-543A | < V1.1.4 | — | cvelist |
| Siemens SIMATIC IPC RW-543B | < V35.02.10 | — | cvelist |
| Siemens SIMATIC IPC127E | < V27.01.11 | — | cvelist |
| Siemens SIMATIC IPC227E | < * | — | cvelist |
| Siemens SIMATIC IPC227G | < V28.01.14 | — | cvelist |
| Siemens SIMATIC IPC277E | < * | — | cvelist |
| Siemens SIMATIC IPC277G | < V28.01.14 | — | cvelist |
| Siemens SIMATIC IPC277G PRO | < V28.01.14 | — | cvelist |
| Siemens SIMATIC IPC3000 SMART V3 | < * | — | cvelist |
| Siemens SIMATIC IPC327G | < V28.01.14 | — | cvelist |
| Siemens SIMATIC IPC347G | < * | — | cvelist |
| Siemens SIMATIC IPC377G | < V28.01.14 | — | cvelist |
| Siemens SIMATIC IPC427E | < V21.01.21 | — | cvelist |
| Siemens SIMATIC IPC477E | < V21.01.21 | — | cvelist |
| Siemens SIMATIC IPC477E PRO | < V21.01.21 | — | cvelist |
| Siemens SIMATIC IPC527G | < * | — | cvelist |
| Siemens SIMATIC IPC627E | < V25.02.15 | — | cvelist |
| Siemens SIMATIC IPC647E | < V25.02.15 | — | cvelist |
| Siemens SIMATIC IPC677E | < V25.02.15 | — | cvelist |
| Siemens SIMATIC IPC847E | < V25.02.15 | — | cvelist |
| Siemens SIMATIC ITP1000 | < * | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2024-56181. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2024-56181.md Affected: Siemens SIMATIC Field PG M5 < *; Siemens SIMATIC IPC BX-21A < V31.01.07; Siemens SIMATIC IPC BX-32A < V29.01.07; Siemens SIMATIC IPC BX-39A < V29.01.07; Siemens SIMATIC IPC BX-59A < V32.01.04; Siemens SIMATIC IPC PX-32A < V29.01.07; Siemens SIMATIC IPC PX-39A < V29.01.07; Siemens SIMATIC IPC PX-39A… Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Siemens SIMATIC Field PG M5, Siemens SIMATIC IPC BX-21A, Siemens SIMATIC IPC BX-32A, Siemens SIMATIC IPC BX-39A, Siemens SIMATIC IPC BX-59A, Siemens SIMATIC IPC PX-32A: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2024-56181 being exploited?
There is no confirmed exploitation: CVE-2024-56181 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.27% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2024-56181?
High: CVSS 8.4 (v4.0, scored by CNA). Not remotely exploitable (local or adjacent access needed).
Which versions are affected by CVE-2024-56181?
Siemens SIMATIC Field PG M5 < *; Siemens SIMATIC IPC BX-21A < V31.01.07; Siemens SIMATIC IPC BX-32A < V29.01.07; Siemens SIMATIC IPC BX-39A < V29.01.07; Siemens SIMATIC IPC BX-59A < V32.01.04; Siemens SIMATIC IPC PX-32A < V29.01.07; Siemens SIMATIC IPC PX-39A < V29.01.07; Siemens SIMATIC IPC PX-39A PRO < V29.01.07; Siemens SIMATIC IPC RC-543A < V36.01.03; Siemens SIMATIC IPC RC-543B < V35.01.12; Siemens SIMATIC IPC RW-543A < V1.1.4; Siemens SIMATIC IPC RW-543B < V35.02.10; Siemens SIMATIC IPC127E < V27.01.11; Siemens SIMATIC IPC227E < *; Siemens SIMATIC IPC227G < V28.01.14; Siemens SIMATIC IPC277E < *; Siemens SIMATIC IPC277G < V28.01.14; Siemens SIMATIC IPC277G PRO < V28.01.14; Siemens SIMATIC IPC3000 SMART V3 < *; Siemens SIMATIC IPC327G < V28.01.14; Siemens SIMATIC IPC347G < *; Siemens SIMATIC IPC377G < V28.01.14; Siemens SIMATIC IPC427E < V21.01.21; Siemens SIMATIC IPC477E < V21.01.21; Siemens SIMATIC IPC477E PRO < V21.01.21; Siemens SIMATIC IPC527G < *; Siemens SIMATIC IPC627E < V25.02.15; Siemens SIMATIC IPC647E < V25.02.15; Siemens SIMATIC IPC677E < V25.02.15; Siemens SIMATIC IPC847E < V25.02.15; Siemens SIMATIC ITP1000 < *.
Is there a fix for CVE-2024-56181?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2024-56181?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.