# CVE-2024-48974: Life2000 Ventilator does not perform proper file integrity checks when adopting firmware updates

> Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

- **Severity:** CRITICAL 9.3
- **CVSS:** 9.3 (v3.1, CNA) `CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H`
- **CVSS metrics:** Attack vector: Local; Attack complexity: Low; Privileges required: None; User interaction: None; Scope: Changed (impact reaches other components); Confidentiality impact: High; Integrity impact: High; Availability impact: High
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** None known
- **Remote exploitation:** Not remotely exploitable (local or adjacent access needed)
- **EPSS:** 0.19% (percentile 5, 2026-11-26)
- **CWE:** CWE-494
- **Published:** 2024-11-14T21:27:10.284Z
- **Modified:** 2026-06-17T07:59:08.733Z

## Who should check

- Anyone running Baxter Life2000 Ventilation System 06.08.00.00 and prior

## Description

The ventilator does not perform proper file integrity checks when adopting firmware updates. This makes it possible for an attacker to force unauthorized changes to the device's configuration settings and/or compromise device functionality by pushing a compromised/illegitimate firmware file. This could disrupt the function of the device and/or cause unauthorized information disclosure.

## Affected and fixed versions

- Baxter Life2000 Ventilation System: 06.08.00.00 and prior (cvelist)

## Mitigation

- No fix listed yet: follow the vendor advisory.

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2024-48974. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2024-48974.md
Affected: Baxter Life2000 Ventilation System 06.08.00.00 and prior
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Baxter Life2000 Ventilation System: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2024-48974 being exploited?

There is no confirmed exploitation: CVE-2024-48974 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.19% chance of exploitation in the next 30 days (as of 2026-11-26).

### How serious is CVE-2024-48974?

Critical: CVSS 9.3 (v3.1, scored by CNA). Not remotely exploitable (local or adjacent access needed).

### Which versions are affected by CVE-2024-48974?

Baxter Life2000 Ventilation System 06.08.00.00 and prior.

### Is there a fix for CVE-2024-48974?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

### How do I check if I'm affected by CVE-2024-48974?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- other: <https://www.cisa.gov/news-events/ics-medical-advisories/icsma-24-319-01>

## Attribution

- CVE Program: CVE® is a registered trademark of The MITRE Corporation. CVE records © 1999–2026 The MITRE Corporation. <https://www.cve.org/Legal/TermsOfUse>
- NVD: This product uses data from the NVD API but is not endorsed or certified by the NVD. <https://nvd.nist.gov/vuln/detail/CVE-2024-48974>

HTML: <https://flawdb.com/CVE-2024-48974> · JSON: <https://flawdb.com/api/v1/entries/CVE-2024-48974>