# CVE-2024-48966: Life2000 service tools for test and calibration do not support user authentication

> Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

- **Severity:** CRITICAL 10.0
- **CVSS:** 10.0 (v3.1, CNA) `CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H`
- **CVSS metrics:** Attack vector: Network; Attack complexity: Low; Privileges required: None; User interaction: None; Scope: Changed (impact reaches other components); Confidentiality impact: High; Integrity impact: High; Availability impact: High
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** None known
- **Remote exploitation:** Remote, no login needed
- **EPSS:** 0.99% (percentile 61, 2026-11-26)
- **CWE:** CWE-306
- **Published:** 2024-11-14T21:38:11.113Z
- **Modified:** 2026-06-17T07:59:08.223Z

## Who should check

- Anyone running Baxter Life2000 Ventilation System 06.08.00.00 and prior

## Description

The software tools used by service personnel to test & calibrate the ventilator do not support user authentication. An attacker with access to the Service PC where the tools are installed could obtain diagnostic information through the test tool or manipulate the ventilator's settings and embedded software via the calibration tool, without having to authenticate to either tool. This could result in unauthorized disclosure of information and/or have unintended impacts on device settings and performance.

## Affected and fixed versions

- Baxter Life2000 Ventilation System: 06.08.00.00 and prior (cvelist)

## Mitigation

- No fix listed yet: follow the vendor advisory.

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2024-48966. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2024-48966.md
Affected: Baxter Life2000 Ventilation System 06.08.00.00 and prior
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Baxter Life2000 Ventilation System: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2024-48966 being exploited?

There is no confirmed exploitation: CVE-2024-48966 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.99% chance of exploitation in the next 30 days (as of 2026-11-26).

### How serious is CVE-2024-48966?

Critical: CVSS 10.0 (v3.1, scored by CNA). Remote, no login needed.

### Which versions are affected by CVE-2024-48966?

Baxter Life2000 Ventilation System 06.08.00.00 and prior.

### Is there a fix for CVE-2024-48966?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

### How do I check if I'm affected by CVE-2024-48966?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- other: <https://www.cisa.gov/news-events/ics-medical-advisories/icsma-24-319-01>

## Attribution

- CVE Program: CVE® is a registered trademark of The MITRE Corporation. CVE records © 1999–2026 The MITRE Corporation. <https://www.cve.org/Legal/TermsOfUse>
- NVD: This product uses data from the NVD API but is not endorsed or certified by the NVD. <https://nvd.nist.gov/vuln/detail/CVE-2024-48966>

HTML: <https://flawdb.com/CVE-2024-48966> · JSON: <https://flawdb.com/api/v1/entries/CVE-2024-48966>