CVE-2024-47945
Predictable Session ID
Mitigation
- Upgrade IoT Interface & CMC III Processing Unit to 6.21.00.2 or later.
Who should check
- Anyone running RITTAL GmbH & Co. KG IoT Interface & CMC III Processing Unit <6.21.00.2
Vulnerability facts
- Affected
- RITTAL GmbH & Co. KG IoT Interface & CMC III Processing Unit <6.21.00.2
- Fixed in
- RITTAL GmbH & Co. KG IoT Interface & CMC III Processing Unit 6.21.00.2
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- Yes: see the exploit references below
- Remote exploitation
- Remote, no login needed
- CVSS
- 9.1 (v3.1, CNA)CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:NOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Privileges required: None
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: High
- Integrity impact: High
- Availability impact: None
- EPSS
- 1.12% chance of exploitation in 30 days (percentile 66, 2026-11-26)
- CWE
- CWE-340
- Modified
Description
The devices are vulnerable to session hijacking due to insufficient entropy in its session ID generation algorithm. The session IDs are predictable, with only 32,768 possible values per user, which allows attackers to pre-generate valid session IDs, leading to unauthorized access to user sessions. This is not only due to the use of an (insecure) rand() function call but also because of missing initialization via srand(). As a result only the PIDs are effectively used as seed.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| RITTAL GmbH & Co. KG IoT Interface & CMC III Processing Unit | <6.21.00.2 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2024-47945. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2024-47945.md Affected: RITTAL GmbH & Co. KG IoT Interface & CMC III Processing Unit <6.21.00.2 Fixed in: RITTAL GmbH & Co. KG IoT Interface & CMC III Processing Unit 6.21.00.2 Steps: 1. Search this machine and project for RITTAL GmbH & Co. KG IoT Interface & CMC III Processing Unit: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
Exploits and PoCs
FAQ
Is CVE-2024-47945 being exploited?
There is no confirmed exploitation: CVE-2024-47945 is not in the CISA Known Exploited Vulnerabilities catalog. Public exploit code or a proof of concept is available. EPSS estimates a 1.12% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2024-47945?
Critical: CVSS 9.1 (v3.1, scored by CNA). Remote, no login needed.
Which versions are affected by CVE-2024-47945?
RITTAL GmbH & Co. KG IoT Interface & CMC III Processing Unit <6.21.00.2.
Is there a fix for CVE-2024-47945?
Yes. Fixed in RITTAL GmbH & Co. KG IoT Interface & CMC III Processing Unit 6.21.00.2. Upgrade IoT Interface & CMC III Processing Unit to 6.21.00.2 or later.
How do I check if I'm affected by CVE-2024-47945?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.