Skip to content
FlawDB
Sign in
Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

CVE-2024-47944

MEDIUM 6.8EPSS 39%

Missing Protection Mechanism for Alternate Hardware Interface

Mitigation

  • Upgrade IoT Interface & CMC III Processing Unit to 6.21.00.2 or later.

Who should check

  • Anyone running RITTAL GmbH & Co. KG IoT Interface & CMC III Processing Unit <6.21.00.2

Vulnerability facts

Affected
RITTAL GmbH & Co. KG IoT Interface & CMC III Processing Unit <6.21.00.2
Fixed in
RITTAL GmbH & Co. KG IoT Interface & CMC III Processing Unit 6.21.00.2
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Not remotely exploitable (local or adjacent access needed)
CVSS
6.8 (v3.1, CNA)CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
  • Attack vector: Physical
  • Attack complexity: Low
  • Privileges required: None
  • User interaction: None
  • Scope: Unchanged
  • Confidentiality impact: High
  • Integrity impact: High
  • Availability impact: High
EPSS
0.54% chance of exploitation in 30 days (percentile 39, 2026-11-26)
CWE
CWE-1299
Published
Modified

Description

The device directly executes .patch firmware upgrade files on a USB stick without any prior authentication in the admin interface. This leads to an unauthenticated code execution via the firmware upgrade function.

Affected and fixed versions

Package / productAffectedFixedSource
RITTAL GmbH & Co. KG IoT Interface & CMC III Processing Unit<6.21.00.2—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2024-47944. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2024-47944.md
Affected: RITTAL GmbH & Co. KG IoT Interface & CMC III Processing Unit <6.21.00.2
Fixed in: RITTAL GmbH & Co. KG IoT Interface & CMC III Processing Unit 6.21.00.2

Steps:
1. Search this machine and project for RITTAL GmbH & Co. KG IoT Interface & CMC III Processing Unit: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2024-47944 being exploited?

There is no confirmed exploitation: CVE-2024-47944 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.54% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2024-47944?

Medium: CVSS 6.8 (v3.1, scored by CNA). Not remotely exploitable (local or adjacent access needed).

Which versions are affected by CVE-2024-47944?

RITTAL GmbH & Co. KG IoT Interface & CMC III Processing Unit <6.21.00.2.

Is there a fix for CVE-2024-47944?

Yes. Fixed in RITTAL GmbH & Co. KG IoT Interface & CMC III Processing Unit 6.21.00.2. Upgrade IoT Interface & CMC III Processing Unit to 6.21.00.2 or later.

How do I check if I'm affected by CVE-2024-47944?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors