CVE-2024-47407
mySCADA myPRO OS Command Injection
Mitigation
- Upgrade myPRO Manager to 1.3 or later.
- Upgrade myPRO Runtime to 9.2.1 or later.
Who should check
- Anyone running mySCADA myPRO Manager < 1.3
- Anyone running mySCADA myPRO Runtime < 9.2.1
Vulnerability facts
- Affected
- mySCADA myPRO Manager < 1.3; mySCADA myPRO Runtime < 9.2.1
- Fixed in
- mySCADA myPRO Manager 1.3, mySCADA myPRO Runtime 9.2.1
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, no login needed
- CVSS
- 10.0 (v4.0, CNA)CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:HOpen in CVSS calculator
Show all 11 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Attack requirements: None
- Privileges required: None
- User interaction: None
- Confidentiality impact: High
- Integrity impact: High
- Availability impact: High
- Confidentiality impact on other systems: High
- Integrity impact on other systems: High
- Availability impact on other systems: High
- EPSS
- 5.53% chance of exploitation in 30 days (percentile 94, 2026-11-26)
- CWE
- CWE-78
- Modified
Description
A parameter within a command does not properly validate input within myPRO Manager which could be exploited by an unauthenticated remote attacker to inject arbitrary operating system commands.
Affected and fixed versions
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2024-47407. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2024-47407.md Affected: mySCADA myPRO Manager < 1.3; mySCADA myPRO Runtime < 9.2.1 Fixed in: mySCADA myPRO Manager 1.3, mySCADA myPRO Runtime 9.2.1 Steps: 1. Search this machine and project for mySCADA myPRO Manager, mySCADA myPRO Runtime: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2024-47407 being exploited?
There is no confirmed exploitation: CVE-2024-47407 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 5.53% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2024-47407?
Critical: CVSS 10.0 (v4.0, scored by CNA). Remote, no login needed.
Which versions are affected by CVE-2024-47407?
mySCADA myPRO Manager < 1.3; mySCADA myPRO Runtime < 9.2.1.
Is there a fix for CVE-2024-47407?
Yes. Fixed in mySCADA myPRO Manager 1.3, mySCADA myPRO Runtime 9.2.1. Upgrade myPRO Manager to 1.3 or later. Upgrade myPRO Runtime to 9.2.1 or later.
How do I check if I'm affected by CVE-2024-47407?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.