# CVE-2024-4622: alpitronic Hypercharger EV Charger Use of Default Credentials

> Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

- **Severity:** HIGH 8.3
- **CVSS:** 8.3 (v4.0, CNA) `CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:L/VI:N/VA:H/SC:N/SI:N/SA:N`
- **CVSS metrics:** Attack vector: Network; Attack complexity: Low; Attack requirements: Present; Privileges required: None; User interaction: None; Confidentiality impact: Low; Integrity impact: None; Availability impact: High; Confidentiality impact on other systems: None; Integrity impact on other systems: None; Availability impact on other systems: None
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** None known
- **Remote exploitation:** Remote, no login needed
- **EPSS:** 0.86% (percentile 56, 2026-11-26)
- **CWE:** CWE-1392
- **Published:** 2024-05-15T16:54:08.150Z
- **Modified:** 2026-06-17T08:02:17.063Z

## Who should check

- Anyone running alpitronic Hypercharger EV Charger all versions

## Description

If misconfigured, alpitronic Hypercharger EV charging devices can expose a web interface 
protected by authentication. If the default credentials are not changed,
 an attacker can use public knowledge to access the device as an 
administrator.

## Affected and fixed versions

- alpitronic Hypercharger EV Charger: all versions (cvelist)

## Mitigation

- Vendor workaround: alpitronic recommends users change the default credentials for all charging devices.
- 
- 
- alpitronic advises that the interface should be connected only to 
- internal segregated and access-controlled networks and not exposed to 
- the public internet/web.
- 
- 
- When informed of these vulnerabilities, alpitronic, in conjunction 
- with and/or on behalf of affected clients, disabled the interface on any
-  exposed devices and all clients were contacted directly and reminded 
- that the interface is not intended to be visible on the public Internet 
- and that default passwords should be changed.
- 
- 
- alpitronic are also applying mitigations to all devices in the field 
- and to new devices in production. New devices will come with unique 
- passwords. Devices using the default password will be automatically 
- assigned new unique passwords, or at first access if the device has not 
- yet been installed. Devices with the default passwords already changed 
- will not be affected. New passwords can be obtained by scanning the 
- QR-Code inside the charger or in DMS portal hyperdoc. Contact 
- Hypercharger support with any questions about newly assigned passwords.

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2024-4622. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2024-4622.md
Affected: alpitronic Hypercharger EV Charger all versions
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for alpitronic Hypercharger EV Charger: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2024-4622 being exploited?

There is no confirmed exploitation: CVE-2024-4622 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.86% chance of exploitation in the next 30 days (as of 2026-11-26).

### How serious is CVE-2024-4622?

High: CVSS 8.3 (v4.0, scored by CNA). Remote, no login needed.

### Which versions are affected by CVE-2024-4622?

alpitronic Hypercharger EV Charger all versions.

### Is there a fix for CVE-2024-4622?

No fixed version is listed in the sources yet. Vendor workaround: alpitronic recommends users change the default credentials for all charging devices.   alpitronic advises that the interface should be connected only to  internal segregated and access-controlled networks and not exposed to  the public internet/web.   When informed of these vulnerabilities, alpitronic, in conjunction  with and/or on behalf of affected clients, disabled the interface on any  exposed devices and all clients were contacted directly and reminded  that the interface is not intended to be visible on the public Internet  and that default passwords should be changed.   alpitronic are also applying mitigations to all devices in the field  and to new devices in production. New devices will come with unique  passwords. Devices using the default password will be automatically  assigned new unique passwords, or at first access if the device has not  yet been installed. Devices with the default passwords already changed  will not be affected. New passwords can be obtained by scanning the  QR-Code inside the charger or in DMS portal hyperdoc. Contact  Hypercharger support with any questions about newly assigned passwords.

### How do I check if I'm affected by CVE-2024-4622?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- other: <https://www.cisa.gov/news-events/ics-advisories/icsa-24-130-02>
- other: <https://industrydecarbonization.com/news/insecure-password-allowed-administrative-access-to-electric-vehicle-chargers.html>

## Attribution

- CVE Program: CVE® is a registered trademark of The MITRE Corporation. CVE records © 1999–2026 The MITRE Corporation. <https://www.cve.org/Legal/TermsOfUse>
- NVD: This product uses data from the NVD API but is not endorsed or certified by the NVD. <https://nvd.nist.gov/vuln/detail/CVE-2024-4622>

HTML: <https://flawdb.com/CVE-2024-4622> · JSON: <https://flawdb.com/api/v1/entries/CVE-2024-4622>