CVE-2024-45825
5015-U8IHFT Denial-of-Service Vulnerability via CIP Message
Mitigation
- Vendor workaround: Block communication to CIP classes 883 and 67 if it is not required
Who should check
- Anyone running Rockwell Automation 5015-U8IHFT 1.011-1.012
Vulnerability facts
- Affected
- Rockwell Automation 5015-U8IHFT 1.011-1.012
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, no login needed
- CVSS
- 8.7 (v4.0, CNA)CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:NOpen in CVSS calculator
Show all 11 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Attack requirements: None
- Privileges required: None
- User interaction: None
- Confidentiality impact: None
- Integrity impact: None
- Availability impact: High
- Confidentiality impact on other systems: None
- Integrity impact on other systems: None
- Availability impact on other systems: None
- EPSS
- 1.00% chance of exploitation in 30 days (percentile 62, 2026-11-26)
- CWE
- CWE-20
- Modified
Description
CVE-2024-45825 IMPACT A denial-of-service vulnerability exists in the affected products. The vulnerability occurs when a malformed CIP packet is sent over the network to the device and results in a major nonrecoverable fault causing a denial-of-service.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Rockwell Automation 5015-U8IHFT | 1.011-1.012 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2024-45825. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2024-45825.md Affected: Rockwell Automation 5015-U8IHFT 1.011-1.012 Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Rockwell Automation 5015-U8IHFT: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2024-45825 being exploited?
There is no confirmed exploitation: CVE-2024-45825 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 1.00% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2024-45825?
High: CVSS 8.7 (v4.0, scored by CNA). Remote, no login needed.
Which versions are affected by CVE-2024-45825?
Rockwell Automation 5015-U8IHFT 1.011-1.012.
Is there a fix for CVE-2024-45825?
No fixed version is listed in the sources yet. Vendor workaround: Block communication to CIP classes 883 and 67 if it is not required
How do I check if I'm affected by CVE-2024-45825?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.