Skip to content
FlawDB
Sign in
Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

CVE-2024-44102

CRITICAL 10.0EPSS 79%

A vulnerability has been identified in PP TeleControl Server Basic 1000 to 5000 V3.1 (6NH9910-0AA31-0AE1) (All versions…

Mitigation

  • No fix listed yet: follow the vendor advisory.

Who should check

  • Anyone running Siemens PP TeleControl Server Basic 1000 to 5000 V3.1 < V3.1.2.1
  • Anyone running Siemens PP TeleControl Server Basic 256 to 1000 V3.1 < V3.1.2.1
  • Anyone running Siemens PP TeleControl Server Basic 32 to 64 V3.1 < V3.1.2.1
  • Anyone running Siemens PP TeleControl Server Basic 64 to 256 V3.1 < V3.1.2.1
  • Anyone running Siemens PP TeleControl Server Basic 8 to 32 V3.1 < V3.1.2.1
  • Anyone running Siemens TeleControl Server Basic 1000 V3.1 < V3.1.2.1
  • Anyone running Siemens TeleControl Server Basic 256 V3.1 < V3.1.2.1
  • Anyone running Siemens TeleControl Server Basic 32 V3.1 < V3.1.2.1

Vulnerability facts

Affected
Siemens PP TeleControl Server Basic 1000 to 5000 V3.1 < V3.1.2.1; Siemens PP TeleControl Server Basic 256 to 1000 V3.1 < V3.1.2.1; Siemens PP TeleControl Server Basic 32 to 64 V3.1 < V3.1.2.1; Siemens PP TeleControl Server Basic 64 to 256 V3.1 < V3.1.2.1; Siemens PP TeleControl Server Basic 8 to 32 V3.1 < V3.1.2.1; Siemens TeleControl Server Basic 1000 V3.1 < V3.1.2.1; Siemens TeleControl Server Basic 256 V3.1 < V3.1.2.1; Siemens TeleControl Server Basic 32 V3.1 < V3.1.2.1; Siemens TeleControl Server Basic 5000 V3.1 < V3.1.2.1; Siemens TeleControl Server Basic 64 V3.1 < V3.1.2.1; Siemens TeleControl Server Basic 8 V3.1 < V3.1.2.1; Siemens TeleControl Server Basic Serv Upgr < V3.1.2.1; Siemens TeleControl Server Basic Upgr V3.1 < V3.1.2.1
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Remote, no login needed
CVSS
10.0 (v4.0, CNA)CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:HOpen in CVSS calculator
Show all 11 CVSS metrics
  • Attack vector: Network
  • Attack complexity: Low
  • Attack requirements: None
  • Privileges required: None
  • User interaction: None
  • Confidentiality impact: High
  • Integrity impact: High
  • Availability impact: High
  • Confidentiality impact on other systems: High
  • Integrity impact on other systems: High
  • Availability impact on other systems: High
EPSS
1.78% chance of exploitation in 30 days (percentile 79, 2026-11-26)
CWE
CWE-502
Published
Modified

Description

A vulnerability has been identified in PP TeleControl Server Basic 1000 to 5000 V3.1 (6NH9910-0AA31-0AE1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 256 to 1000 V3.1 (6NH9910-0AA31-0AD1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 32 to 64 V3.1 (6NH9910-0AA31-0AF1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 64 to 256 V3.1 (6NH9910-0AA31-0AC1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 8 to 32 V3.1 (6NH9910-0AA31-0AB1) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 1000 V3.1 (6NH9910-0AA31-0AD0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 256 V3.1 (6NH9910-0AA31-0AC0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 32 V3.1 (6NH9910-0AA31-0AF0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 5000 V3.1 (6NH9910-0AA31-0AE0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 64 V3.1 (6NH9910-0AA31-0AB0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 8 V3.1 (6NH9910-0AA31-0AA0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic Serv Upgr (6NH9910-0AA31-0GA1) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic Upgr V3.1 (6NH9910-0AA31-0GA0) (All versions < V3.1.2.1 with redundancy configured). The affected system allows remote users to send maliciously crafted objects. Due to insecure deserialization of user-supplied content by the affected software, an unauthenticated attacker could exploit this vulnerability by sending a maliciously crafted serialized object. This could allow the attacker to execute arbitrary code on the device with SYSTEM privileges.

Affected and fixed versions

Package / productAffectedFixedSource
Siemens PP TeleControl Server Basic 1000 to 5000 V3.1< V3.1.2.1—cvelist
Siemens PP TeleControl Server Basic 256 to 1000 V3.1< V3.1.2.1—cvelist
Siemens PP TeleControl Server Basic 32 to 64 V3.1< V3.1.2.1—cvelist
Siemens PP TeleControl Server Basic 64 to 256 V3.1< V3.1.2.1—cvelist
Siemens PP TeleControl Server Basic 8 to 32 V3.1< V3.1.2.1—cvelist
Siemens TeleControl Server Basic 1000 V3.1< V3.1.2.1—cvelist
Siemens TeleControl Server Basic 256 V3.1< V3.1.2.1—cvelist
Siemens TeleControl Server Basic 32 V3.1< V3.1.2.1—cvelist
Siemens TeleControl Server Basic 5000 V3.1< V3.1.2.1—cvelist
Siemens TeleControl Server Basic 64 V3.1< V3.1.2.1—cvelist
Siemens TeleControl Server Basic 8 V3.1< V3.1.2.1—cvelist
Siemens TeleControl Server Basic Serv Upgr< V3.1.2.1—cvelist
Siemens TeleControl Server Basic Upgr V3.1< V3.1.2.1—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2024-44102. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2024-44102.md
Affected: Siemens PP TeleControl Server Basic 1000 to 5000 V3.1 < V3.1.2.1; Siemens PP TeleControl Server Basic 256 to 1000 V3.1 < V3.1.2.1; Siemens PP TeleControl Server Basic 32 to 64 V3.1 < V3.1.2.1; Siemens PP TeleControl Server Basic 64 to 256 V3.1 < V3.1.2.1; Siemens PP TeleControl Server Basic 8 to 32…
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Siemens PP TeleControl Server Basic 1000 to 5000 V3.1, Siemens PP TeleControl Server Basic 256 to 1000 V3.1, Siemens PP TeleControl Server Basic 32 to 64 V3.1, Siemens PP TeleControl Server Basic 64 to 256 V3.1, Siemens PP TeleControl Server Basic 8 to 32 V3.1, Siemens TeleControl Server Basic 1000…: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2024-44102 being exploited?

There is no confirmed exploitation: CVE-2024-44102 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 1.78% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2024-44102?

Critical: CVSS 10.0 (v4.0, scored by CNA). Remote, no login needed.

Which versions are affected by CVE-2024-44102?

Siemens PP TeleControl Server Basic 1000 to 5000 V3.1 < V3.1.2.1; Siemens PP TeleControl Server Basic 256 to 1000 V3.1 < V3.1.2.1; Siemens PP TeleControl Server Basic 32 to 64 V3.1 < V3.1.2.1; Siemens PP TeleControl Server Basic 64 to 256 V3.1 < V3.1.2.1; Siemens PP TeleControl Server Basic 8 to 32 V3.1 < V3.1.2.1; Siemens TeleControl Server Basic 1000 V3.1 < V3.1.2.1; Siemens TeleControl Server Basic 256 V3.1 < V3.1.2.1; Siemens TeleControl Server Basic 32 V3.1 < V3.1.2.1; Siemens TeleControl Server Basic 5000 V3.1 < V3.1.2.1; Siemens TeleControl Server Basic 64 V3.1 < V3.1.2.1; Siemens TeleControl Server Basic 8 V3.1 < V3.1.2.1; Siemens TeleControl Server Basic Serv Upgr < V3.1.2.1; Siemens TeleControl Server Basic Upgr V3.1 < V3.1.2.1.

Is there a fix for CVE-2024-44102?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

How do I check if I'm affected by CVE-2024-44102?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors