CVE-2024-43663
Buffer overflow vulnerabilities in CGI scripts lead to segfault
Mitigation
- Upgrade Iocharger firmware for AC models to 24120701 or later.
Who should check
- Anyone running Iocharger firmware for AC models < 24120701
Vulnerability facts
- Affected
- Iocharger firmware for AC models < 24120701
- Fixed in
- Iocharger firmware for AC models 24120701
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, login needed
- CVSS
- 5.3 (v4.0, CNA)CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N/AU:Y/R:AOpen in CVSS calculator
Show all 13 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Attack requirements: None
- Privileges required: Low
- User interaction: None
- Confidentiality impact: None
- Integrity impact: None
- Availability impact: Low
- Confidentiality impact on other systems: None
- Integrity impact on other systems: None
- Availability impact on other systems: None
- AU: Y
- R: A
- EPSS
- 2.12% chance of exploitation in 30 days (percentile 83, 2026-11-26)
- CWE
- CWE-121
- Modified
Description
There are many buffer overflow vulnerabilities present in several CGI binaries of the charging station.This issue affects Iocharger firmware for AC model chargers beforeversion 24120701. Likelihood: High – Given the prevalence of these buffer overflows, and the clear error message of the web server, an attacker is very likely to be able to find these vulnerabilities. Impact: Low – Usually, overflowing one of these buffers just causes a segmentation fault of the CGI binary, which causes the web server to return a 502 Bad Gateway error. However the webserver itself is not affected, and no DoS can be achieved. Abusing these buffer overflows in a meaningful way requires highly technical knowledge, especially since ASLR also seems to be enabled on the charging station. However, a skilled attacker might be able to use one of these buffer overflows to obtain remote code execution. CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). The attack has a small impact on the availability of the device (VC:N/VI:N/VA:L). There is no impact on subsequent systems. (SC:N/SI:N/SA:N). While this device is an EV charger handing significant amounts of power, we do not expect this vulnerability to have a safety impact. The attack can be automated (AU:Y).
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Iocharger firmware for AC models | < 24120701 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2024-43663. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2024-43663.md Affected: Iocharger firmware for AC models < 24120701 Fixed in: Iocharger firmware for AC models 24120701 Steps: 1. Search this machine and project for Iocharger firmware for AC models: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2024-43663 being exploited?
There is no confirmed exploitation: CVE-2024-43663 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 2.12% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2024-43663?
Medium: CVSS 5.3 (v4.0, scored by CNA). Remote, login needed.
Which versions are affected by CVE-2024-43663?
Iocharger firmware for AC models < 24120701.
Is there a fix for CVE-2024-43663?
Yes. Fixed in Iocharger firmware for AC models 24120701. Upgrade Iocharger firmware for AC models to 24120701 or later.
How do I check if I'm affected by CVE-2024-43663?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.