HIGH 7.1EPSS 53%

Buffer overflow in <redacted>.so leads to DoS of OCPP service

Mitigation

  • Upgrade Iocharger firmware for AC models to 24120701 or later.

Who should check

  • Anyone running Iocharger firmware for AC models < 24120701

Vulnerability facts

Affected
Iocharger firmware for AC models < 24120701
Fixed in
Iocharger firmware for AC models 24120701
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Remote, login needed
CVSS
7.1 (v4.0, CNA)CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/AU:Y/R:IOpen in CVSS calculator
Show all 13 CVSS metrics
  • Attack vector: Network
  • Attack complexity: Low
  • Attack requirements: None
  • Privileges required: Low
  • User interaction: None
  • Confidentiality impact: None
  • Integrity impact: None
  • Availability impact: High
  • Confidentiality impact on other systems: None
  • Integrity impact on other systems: None
  • Availability impact on other systems: None
  • AU: Y
  • R: I
EPSS
0.79% chance of exploitation in 30 days (percentile 53, 2026-11-26)
CWE
CWE-121
Published
Modified

Description

The <redacted>.so library, which is used by <redacted>, is vulnerable to a buffer overflow in the code that handles the deletion of certificates. This buffer overflow can be triggered by providing a long file path to the <redacted> action of the <redacted>.exe CGI binary or to the <redacted>.sh CGI script. This binary or script will write this file path to <redacted>, which is then read by <redacted>.so This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – An attacker will have to find this exploit by either obtaining the binaries involved in this vulnerability, or by trial and error. Furthermore, the attacker will need a (low privilege) account to gain access to the <redacted>.exe CGI binary or <redacted>.sh script to trigger the vulnerability, or convince a user with such access send an HTTP request that triggers it. Impact: High – The <redacted> process, which we assume is responsible for OCPP communication, will keep crashing after performing the exploit. This happens because the buffer overflow causes the process to segfault before <redacted> is removed. This means that, even though <redacted> is automatically restarted, it will crash again as soon as it tries to parse the text file. CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). The attack leads to reducred availability of the device (VC:N/VI:N/VA:H). THere is not impact on subsequent systems. (SC:N/SI:N/SA:N). Alltough this device is an EV charger handing significant amounts of power, we do not forsee a safety impact. The attack can be automated (AU:Y). Because the DoS condition is written to disk persistantly, it cannot be recovered by the user (R:I).

Affected and fixed versions

Package / productAffectedFixedSource
Iocharger firmware for AC models< 24120701—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2024-43661. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2024-43661.md
Affected: Iocharger firmware for AC models < 24120701
Fixed in: Iocharger firmware for AC models 24120701

Steps:
1. Search this machine and project for Iocharger firmware for AC models: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2024-43661 being exploited?

There is no confirmed exploitation: CVE-2024-43661 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.79% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2024-43661?

High: CVSS 7.1 (v4.0, scored by CNA). Remote, login needed.

Which versions are affected by CVE-2024-43661?

Iocharger firmware for AC models < 24120701.

Is there a fix for CVE-2024-43661?

Yes. Fixed in Iocharger firmware for AC models 24120701. Upgrade Iocharger firmware for AC models to 24120701 or later.

How do I check if I'm affected by CVE-2024-43661?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors