Skip to content
FlawDB
Sign in
Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

CVE-2024-43660

HIGH 7.1EPSS 56%

Arbitrary file download using <redacted>.sh

Mitigation

  • Upgrade Iocharger firmware for AC models to 24120701 or later.

Who should check

  • Anyone running Iocharger firmware for AC models < 24120701

Vulnerability facts

Affected
Iocharger firmware for AC models < 24120701
Fixed in
Iocharger firmware for AC models 24120701
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Remote, login needed
CVSS
7.1 (v4.0, CNA)CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/AU:YOpen in CVSS calculator
Show all 12 CVSS metrics
  • Attack vector: Network
  • Attack complexity: Low
  • Attack requirements: None
  • Privileges required: Low
  • User interaction: None
  • Confidentiality impact: High
  • Integrity impact: None
  • Availability impact: None
  • Confidentiality impact on other systems: None
  • Integrity impact on other systems: None
  • Availability impact on other systems: None
  • AU: Y
EPSS
0.86% chance of exploitation in 30 days (percentile 56, 2026-11-26)
CWE
CWE-552
Published
Modified

Description

The CGI script <redacted>.sh can be used to download any file on the filesystem. This issue affects Iocharger firmware for AC model chargers beforeversion 24120701. Likelihood: High, but credentials required. Impact: Critical – The script can be used to download any file on the filesystem, including sensitive files such as /etc/shadow, the CGI script source code or binaries and configuration files. CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/S:P/AU:Y CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). The confidentiality of all files of the devicd can be compromised (VC:H/VI:N/VA:N). There is no impact on subsequent systems. (SC:N/SI:N/SA:N). While this device is an EV charger handing significant amounts of power, this attack in isolation does not have a safety impact. The attack can be automated (AU:Y).

Affected and fixed versions

Package / productAffectedFixedSource
Iocharger firmware for AC models< 24120701—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2024-43660. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2024-43660.md
Affected: Iocharger firmware for AC models < 24120701
Fixed in: Iocharger firmware for AC models 24120701

Steps:
1. Search this machine and project for Iocharger firmware for AC models: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2024-43660 being exploited?

There is no confirmed exploitation: CVE-2024-43660 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.86% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2024-43660?

High: CVSS 7.1 (v4.0, scored by CNA). Remote, login needed.

Which versions are affected by CVE-2024-43660?

Iocharger firmware for AC models < 24120701.

Is there a fix for CVE-2024-43660?

Yes. Fixed in Iocharger firmware for AC models 24120701. Upgrade Iocharger firmware for AC models to 24120701 or later.

How do I check if I'm affected by CVE-2024-43660?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors