CVE-2024-43655
Any authenticated users can execute OS commands as root using the <redacted>.sh CGI script.
Mitigation
- Upgrade Iocharger firmware for AC models to 24120701 or later.
Who should check
- Anyone running Iocharger firmware for AC models < 24120701
Vulnerability facts
- Affected
- Iocharger firmware for AC models < 24120701
- Fixed in
- Iocharger firmware for AC models 24120701
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, login needed
- CVSS
- 9.3 (v4.0, CNA)CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H/S:P/AU:YOpen in CVSS calculator
Show all 13 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Attack requirements: None
- Privileges required: Low
- User interaction: None
- Confidentiality impact: High
- Integrity impact: High
- Availability impact: High
- Confidentiality impact on other systems: Low
- Integrity impact on other systems: Low
- Availability impact on other systems: High
- S: P
- AU: Y
- EPSS
- 2.54% chance of exploitation in 30 days (percentile 86, 2026-11-26)
- CWE
- CWE-78, CWE-250
- Modified
Description
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Iocharger firmware for AC models | < 24120701 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2024-43655. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2024-43655.md Affected: Iocharger firmware for AC models < 24120701 Fixed in: Iocharger firmware for AC models 24120701 Steps: 1. Search this machine and project for Iocharger firmware for AC models: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2024-43655 being exploited?
There is no confirmed exploitation: CVE-2024-43655 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 2.54% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2024-43655?
Critical: CVSS 9.3 (v4.0, scored by CNA). Remote, login needed.
Which versions are affected by CVE-2024-43655?
Iocharger firmware for AC models < 24120701.
Is there a fix for CVE-2024-43655?
Yes. Fixed in Iocharger firmware for AC models 24120701. Upgrade Iocharger firmware for AC models to 24120701 or later.
How do I check if I'm affected by CVE-2024-43655?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.