CVE-2024-43650

CRITICAL 9.3EPSS 88%

Authenticated command injection in the <redacted> action leads to full remote code execution as root on the charging station

Mitigation

  • Upgrade Iocharger firmware for AC models to 24120701 or later.

Who should check

  • Anyone running Iocharger firmware for AC models < 24120701

Vulnerability facts

Affected
Iocharger firmware for AC models < 24120701
Fixed in
Iocharger firmware for AC models 24120701
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Remote, login needed
CVSS
9.3 (v4.0, CNA)CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H/S:P/AU:YOpen in CVSS calculator
Show all 13 CVSS metrics
  • Attack vector: Network
  • Attack complexity: Low
  • Attack requirements: None
  • Privileges required: Low
  • User interaction: None
  • Confidentiality impact: High
  • Integrity impact: High
  • Availability impact: High
  • Confidentiality impact on other systems: Low
  • Integrity impact on other systems: Low
  • Availability impact on other systems: High
  • S: P
  • AU: Y
EPSS
3.08% chance of exploitation in 30 days (percentile 88, 2026-11-26)
CWE
CWE-78, CWE-250
Published
Modified

Description

Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects  firmware versions before 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: The attack can be executed over any network connection serving the web interface (AV:N). There are no additional measures that need to be circumvented (AC:L) or attack preconditions (AT:N). THe attack is privileged, but the level does not matter (PR:L) and does not require user interaction (UI:N). Attack leads to full system compromised (VC:H/VI:H/VA:H) and compromised devices can be used to "pivot" to other networks that should be unreachable (SC:L/SI:L/SA:H). Because this an EV charger using high power, there is a potential safety impact (S:P). The attack can be automated (AU:Y).

Affected and fixed versions

Package / productAffectedFixedSource
Iocharger firmware for AC models< 24120701—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2024-43650. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2024-43650.md
Affected: Iocharger firmware for AC models < 24120701
Fixed in: Iocharger firmware for AC models 24120701

Steps:
1. Search this machine and project for Iocharger firmware for AC models: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2024-43650 being exploited?

There is no confirmed exploitation: CVE-2024-43650 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 3.08% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2024-43650?

Critical: CVSS 9.3 (v4.0, scored by CNA). Remote, login needed.

Which versions are affected by CVE-2024-43650?

Iocharger firmware for AC models < 24120701.

Is there a fix for CVE-2024-43650?

Yes. Fixed in Iocharger firmware for AC models 24120701. Upgrade Iocharger firmware for AC models to 24120701 or later.

How do I check if I'm affected by CVE-2024-43650?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors