CVE-2024-42512
Security Update for the OPC UA .NET Standard Stack
Also known as GHSA-h958-fxgg-g7w3
Mitigation
- Upgrade OPCFoundation.NetStandard.Opc.Ua.Core to 1.5.374.158 or later.
Who should check
- Projects that depend on NuGet package OPCFoundation.NetStandard.Opc.Ua.Core (< 1.5.374.158)
- Anyone running n/a (versions: see the vendor advisory)
- Anyone running Siemens SIMATIC Energy Manager PRO V7.2 < *
- Anyone running Siemens SIMATIC Energy Manager PRO V7.3 < *
- Anyone running Siemens SIMATIC Energy Manager PRO V7.4 >= V7.4 Update 0, < V7.4 Update 7
- Anyone running Siemens SIMATIC Energy Manager PRO V7.5 >= V7.5 Update 0, < V7.5 Update 2
- Anyone running Siemens SIMIT V11 < V11.3
Vulnerability facts
- Affected
- OPCFoundation.NetStandard.Opc.Ua.Core < 1.5.374.158
- Fixed in
- 1.5.374.158
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, no login needed
- CVSS
- 8.6 (v3.1, CNA)CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:LOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Privileges required: None
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: High
- Integrity impact: Low
- Availability impact: Low
- EPSS
- 0.73% chance of exploitation in 30 days (percentile 50, 2026-11-26)
- CWE
- CWE-208
- Modified
Description
Vulnerability in the OPC UA .NET Standard Stack before 1.5.374.158 allows an unauthorized attacker to bypass application authentication when the deprecated Basic128Rsa15 security policy is enabled.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| NuGet OPCFoundation.NetStandard.Opc.Ua.Core | < 1.5.374.158 | 1.5.374.158 | osv |
| n/a | — | — | nvd |
| Siemens SIMATIC Energy Manager PRO V7.2 | < * | — | nvd |
| Siemens SIMATIC Energy Manager PRO V7.3 | < * | — | nvd |
| Siemens SIMATIC Energy Manager PRO V7.4 | >= V7.4 Update 0, < V7.4 Update 7 | — | nvd |
| Siemens SIMATIC Energy Manager PRO V7.5 | >= V7.5 Update 0, < V7.5 Update 2 | — | nvd |
| Siemens SIMIT V11 | < V11.3 | — | nvd |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2024-42512. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2024-42512.md Affected: OPCFoundation.NetStandard.Opc.Ua.Core < 1.5.374.158 Fixed in: 1.5.374.158 Steps: 1. Search this machine and project for OPCFoundation.NetStandard.Opc.Ua.Core (NuGet), n/a, Siemens SIMATIC Energy Manager PRO V7.2, Siemens SIMATIC Energy Manager PRO V7.3, Siemens SIMATIC Energy Manager PRO V7.4, Siemens SIMATIC Energy Manager PRO V7.5: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
Vendor advisories
Patches
FAQ
Is CVE-2024-42512 being exploited?
There is no confirmed exploitation: CVE-2024-42512 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.73% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2024-42512?
High: CVSS 8.6 (v3.1, scored by CNA). Remote, no login needed.
Which versions are affected by CVE-2024-42512?
OPCFoundation.NetStandard.Opc.Ua.Core < 1.5.374.158.
Is there a fix for CVE-2024-42512?
Yes. Fixed in 1.5.374.158. Upgrade OPCFoundation.NetStandard.Opc.Ua.Core to 1.5.374.158 or later.
How do I check if I'm affected by CVE-2024-42512?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.