CVE-2024-41996
Validating the order of the public keys in the Diffie-Hellman Key Agreement Protocol, when an approved safe prime is us…
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running n/a (versions: see the vendor advisory)
- Anyone running diffie-hellman_key_exchange_project diffie-hellman_key_exchange <= *
- Anyone running Siemens RUGGEDCOM RST2428P < V3.3
- Anyone running Siemens SCALANCE XC-300/XR-300/XC-400/XR-500WG/XR-500 family < V3.3
- Anyone running Siemens SCALANCE XCH328 < V3.3
- Anyone running Siemens SCALANCE XCM324 < V3.3
- Anyone running Siemens SCALANCE XCM328 < V3.3
- Anyone running Siemens SCALANCE XCM332 < V3.3
Vulnerability facts
- Affected
- n/a; diffie-hellman_key_exchange_project diffie-hellman_key_exchange <= *; Siemens RUGGEDCOM RST2428P < V3.3; Siemens SCALANCE XC-300/XR-300/XC-400/XR-500WG/XR-500 family < V3.3; Siemens SCALANCE XCH328 < V3.3; Siemens SCALANCE XCM324 < V3.3; Siemens SCALANCE XCM328 < V3.3; Siemens SCALANCE XCM332 < V3.3; Siemens SCALANCE XRH334 (24 V DC, 8xFO, CC) < V3.3; Siemens SCALANCE XRM334 (230 V AC, 12xFO) < V3.3; Siemens SCALANCE XRM334 (230 V AC, 8xFO) < V3.3; Siemens SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) < V3.3; Siemens SCALANCE XRM334 (24 V DC, 12xFO) < V3.3; Siemens SCALANCE XRM334 (24 V DC, 8xFO) < V3.3; Siemens SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) < V3.3; Siemens SCALANCE XRM334 (2x230 V AC, 12xFO) < V3.3; Siemens SCALANCE XRM334 (2x230 V AC, 8xFO) < V3.3; Siemens SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) < V3.3; Siemens SIDIS Prime < V4.0.800; Siemens SIMATIC S7-1500 TM MFP - GNU/Linux subsystem < V1.1.1
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, no login needed
- CVSS
- 7.5 (v3.1, CNA)CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Privileges required: None
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: None
- Integrity impact: None
- Availability impact: High
- EPSS
- 1.54% chance of exploitation in 30 days (percentile 75, 2026-11-26)
- CWE
- CWE-295
- Modified
Description
Validating the order of the public keys in the Diffie-Hellman Key Agreement Protocol, when an approved safe prime is used, allows remote attackers (from the client side) to trigger unnecessarily expensive server-side DHE modular-exponentiation calculations. The client may cause asymmetric resource consumption. The basic attack scenario is that the client must claim that it can only communicate with DHE, and the server must be configured to allow DHE and validate the order of the public key.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| n/a | — | — | nvd |
| diffie-hellman_key_exchange_project diffie-hellman_key_exchange | <= * | — | nvd |
| Siemens RUGGEDCOM RST2428P | < V3.3 | — | nvd |
| Siemens SCALANCE XC-300/XR-300/XC-400/XR-500WG/XR-500 family | < V3.3 | — | nvd |
| Siemens SCALANCE XCH328 | < V3.3 | — | nvd |
| Siemens SCALANCE XCM324 | < V3.3 | — | nvd |
| Siemens SCALANCE XCM328 | < V3.3 | — | nvd |
| Siemens SCALANCE XCM332 | < V3.3 | — | nvd |
| Siemens SCALANCE XRH334 (24 V DC, 8xFO, CC) | < V3.3 | — | nvd |
| Siemens SCALANCE XRM334 (230 V AC, 12xFO) | < V3.3 | — | nvd |
| Siemens SCALANCE XRM334 (230 V AC, 8xFO) | < V3.3 | — | nvd |
| Siemens SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) | < V3.3 | — | nvd |
| Siemens SCALANCE XRM334 (24 V DC, 12xFO) | < V3.3 | — | nvd |
| Siemens SCALANCE XRM334 (24 V DC, 8xFO) | < V3.3 | — | nvd |
| Siemens SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) | < V3.3 | — | nvd |
| Siemens SCALANCE XRM334 (2x230 V AC, 12xFO) | < V3.3 | — | nvd |
| Siemens SCALANCE XRM334 (2x230 V AC, 8xFO) | < V3.3 | — | nvd |
| Siemens SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) | < V3.3 | — | nvd |
| Siemens SIDIS Prime | < V4.0.800 | — | nvd |
| Siemens SIMATIC S7-1500 TM MFP - GNU/Linux subsystem | < V1.1.1 | — | nvd |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2024-41996. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2024-41996.md Affected: n/a; diffie-hellman_key_exchange_project diffie-hellman_key_exchange <= *; Siemens RUGGEDCOM RST2428P < V3.3; Siemens SCALANCE XC-300/XR-300/XC-400/XR-500WG/XR-500 family < V3.3; Siemens SCALANCE XCH328 < V3.3; Siemens SCALANCE XCM324 < V3.3; Siemens SCALANCE XCM328 < V3.3; Siemens SCALANCE XCM332 … Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for n/a, diffie-hellman_key_exchange_project diffie-hellman_key_exchange, Siemens RUGGEDCOM RST2428P, Siemens SCALANCE XC-300/XR-300/XC-400/XR-500WG/XR-500 family, Siemens SCALANCE XCH328, Siemens SCALANCE XCM324: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
Other
- https://gist.github.com/c0r0n3r/abccc14d4d96c0442f3a77fa5ca255d1
- https://dheatattack.gitlab.io/details/
- https://dheatattack.gitlab.io/faq/
- https://cert-portal.siemens.com/productcert/html/ssa-265688.html
- https://cert-portal.siemens.com/productcert/html/ssa-089022.html
- https://cert-portal.siemens.com/productcert/html/ssa-485750.html
FAQ
Is CVE-2024-41996 being exploited?
There is no confirmed exploitation: CVE-2024-41996 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 1.54% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2024-41996?
High: CVSS 7.5 (v3.1, scored by CNA). Remote, no login needed.
Which versions are affected by CVE-2024-41996?
n/a; diffie-hellman_key_exchange_project diffie-hellman_key_exchange <= *; Siemens RUGGEDCOM RST2428P < V3.3; Siemens SCALANCE XC-300/XR-300/XC-400/XR-500WG/XR-500 family < V3.3; Siemens SCALANCE XCH328 < V3.3; Siemens SCALANCE XCM324 < V3.3; Siemens SCALANCE XCM328 < V3.3; Siemens SCALANCE XCM332 < V3.3; Siemens SCALANCE XRH334 (24 V DC, 8xFO, CC) < V3.3; Siemens SCALANCE XRM334 (230 V AC, 12xFO) < V3.3; Siemens SCALANCE XRM334 (230 V AC, 8xFO) < V3.3; Siemens SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) < V3.3; Siemens SCALANCE XRM334 (24 V DC, 12xFO) < V3.3; Siemens SCALANCE XRM334 (24 V DC, 8xFO) < V3.3; Siemens SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) < V3.3; Siemens SCALANCE XRM334 (2x230 V AC, 12xFO) < V3.3; Siemens SCALANCE XRM334 (2x230 V AC, 8xFO) < V3.3; Siemens SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) < V3.3; Siemens SIDIS Prime < V4.0.800; Siemens SIMATIC S7-1500 TM MFP - GNU/Linux subsystem < V1.1.1.
Is there a fix for CVE-2024-41996?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2024-41996?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.