CVE-2024-41927
Cleartext transmission of sensitive information vulnerability exists in multiple IDEC PLCs. If an attacker sends a spec…
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running IDEC Corporation FC6A Series MICROSmart All-in-One CPU module Ver.2.60 and earlier
- Anyone running IDEC Corporation FC6B Series MICROSmart All-in-One CPU module Ver.2.60 and earlier
- Anyone running IDEC Corporation FC6A Series MICROSmart Plus CPU module Ver.2.40 and earlier
- Anyone running IDEC Corporation FC6B Series MICROSmart Plus CPU module Ver.2.60 and earlier
- Anyone running IDEC Corporation FT1A Series SmartAXIS Pro/Lite Ver.2.41 and earlier
Vulnerability facts
- Affected
- IDEC Corporation FC6A Series MICROSmart All-in-One CPU module Ver.2.60 and earlier; IDEC Corporation FC6B Series MICROSmart All-in-One CPU module Ver.2.60 and earlier; IDEC Corporation FC6A Series MICROSmart Plus CPU module Ver.2.40 and earlier; IDEC Corporation FC6B Series MICROSmart Plus CPU module Ver.2.60 and earlier; IDEC Corporation FT1A Series SmartAXIS Pro/Lite Ver.2.41 and earlier
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Not remotely exploitable (local or adjacent access needed)
- CVSS
- 4.6 (v3.1, CNA)CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:NOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Physical
- Attack complexity: Low
- Privileges required: None
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: High
- Integrity impact: None
- Availability impact: None
- EPSS
- 0.23% chance of exploitation in 30 days (percentile 8, 2026-11-26)
- CWE
- CWE-319
- Modified
Description
Cleartext transmission of sensitive information vulnerability exists in multiple IDEC PLCs. If an attacker sends a specific command to PLC's serial communication port, user credentials may be obtained. As a result, the program of the PLC may be obtained, and the PLC may be manipulated.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| IDEC Corporation FC6A Series MICROSmart All-in-One CPU module | Ver.2.60 and earlier | — | cvelist |
| IDEC Corporation FC6B Series MICROSmart All-in-One CPU module | Ver.2.60 and earlier | — | cvelist |
| IDEC Corporation FC6A Series MICROSmart Plus CPU module | Ver.2.40 and earlier | — | cvelist |
| IDEC Corporation FC6B Series MICROSmart Plus CPU module | Ver.2.60 and earlier | — | cvelist |
| IDEC Corporation FT1A Series SmartAXIS Pro/Lite | Ver.2.41 and earlier | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2024-41927. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2024-41927.md Affected: IDEC Corporation FC6A Series MICROSmart All-in-One CPU module Ver.2.60 and earlier; IDEC Corporation FC6B Series MICROSmart All-in-One CPU module Ver.2.60 and earlier; IDEC Corporation FC6A Series MICROSmart Plus CPU module Ver.2.40 and earlier; IDEC Corporation FC6B Series MICROSmart Plus CPU modu… Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for IDEC Corporation FC6A Series MICROSmart All-in-One CPU module, IDEC Corporation FC6B Series MICROSmart All-in-One CPU module, IDEC Corporation FC6A Series MICROSmart Plus CPU module, IDEC Corporation FC6B Series MICROSmart Plus CPU module, IDEC Corporation FT1A Series SmartAXIS Pro/Lite: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2024-41927 being exploited?
There is no confirmed exploitation: CVE-2024-41927 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.23% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2024-41927?
Medium: CVSS 4.6 (v3.1, scored by CNA). Not remotely exploitable (local or adjacent access needed).
Which versions are affected by CVE-2024-41927?
IDEC Corporation FC6A Series MICROSmart All-in-One CPU module Ver.2.60 and earlier; IDEC Corporation FC6B Series MICROSmart All-in-One CPU module Ver.2.60 and earlier; IDEC Corporation FC6A Series MICROSmart Plus CPU module Ver.2.40 and earlier; IDEC Corporation FC6B Series MICROSmart Plus CPU module Ver.2.60 and earlier; IDEC Corporation FT1A Series SmartAXIS Pro/Lite Ver.2.41 and earlier.
Is there a fix for CVE-2024-41927?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2024-41927?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.