CVE-2024-34397
An issue was discovered in GNOME GLib before 2.78.5, and 2.79.x and 2.80.x before 2.80.1. When a GDBus-based client sub…
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running n/a (versions: see the vendor advisory)
- Anyone running Siemens RUGGEDCOM RST2428P < V3.1
- Anyone running Siemens SCALANCE XC-300/XR-300/XC-400/XR-500WG/XR-500 family (versions: see the vendor advisory)
- Anyone running Siemens SCALANCE XCM-/XRM-/XCH-/XRH-300 family < V3.1
- Anyone running Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP MFP >= V3.1.5, < *
- Anyone running Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP >= V3.1.5, < *
- Anyone running Siemens SIPLUS S7-1500 CPU 1518-4 PN/DP MFP >= V3.1.5, < *
Vulnerability facts
- Affected
- n/a; Siemens RUGGEDCOM RST2428P < V3.1; Siemens SCALANCE XC-300/XR-300/XC-400/XR-500WG/XR-500 family; Siemens SCALANCE XCM-/XRM-/XCH-/XRH-300 family < V3.1; Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP MFP >= V3.1.5, < *; Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP MFP >= V3.1.5, < *; Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP >= V3.1.5, < *; Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP >= V3.1.5, < *; Siemens SIPLUS S7-1500 CPU 1518-4 PN/DP MFP >= V3.1.5, < *
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- Yes: see the exploit references below
- Remote exploitation
- Not remotely exploitable (local or adjacent access needed)
- CVSS
- 5.2 (v3.1, CNA)CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:LOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Physical
- Attack complexity: Low
- Privileges required: None
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: None
- Integrity impact: High
- Availability impact: Low
- EPSS
- 1.18% chance of exploitation in 30 days (percentile 68, 2026-11-26)
- CWE
- CWE-290
- Modified
Description
An issue was discovered in GNOME GLib before 2.78.5, and 2.79.x and 2.80.x before 2.80.1. When a GDBus-based client subscribes to signals from a trusted system service such as NetworkManager on a shared computer, other users of the same computer can send spoofed D-Bus signals that the GDBus-based client will wrongly interpret as having been sent by the trusted system service. This could lead to the GDBus-based client behaving incorrectly, with an application-dependent impact.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| n/a | — | — | nvd |
| Siemens RUGGEDCOM RST2428P | < V3.1 | — | nvd |
| Siemens SCALANCE XC-300/XR-300/XC-400/XR-500WG/XR-500 family | — | — | nvd |
| Siemens SCALANCE XCM-/XRM-/XCH-/XRH-300 family | < V3.1 | — | nvd |
| Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP MFP | >= V3.1.5, < * | — | nvd |
| Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP MFP | >= V3.1.5, < * | — | nvd |
| Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP | >= V3.1.5, < * | — | nvd |
| Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP | >= V3.1.5, < * | — | nvd |
| Siemens SIPLUS S7-1500 CPU 1518-4 PN/DP MFP | >= V3.1.5, < * | — | nvd |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2024-34397. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2024-34397.md Affected: n/a; Siemens RUGGEDCOM RST2428P < V3.1; Siemens SCALANCE XC-300/XR-300/XC-400/XR-500WG/XR-500 family; Siemens SCALANCE XCM-/XRM-/XCH-/XRH-300 family < V3.1; Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP MFP >= V3.1.5, < *; Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP MFP >= V3.1.5, < *; Siemens SIMATIC S7-1… Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for n/a, Siemens RUGGEDCOM RST2428P, Siemens SCALANCE XC-300/XR-300/XC-400/XR-500WG/XR-500 family, Siemens SCALANCE XCM-/XRM-/XCH-/XRH-300 family, Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP MFP, Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
Vendor advisories
- https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/IRSFYAE5X23TNRWX7ZWEJOMISLCDSYNS/
- https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/UNFJHISR4O6VFOHBFWH5I5WWMG37H63A/
- https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/LL6HSJDXCXMLEIJBYV6CPOR4K2NTCTXW/
- https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/LCDY3KA7G7D3DRXYTT46K6LFHS2KHWBH/
Exploits and PoCs
Other
- https://www.openwall.com/lists/oss-security/2024/05/07/5
- https://lists.debian.org/debian-lts-announce/2024/05/msg00008.html
- https://security.netapp.com/advisory/ntap-20240531-0008/
- https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/IRSFYAE5X23TNRWX7ZWEJOMISLCDSYNS/
- https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/UNFJHISR4O6VFOHBFWH5I5WWMG37H63A/
- https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/LCDY3KA7G7D3DRXYTT46K6LFHS2KHWBH/
- https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/LL6HSJDXCXMLEIJBYV6CPOR4K2NTCTXW/
- https://cert-portal.siemens.com/productcert/html/ssa-082556.html
- https://cert-portal.siemens.com/productcert/html/ssa-613116.html
FAQ
Is CVE-2024-34397 being exploited?
There is no confirmed exploitation: CVE-2024-34397 is not in the CISA Known Exploited Vulnerabilities catalog. Public exploit code or a proof of concept is available. EPSS estimates a 1.18% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2024-34397?
Medium: CVSS 5.2 (v3.1, scored by CNA). Not remotely exploitable (local or adjacent access needed).
Which versions are affected by CVE-2024-34397?
n/a; Siemens RUGGEDCOM RST2428P < V3.1; Siemens SCALANCE XC-300/XR-300/XC-400/XR-500WG/XR-500 family; Siemens SCALANCE XCM-/XRM-/XCH-/XRH-300 family < V3.1; Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP MFP >= V3.1.5, < *; Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP MFP >= V3.1.5, < *; Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP >= V3.1.5, < *; Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP >= V3.1.5, < *; Siemens SIPLUS S7-1500 CPU 1518-4 PN/DP MFP >= V3.1.5, < *.
Is there a fix for CVE-2024-34397?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2024-34397?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.