CVE-2024-32754
Johnson Controls Kantech KT1, KT2, and KT400 Door Controllers - Exposure of Sensitive Information
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Johnson Controls Kantech KT1 Door Controller, Rev01 <= 2.09.10
- Anyone running Johnson Controls Kantech KT2 Door Controller, Rev01 <= 2.09.10
- Anyone running Johnson Controls Kantech KT400 Door Controller, Rev01 <= 3.01.16
Vulnerability facts
- Affected
- Johnson Controls Kantech KT1 Door Controller, Rev01 <= 2.09.10; Johnson Controls Kantech KT2 Door Controller, Rev01 <= 2.09.10; Johnson Controls Kantech KT400 Door Controller, Rev01 <= 3.01.16
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Not remotely exploitable (local or adjacent access needed)
- CVSS
- 3.1 (v3.1, CNA)CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:NOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Adjacent network
- Attack complexity: High
- Privileges required: None
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: Low
- Integrity impact: None
- Availability impact: None
- EPSS
- 0.30% chance of exploitation in 30 days (percentile 16, 2026-11-26)
- CWE
- CWE-200
- Modified
Description
Under certain circumstances, when the controller is in factory reset mode waiting for initial setup, it will broadcast its MAC address, serial number, and firmware version. Once configured, the controller will no longer broadcast this information.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Johnson Controls Kantech KT1 Door Controller, Rev01 | <= 2.09.10 | — | cvelist |
| Johnson Controls Kantech KT2 Door Controller, Rev01 | <= 2.09.10 | — | cvelist |
| Johnson Controls Kantech KT400 Door Controller, Rev01 | <= 3.01.16 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2024-32754. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2024-32754.md Affected: Johnson Controls Kantech KT1 Door Controller, Rev01 <= 2.09.10; Johnson Controls Kantech KT2 Door Controller, Rev01 <= 2.09.10; Johnson Controls Kantech KT400 Door Controller, Rev01 <= 3.01.16 Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Johnson Controls Kantech KT1 Door Controller, Rev01, Johnson Controls Kantech KT2 Door Controller, Rev01, Johnson Controls Kantech KT400 Door Controller, Rev01: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2024-32754 being exploited?
There is no confirmed exploitation: CVE-2024-32754 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.30% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2024-32754?
Low: CVSS 3.1 (v3.1, scored by CNA). Not remotely exploitable (local or adjacent access needed). The attack needs conditions outside the attacker's control, which makes it harder.
Which versions are affected by CVE-2024-32754?
Johnson Controls Kantech KT1 Door Controller, Rev01 <= 2.09.10; Johnson Controls Kantech KT2 Door Controller, Rev01 <= 2.09.10; Johnson Controls Kantech KT400 Door Controller, Rev01 <= 3.01.16.
Is there a fix for CVE-2024-32754?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2024-32754?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.