Skip to content
FlawDB
Sign in
Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

CVE-2024-12054

MEDIUM 5.9EPSS 23%

ZF Roll Stability Support Plus (RSSPlus) Authentication Bypass By Primary Weakness

Mitigation

  • Upgrade RSSPlus 2M to 01/23 or later.
  • Vendor workaround: To most effectively mitigate general vulnerabilities of the powerline
  • communication, any trucks, trailers, and tractors utilizing J2497
  • technology should disable all features where possible, except for
  • backwards-compatibility with LAMP ON detection only. Users acquiring new
  • trailer equipment should migrate all diagnostics to newer trailer bus
  • technology. Users acquiring new tractor equipment should remove support
  • for reception of any J2497 message other than LAMP messages.

Who should check

  • Anyone running ZF RSSPlus 2M >= 01/08, < 01/23

Vulnerability facts

Affected
ZF RSSPlus 2M >= 01/08, < 01/23
Fixed in
ZF RSSPlus 2M 01/23
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Not remotely exploitable (local or adjacent access needed)
CVSS
5.9 (v4.0, CNA)CVSS:4.0/AV:A/AC:H/AT:P/PR:N/UI:P/VC:N/VI:L/VA:H/SC:N/SI:N/SA:NOpen in CVSS calculator
Show all 11 CVSS metrics
  • Attack vector: Adjacent network
  • Attack complexity: High
  • Attack requirements: Present
  • Privileges required: None
  • User interaction: Passive
  • Confidentiality impact: None
  • Integrity impact: Low
  • Availability impact: High
  • Confidentiality impact on other systems: None
  • Integrity impact on other systems: None
  • Availability impact on other systems: None
EPSS
0.37% chance of exploitation in 30 days (percentile 23, 2026-11-26)
CWE
CWE-305
Published
Modified

Description

ZF Roll Stability Support Plus (RSSPlus) is vulnerable to an authentication bypass vulnerability targeting deterministic RSSPlus SecurityAccess service seeds, which may allow an attacker to remotely (proximal/adjacent with RF equipment or via pivot from J2497 telematics devices) call diagnostic functions intended for workshop or repair scenarios. This can impact system availability, potentially degrading performance or erasing software, however the vehicle remains in a safe vehicle state.

Affected and fixed versions

Package / productAffectedFixedSource
ZF RSSPlus 2M>= 01/08, < 01/23—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2024-12054. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2024-12054.md
Affected: ZF RSSPlus 2M >= 01/08, < 01/23
Fixed in: ZF RSSPlus 2M 01/23

Steps:
1. Search this machine and project for ZF RSSPlus 2M: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2024-12054 being exploited?

There is no confirmed exploitation: CVE-2024-12054 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.37% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2024-12054?

Medium: CVSS 5.9 (v4.0, scored by CNA). Not remotely exploitable (local or adjacent access needed). A user has to take an action, such as opening a link, for the attack to work. The attack needs conditions outside the attacker's control, which makes it harder.

Which versions are affected by CVE-2024-12054?

ZF RSSPlus 2M >= 01/08, < 01/23.

Is there a fix for CVE-2024-12054?

Yes. Fixed in ZF RSSPlus 2M 01/23. Upgrade RSSPlus 2M to 01/23 or later. Vendor workaround: To most effectively mitigate general vulnerabilities of the powerline communication, any trucks, trailers, and tractors utilizing J2497 technology should disable all features where possible, except for backwards-compatibility with LAMP ON detection only. Users acquiring new trailer equipment should migrate all diagnostics to newer trailer bus technology. Users acquiring new tractor equipment should remove support for reception of any J2497 message other than LAMP messages.

How do I check if I'm affected by CVE-2024-12054?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors